Product Introduction: The digital anemometer is used to measure wind speed. The power supply is 9V (006P) * 1, and the battery current consumption is 10mA. The working temperature/humidity is -10 ℃~50 ℃/85% (Z atmospheric working pressure is 500Mb-2bar). The display mode is 3 1/2, and the LCD display size is 168mm * 90mm * 31.3mm. The weight is 500g
Product Details

Digital anemometer

anemometer

gear

measurement range

resolution

error

M/S

0.3-45.0

0.1

± 3% or 0.1 digits

KNOTS

0.6-88.0

0.1

± 3% or 0.1 digits

ft/min

60-8800

10

± 3% or 10 digits

Km/hr

1-140.0

0.1

± 3% or 0.1 digits

temperature(AVM-03)

0-60

0.1

± 0.8

temperature(AVM-03)

32-140

0.1

± 1.5



Power supply 9V (006P) * 1 battery
Current consumption 10mA
Working temperature/humidity -10 ℃~50 ℃/85% (maximum)
Working pressure 500Mb-2bar
Display mode 3 1/2 digit LCD display
Size 168mm * 90mm * 31.3mm
Weight 500g

MODEL AVM05/AVM07
Airflow (CFM, CMM)
Instantaneous, average, 2/3 maximum airflow measurement
Wind speed m/s, ft/min, knots, Km/hr, mph
LCD dual display
Temperature measurement ℃/℉ switching
RS-232 connection computer transmission (AVM07)
AVM05/AVM07


Specification AVM05/AVM07 (23 oC+/-5 oC)

Digital anemometerMeasurement range of wind speed:

unit

gear

resolution

Threshold

accuracy

m/s

0.0~45.0

0.1

0.3

±3%±0.1dgts

ft/min

0.0~8800

0.1/1

60

±3%±10dgts

knots

0.0~88.0

0.1

0.6

±3%±0.1dgts

km/hr-

0.0~140.0

0.1

1.0

±3%±0.1dgts

mph

0.0~100.0

0..1

0.7

±3%±0.1dgts

M/s: meters/second ft/min: feet/minute
Knots: nautical miles per hour Km/hr: kilometers per hour
Mph: miles per hour
Wind speed testing range (CMM): 0.01~9999 m2Airflow testing range (CMM): 0.01~9999 x 100
(CFM) : 0.01~9999 ft2(CFM) : 0.01~9999 x 100
Wind temperature range:

unit

gear

resolution

accuracy

0.0~45.0

0.2

+/-1.0oC

32.0~113.0

0.36

+/-1.8oC

General specifications:

battery

9V square

display

2 x 4 four digit dual display LCD

bearing

Artificial gemstone bearings

temperature sensor

K-type thermocouple

Operating temperature

Table: 0oC~ 50oC ( 32oF~122oF )
Fan: 0oC~ 60oC ( 32oF~140oF )

Operating humidity

Less than 80% RH

Storage temperature

﹣40oC~ 60oC (﹣40oF~140oF)

current consumption

About 3mA

size

表: 3.46〞x 6.61〞x 1.03〞(88x168x26.2mm)
Fan: 2.60 "x 5.22" x 1.15 "(66x132x29.2mm)

weight

350g/12.34oz. (including battery)

accessories

Carrying box x 1, user manual x 1, 9V battery x 1
Disk (AVM07), RS-232 adapter

Similar products include:

41

Digital noise meter

CENT-320

30-130dB/digital display/zui large/zui small noise

2450

42

Digital noise meter

1350A

30-130dB/digital display/zui large/zui small noise

1900

43

Integral statistical sound level meter

1353

Range: 30-130dBS-232 connected to a computer to store 32000 records,

12000

44

Spectrum noise analyzer

TES-1358A

Digital display, barcode display. Lp, Leq, LE, Lmax, Lmin measurement, 1/1 and 1/3 bandpass filters, memory capacity: 12280 pens (noise meter mode) 1024 pens (1/1 and 1/3 octave analysis mode)

