Phone
18015580277
-
Address
No. 55 Dongfu Road, Suzhou Industrial Park
Suzhou Yucheng Instrument Co., Ltd
18015580277
No. 55 Dongfu Road, Suzhou Industrial Park
Digital anemometer
anemometer |
gear |
measurement range |
resolution |
error |
M/S |
0.3-45.0 |
0.1 |
± 3% or 0.1 digits |
|
KNOTS |
0.6-88.0 |
0.1 |
± 3% or 0.1 digits |
|
ft/min |
60-8800 |
10 |
± 3% or 10 digits |
|
Km/hr |
1-140.0 |
0.1 |
± 3% or 0.1 digits |
|
temperature(AVM-03) |
℃ |
0-60 |
0.1 |
± 0.8 |
temperature(AVM-03) |
℉ |
32-140 |
0.1 |
± 1.5 |
Power supply 9V (006P) * 1 battery
Current consumption 10mA
Working temperature/humidity -10 ℃~50 ℃/85% (maximum)
Working pressure 500Mb-2bar
Display mode 3 1/2 digit LCD display
Size 168mm * 90mm * 31.3mm
Weight 500g
MODEL AVM05/AVM07
Airflow (CFM, CMM)
Instantaneous, average, 2/3 maximum airflow measurement
Wind speed m/s, ft/min, knots, Km/hr, mph
LCD dual display
Temperature measurement ℃/℉ switching
RS-232 connection computer transmission (AVM07)
AVM05/AVM07
Specification AVM05/AVM07 (23 oC+/-5 oC)
|
Digital anemometerMeasurement range of wind speed:
|
M/s: meters/second ft/min: feet/minute
Knots: nautical miles per hour Km/hr: kilometers per hour
Mph: miles per hour
Wind speed testing range (CMM): 0.01~9999 m2Airflow testing range (CMM): 0.01~9999 x 100
(CFM) : 0.01~9999 ft2(CFM) : 0.01~9999 x 100
Wind temperature range:
unit |
gear |
resolution |
accuracy |
℃ |
0.0~45.0 |
0.2 |
+/-1.0oC |
℉ |
32.0~113.0 |
0.36 |
+/-1.8oC |
General specifications:
battery |
9V square |
display |
2 x 4 four digit dual display LCD |
bearing |
Artificial gemstone bearings |
temperature sensor |
K-type thermocouple |
Operating temperature |
Table: 0oC~ 50oC ( 32oF~122oF ) |
Operating humidity |
Less than 80% RH |
Storage temperature |
﹣40oC~ 60oC (﹣40oF~140oF) |
current consumption |
About 3mA |
size |
表: 3.46〞x 6.61〞x 1.03〞(88x168x26.2mm) |
weight |
350g/12.34oz. (including battery) |
accessories |
Carrying box x 1, user manual x 1, 9V battery x 1 |
Similar products include:
41 |
Digital noise meter |
CENT-320 |
30-130dB/digital display/zui large/zui small noise |
2450 |
|
42 |
Digital noise meter |
1350A |
30-130dB/digital display/zui large/zui small noise |
1900 |
|
43 |
Integral statistical sound level meter |
1353 |
Range: 30-130dBS-232 connected to a computer to store 32000 records, |
12000 |
|
44 |
Spectrum noise analyzer |
TES-1358A |
Digital display, barcode display. Lp, Leq, LE, Lmax, Lmin measurement, 1/1 and 1/3 bandpass filters, memory capacity: 12280 pens (noise meter mode) 1024 pens (1/1 and 1/3 octave analysis mode) |
26000 |
|
45 |
High frequency near-field electric field measuring instrument |
RJ-3 |
Frequency: 20-200MHz, Range: 0-450V/m |
6000 |
|
46 |
Microwave leakage energy meter |
RCQ-1A |
Range: 10u-20mW/cm2, 3 ranges, frequency: 0.915G-12.4GHz |
7800 |
|
47 |
Personal dosimeter |
FJ-403G1 |
Personal dose: 0.1uSv/-9999mSv/h, equivalent rate: 0.01-99.99uSv/h |
4500 |
|
48 |
α. β surface contamination detector |
FJ-2207 |
α:0-9999S-1,β:0-9999S-1 |
17500 |
|
