Domestic ultra micro spectrophotometers usually refer to a very small concentration range of substances, between nanoKelvin and picoKelvin. Specifically, trace amounts refer to chemical substances or elements with concentrations ranging from 1 to 100 picomoles per liter (pg/mL).
Functions of domestic ultra micro spectrophotometer:
UV detection: detect the absorbance value of the sample at conventional UV wavelengths;
Nucleic acid testing: It can detect the concentration of different types of nucleic acids such as dsDNA, ssDNA, RNA, and their absorbance values at 260nm and 280nm;
Probe detection: detecting the absorbance value of fluorescently labeled probes, which can be used to remove samples that have not been labeled with probes;
Protein detection: detect the concentration of purified protein and the absorbance at 280nm, and perform quantitative analysis of BCA, Bradford, Lowry, Pierce 660nm proteins;
Bacterial solution/suspended cell concentration detection: can detect the OD600 value of bacterial solution and monitor the growth of suspended cells;
Dynamics detection: used for measuring enzyme activity and growth curves in kinetic experiments;
Full wavelength scanning: 185-910nm full wavelength scanning, displaying absorption curve;
User defined detection: The detection parameters can be customized, such as large absorption peak, calculation formula, etc.
Small detection volume of 0.5 μ L, saving precious samples
Achieve an optical path accuracy of 0.001mm and achieve high repeatability in absorbance detection
High concentration samples can be measured directly without dilution, and real-time detection results will be displayed within 5 seconds
Wide Range - Large Measurable~15000ng/μ L dSDNA, Continuous Wavelength Range 185-910nm
More convenient - paired with a high-resolution tablet to achieve local one finger control
More friendly - WiFi wireless connection function, saving time and space
Parameters of domestic ultra micro spectrophotometer
A. Ultra micro pedestal mode:
1. Wavelength range: 185-910nm
2. Sample size: 0.5 μ l
3. Wavelength accuracy: 1nm
4. Resolution:<1.8 nm (FWHM at Hg 253.7 nm)
5. Optical path length: 1mm optical path length (can be automatically adjusted to 0.05mm)
6. Detection limit: 2ng/μ l (dsDNA)
7. Detection limit: 15000ng/μ l (dsDNA)
8. Absorption accuracy: 0.002Abs (1mm optical path)
9. Absorption accuracy: 3% (0.65Abs @ 350nm)
10. Absorption range: 0.02-300 (equivalent to a 10mm optical path)
11. Nucleic acid testing cycle:<5s
B. Colorimetric dish mode:
1. Beam height: 8.5 mm
2. Accurate temperature control: 37 ± 0.5 ° C
3. Mixing speed: 150-850 rpm
4. Four optical paths: 1, 2, 5, 10mm respectively
5. Absorption range: 0.002-1.5
6. Detection limit: 0.4 ng/μ l (dsDNA)
7. Detection limit: 750 ng/μ l (dsDNA)