Drug stability test boxFeatures
1. 7-inch large touch screen, with digital display of temperature inside the box, set temperature, humidity inside the box, set humidity, lighting value, Beijing time, running time, heating status, cooling status, dehumidification status, humidification status, door opening and closing status, password lock status, lighting status and other indicators on the same large screen.
2. Electrostatic spray coating shell, mirror stainless steel inner liner.
3. 0-99 time periods can be automatically switched at will, and can also be switched to day or night mode. The light intensity can be adjusted by adjusting the LED strip light level. (Optional LED top mounted light source, infinite dimming)
4. Standard embedded printer.
5. The instrument can store 250000 pieces of historical data internally and view data and curves in real-time.
6. The instrument can record the changes in various parameters internally, which is suitable for quality certification data recording and fault diagnosis. All data can be downloaded and stored through a USB flash drive; It can also be directly connected to a computer to synchronously monitor the experimental process or record experimental data.
7. Horizontal circulating wind ensures consistent temperature between layers after placing items.
8. Equipped with an independent temperature limit alarm system, it automatically interrupts when the temperature limit is exceeded, ensuring safe operation of the experiment and preventing accidents.
9. The inner liner protection temperature can be set, and if it is higher than the inner liner protection temperature, the software and hardware will automatically cut off the power to protect the test sample.
10. Automatic warning of instrument malfunction.
Drug stability test boxTechnical Specifications
Temperature control range: 0 ° C to 70 ° C
Temperature resolution: 0.1 ℃
Temperature fluctuation: ± 0.5 ℃
Humidity control range: 20-98% RH
Humidity resolution: 0.1% RH
Humidity fluctuation: ± 3% RH
Illuminance: 0-10000LX
Light level: 0-5 levels
Cooling power: 190W-480W (power varies depending on the model)
Working environment: 0-30 ℃, humidity below 85% RH, no corrosive gases
Compressor delay protection time: 3 minutes.
★ Storage conditions for long-term stability testing of retained samples
Temperature:+25 ℃± 2 ℃
Humidity: 60 ± 5% RH
Time: 12 months
★ Storage conditions for accelerated stability testing
Temperature:+40 ℃± 2 ℃
Humidity: 75 ± 5% RH
Time: 6 months
Strong light irradiation conditions: Illumination level: 4500 ± 500LX
model |
volume |
Overall dimensions mm |
Temperature control range |
temperature fluctuation |
Moisture control range |
Humidity fluctuation |
illuminance |
LBY-260SD |
260L |
600*670*1650 |
0-70℃ |
±0.5℃ |
20-98%RH |
±3%RH |
0-10000LX (customizable strong light 30000LX) |
LBY-350SD |
350L |
600*670*1918 |
|||||
LBY-450SD |
450L |
720*670*1918 |
|||||
LBY-1000SD |
1000L |
1350*670*1918 |