Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Vaisala DPT146 Dew Point and Pressure Transmitter DPT146 Dew Point and Pressure Transmitter * A transmitter that can simultaneously monitor dew point and process pressure, making compressed air monitoring simple and practical. The transmitter can use online pressure compensation dew point data to obtain high-precision humidity information

Product Details

Vaisala DPT146 Dew Point and Pressure Transmitter(For compressed air)
DPT146 Dew Point and Pressure Transmitter * transmitters that can simultaneously monitor dew point and process pressure
A transmitter that makes compressed air monitoring simple and user-friendly
High precision humidity information can be obtained by utilizing online pressure compensation dew point data
Mature sensor technology
Compatible with the Visa handheld DM70 instrument, it enables convenient sampling, local display, and data recording
Pressure measurement range: 1... 10 bar
Dew point measurement range: -60...+30 ° C (-76...+86 ° F), with an accuracy of ± 2 ° C (± 3.6 ° F).
Vaisala DPT146 Dew Point and Pressure TransmitterTechnical specifications

measured parameter

dew point
pressure
Temperature (when using only RS-485 port output)
Under certain circumstances)

-60 . .. +30 °C (-76 ... +86 °F)
1 . .. 10 bar (14.5 ... 145 psi)
-40 . .. +80 °C (-40 ... +176 °F)

calculation parameters

Calculate ppm moisture value by volume

1 . .. 40 000 ppm

Convert dew point to atmospheric pressure

-75 … +30 °C (-103 ... +86 °F)

performance

Dew point accuracy

±2 °C (±3.6 °F)

At a temperature of 23 ° C (73.4 ° F)
Accuracy of pressure in time
Pressure temperature dependence

±0.4 %FS

±0.1 %FS/10 °C(18°F)

temperature accuracy

0 . .. 40 °C (+32 ... +104 °F)
-40...80 °C (-40 ... +176 °F)
PPM accuracy (7 bar)

±0.5 °C (± 0.9 °F)
±1 °C (± 1.8 °F)
± (14 ppm+12% of the reading value)

Sensor response time
Pressure response time
Dew point measurement response time at 20 ° C and 1 bar is 63% [90%]
-50 -> -10 °C Tdf
-10 -> -50 °C Tdf


< 1 s


5 s [ 10 s]
10 s [ 2.5 min]

Working environment

Operating temperature of electronic devices
work pressure
relative humidity

-40 … +60 °C (-40 ... +140 °F)
0 … 50 bar (0…725 psi)
0...100 %

output

Analog output (2 channels)
current output
voltage output
Analog output accuracy
digital output
connector


0 … 20 mA, 4 … 20 mA
0 … 5V, 0 …10V
± 0.01 V / ± 0.01 mA
RS-485, Non isolated, Vaisala protocol
4-pin M8

General Information

sensor
working voltage



input current
During the normal measurement process
During the self diagnosis process
External load
Used for current output
Used for voltage output
Shell material
Shell protection level
sensor protection
Storage temperature range
Only transmitter part
transport packaging
mechanical connection
Recommended calibration cycle
Weight (ISO 1/2 ')

Vaisala MPS1 Multi Parameter Sensor
21 . .. 28 VDC, current output
20 . .. 28 VDC, Voltage output and/or use at cold temperatures (-40... -20 ° C (-40... -4 ° F) 15... 28 VDC, RS485 only

20 mA+load current
300 mA+load current

zui大500 Ohm
zui小10 kOhm
AISI316L
IP65(NEMA4)
18 μ m level filter screen AISI303


-40 . .. +80 °C(-40 ... +176 °F)
-20 . .. +80 °C(-4 ... +176 °F)
Mechanical connections ISOG1/2 ", NPT1/2", UNF3/4 "-16
2 years