26000

45

High frequency near-field electric field measuring instrument

RJ-3

Frequency: 20-200MHz, Range: 0-450V/m

6000

46

Microwave leakage energy meter

RCQ-1A

Range: 10u-20mW/cm2, 3 ranges, frequency: 0.915G-12.4GHz

7800

47

Personal dosimeter

FJ-403G1

Personal dose: 0.1uSv/-9999mSv/h, equivalent rate: 0.01-99.99uSv/h

4500

48

α. β surface contamination detector

FJ-2207

α:0-9999S1,β:0-9999S1

17500

6、 Anemometer, illuminance meter, temperature and humidity meter, atmospheric pressure gauge

49

Micro wind velocimeter

BYWF-2001

High intensity probe/handheld/0.01~5m/s/reading retention, rechargeable battery

2900

50

Temperature, air volume, anemometer

AVM-

01/03/05

Wind speed: 0-45m/s, temperature: 0-60 ℃,

01 is an anemometer; 03=temperature+01; 05=air volume+03

1900/2100./

2600

51

Digital illuminance meter

TES-1330A

0.01 LUX, 0-20000 LUX/digital display

1000

52

Digital illuminance meter

TES-1332

0.1 LUX, 0-200000 LUX/digital display

1200

53

Digital illuminance meter

TES-1334A

0.01 LUX, 0-20000 LUX/digital display

1700

54

Digital illuminance meter

TES-1335A

0-40K Lux, Read value lock function, 30 minute automatic shutdown function. Zui high value and Zui low value measurement function

1900

55

Memory based illuminance meter

TES-1336A

0-20000 Lux/Fc RS-232 interface can be connected to a computer, with a maximum storage capacity of 255 sets, 146 × 70 × 39 mm

2980

56

UV illuminance meter

ZG-4A

0.1-1.999 × 10000 μ w/cm with bracket and protective goggles

2500

57

digital thermometer

CENTER307

-200 ° C to 1370 ° C, resolution of 0.1 ° C

980

58

Data storage thermometer

CENTER305

RS-232 interface, with 16000 data records in Windows software, and other indicators are the same as 307 thermometer

2600

59

thermometer

CENTER308

-200 ° C to 1370 ° C, resolution of 0.1 ° C, dual probes

980

60

Infrared thermometer

TES-1326

-20 ℃~500 ℃, resolution: 0.1 ℃

1400

61

Infrared thermometer

TES-1327

Beyond the high and low warning points, the buzzer sounds a warning, and the data is recorded, stored, and read. The rest is the same as above

1800

62

Digital temperature and humidity meter

ET2003HT

Measurement range: -40~60 ℃, 0~100RH%,

3200

63

thermo-hygrometer

CENT-310

-20~60℃0~100RH%; -20~60℃

2600

64

Data storage type temperature and humidity meter

CENT-311

Data storage function/RS232 interface/computer software/connection cable/CRT display reading, 16000 data storage

3500

65

Dual channel temperature and humidity meter

CENT-313

Dual channel temperature input, channel 1: -20 ° C~60 ° C, channel 2: -200 ° C~1370 ° C

5000

66

Storage type dual channel temperature and humidity meter

CENT-314

Capable of 311 and 313 functions

5980

67

Digital temperature and humidity meter

TES-1360

Temperature: -20 ℃~60 ℃, humidity: 10% RH~95% RH

1900

68

Dew point wet bulb thermometer and hygrometer

TES-1364

Temperature: -20 ℃~60 ℃ (-4 ℉~140 ℉)
Humidity: 10% RH~95% RH, dew point temperature measurement, wet bulb temperature measurement.

2500

69

Intelligent Dew Point Wet bulb Temperature and Humidity Meter

TES-1365

RS-232 interface and application software. The maximum and minimum measurement values include time records, and the rest are the same as above.

4500

70

Digital atmospheric pressure gauge

BY-2003P

Digital display of atmospheric pressure, range: 80-110KP, resolution: 0.1KP,

1980