E-mail
823645566@qq.com
-
Phone
13806141376,13901490282
-
Address
170 Huacheng Middle Road, Jintan City, Jiangsu Province
Changzhou Jintan Precision Instrument Equipment Co., Ltd
823645566@qq.com
13806141376,13901490282
170 Huacheng Middle Road, Jintan City, Jiangsu Province
Digital water bath oscillator, water bath constant temperature oscillator is a biochemical instrument that combines a temperature controlled constant temperature box and a speed regulating multi-purpose oscillator. It is mainly suitable for the oscillation cultivation of various liquid and solid compounds such as biology, biochemistry, cells, bacteria, etc. in various universities, medical, petrochemical, health and epidemic prevention, environmental monitoring and other scientific research departments
Digital water bath oscillator 1Digital water bath oscillatorTechnical parameters: model SHA-CA SHZ-82A SHA-B Temperature range Room temperature -100 ℃ Room temperature -100 ℃ Room temperature -100 ℃ Temp Accuracy ±0.5℃ ±0.5℃ ±0.5℃ Power 1800W 1800W 1800W speed range Start at -300 revolutions per minute Start at -300 revolutions per minute Start at -300 revolutions per minute Oscillation move back and forth Convolute bifunctional Amplitude 20mm 20mm 20mm
Digital water bath oscillatortime range 0-9999min (or normally open) 0-9999min (or normally open) 0-9999min (or normally open) External dimensions 700×550×490 700×550×490 700×550×490 IIDigital water bath oscillatorProduct features: 1. Temperature control range: room temperature -100 degrees. 2. Temperature control method: using microcomputer temperature control, temperature control * *, no overheating or overshoot phenomenon. 3. Oscillatory mode: dual functions of round-trip and cyclotron. 4. Inner liner material: High grade stainless steel, universal spring clamp, and different clamps can also be designed according to requirements. 5Digital water bath oscillatorShell material: The surface of the high-quality cold plate is electrostatically sprayed with plastic for rust prevention and extended service life. 6. Motor type: Permanent magnet DC motor, small size, high power, long service life, and also has the characteristics of low noise. 7. Speed regulation method: stepless speed regulation. 8. Timing range: 0-9999 minutes or normally open. 9. Temperature and speed dual digital display. Note: The digital water bath oscillator should be cleaned promptly after each use to extend its service life. Digital water bath oscillator IIIDigital water bath oscillatorusage method: 1. Firstly, add water to the water tank, then bottle the reagent onto the oscillation rack and clamp it with a spring. Connect the power supply and turn on the power switch. The speed regulator will light up, and then turn on the heating switch. Click the SET function button on the temperature controller to set the temperature. The upper row will display the set temperature, and the lower row will display SP. Click the ↑ or ↓ button to adjust the desired working temperature. If you need to adjust quickly, you can use the ← button to quickly set it. After setting, click the SET function button again. The upper row will display the timing time, and the lower row will display ST. Click the ↑ or ↓ button to select the timing time. If timing is not needed, set the time to 0. Click the set button again to exit the setting state. At this time, the temperature inside the box will Run at the set temperature. 2. Select the corresponding oscillation mode, where "-" represents the spiral oscillation mode and "=" represents the reciprocating oscillation mode. Choose the corresponding oscillation mode as needed, click the "OR" button on the speed/time controller to select the oscillation speed, and then click the M and H buttons to select the timing time (M minutes, H hours). After setting, click the run button to start running. If you want to stop, click the stop button. 3. After use, turn off the power. If not in use for a long time, please unplug the power. If there are water droplets inside the box, please clean and wipe them clean in a timely manner to extend the service life. 4Digital water bath oscillatormatters needing attention: 1. All technical indicators of this series of products have undergone actual operation inspection before leaving the factory. If the user needs to use a self provided thermometer (with certain accuracy) for measurement due to process requirements, the user's thermometer shall prevail. If there is a difference between the displayed value of the temperature control instrument and the thermometer, the user can adjust the internal parameters of the temperature control instrument slightly to meet the process requirements.
2. When using, water must be added first and then electricity must be turned on. Dry burning is strictly prohibited.
3. When in use, there must be a reliable grounding to ensure safety.
4. If the water level is lower than the electric heating tube, it is not allowed to use it with electricity to prevent the electric heating tube from bursting and being damaged.
5. The water level should not be too high to prevent water from overflowing into the electrical box and damaging components.
6. Regularly check whether the screws of each contact are loose, and if they are loose, tighten them to maintain good contact of each electrical contact.
7. When not in use for a long time, the water in the sink should be drained and wiped clean, and the scale in the sink should be regularly removed.
8. If any abnormal working phenomenon occurs, it should be checked and repaired in a timely manner. If the fault cannot be accurately determined, contact the company's technical department