6、 Anemometer, illuminance meter, temperature and humidity meter, atmospheric pressure gauge | |||||
49 |
Micro wind velocimeter |
BYWF-2001 |
High intensity probe/handheld/0.01~5m/s/reading retention, rechargeable battery |
2900 |
|
50 |
Temperature, air volume, anemometer |
AVM- 01/03/05 |
Wind speed: 0-45m/s, temperature: 0-60 ℃, 01 is an anemometer; 03=temperature+01; 05=air volume+03 |
1900/2100./ 2600 |
|
51 |
Digital illuminance meter |
TES-1330A |
0.01 LUX, 0-20000 LUX/digital display |
1000 |
|
52 |
Digital illuminance meter |
TES-1332 |
0.1 LUX, 0-200000 LUX/digital display |
1200 |
|
53 |
Digital illuminance meter |
TES-1334A |
0.01 LUX, 0-20000 LUX/digital display |
1700 |
|
54 |
Digital illuminance meter |
TES-1335A |
0-40K Lux, Read value lock function, 30 minute automatic shutdown function. Zui high value and Zui low value measurement function |
1900 |
|
55 |
Memory based illuminance meter |
TES-1336A |
0-20000 Lux/Fc RS-232 interface can be connected to a computer, with a maximum storage capacity of 255 sets, 146 × 70 × 39 mm |
2980 |
|
56 |
UV illuminance meter |
ZG-4A |
0.1-1.999 × 10000 μ w/cm with bracket and protective goggles |
2500 |
|
57 |
digital thermometer |
CENTER307 |
-200 ° C to 1370 ° C, resolution of 0.1 ° C |
980 |
|
58 |
Data storage thermometer |
CENTER305 |
RS-232 interface, with 16000 data records in Windows software, and other indicators are the same as 307 thermometer |
2600 |
|
59 |
thermometer |
CENTER308 |
-200 ° C to 1370 ° C, resolution of 0.1 ° C, dual probes |
980 |
|
60 |
Infrared thermometer |
TES-1326 |
-20 ℃~500 ℃, resolution: 0.1 ℃ |
1400 |
|
61 |
Infrared thermometer |
TES-1327 |
Beyond the high and low warning points, the buzzer sounds a warning, and the data is recorded, stored, and read. The rest is the same as above |
1800 |
|
62 |
Digital temperature and humidity meter |
ET2003HT |
|
Measurement range: -40~60 ℃, 0~100RH%, |
3200 |
63 |
thermo-hygrometer |
CENT-310 |
-20~60℃0~100RH%; -20~60℃ |
2600 |
|
64 |
Data storage type temperature and humidity meter |
CENT-311 |
Data storage function/RS232 interface/computer software/connection cable/CRT display reading, 16000 data storage |
3500 |
|
65 |
Dual channel temperature and humidity meter |
CENT-313 |
Dual channel temperature input, channel 1: -20 ° C~60 ° C, channel 2: -200 ° C~1370 ° C |
5000 |
|
66 |
Storage type dual channel temperature and humidity meter |
CENT-314 |
Capable of 311 and 313 functions |
5980 |
|
67 |
Digital temperature and humidity meter |
TES-1360 |
Temperature: -20 ℃~60 ℃, humidity: 10% RH~95% RH |
1900 |
|
68 |
Dew point wet bulb thermometer and hygrometer |
TES-1364 |
Temperature: -20 ℃~60 ℃ (-4 ℉~140 ℉) |
2500 |
|
69 |
Intelligent Dew Point Wet bulb Temperature and Humidity Meter |
TES-1365 |
RS-232 interface and application software. The maximum and minimum measurement values include time records, and the rest are the same as above. |
4500 |
|
70 |
Digital atmospheric pressure gauge |
BY-2003P |
Digital display of atmospheric pressure, range: 80-110KP, resolution: 0.1KP, |
1980 |
|