Application industry: Installed on material barrels, pipelines, storage tanks, and liquid tanks through threads, flanges, and clamps, online monitoring of various chemical liquids such as DMAC, NMP, cutting fluid, emulsion, ethylene glycol, urea, ammonia water, alcohol cleaning solution, etc., including concentration%, refractive index, temperature, and other parameters;

MZ-2001 online liquid concentration, specific gravity, density detector
1、 Working principle: Sound waves produce different vibration frequencies in liquid media with different specific gravity concentrations,The frequency of vibration is detected by a piezoelectric crystal, shifted and amplified by a phase shifting and amplifying circuit, and then converted into a digital signal of specific gravity concentration by a microprocessorUnder normal circumstances, liquids of different concentrations exhibit a certain mathematical relationship between their specific gravity and concentration, according to the Lagrange interpolation algorithm (y=E1x)3+E2x2+E3x+E4, Where x is the specific gravity, y is the percentage concentration, and E1, E2, E3, and E4 are concentration conversion coefficients), convert the corresponding concentration value at a certain specific gravity value.
2、 Application industry: Installed on material barrels, pipelines, storage tanks, and liquid tanks through threads, flanges, and clamps, online monitoring of various chemical liquids such as DMAC, NMP, cutting fluid, emulsion, ethylene glycol, urea, ammonia water, alcohol cleaning solution, etc., including concentration%, refractive index, temperature, and other parameters;
Formaldehyde online measuring instrument
3、 Functional features:
1. According to the principle of optical refraction, the concentration%, refractive index, temperature and other parameters of various chemical liquids such as DMAC, NMP, cutting fluid, emulsion, ethylene glycol, urea, ammonia water, and alcohol cleaning solution can be measured online for a long time. After installation, calibration is not required;
2. Using a unique multi-point curve concentration measurement algorithm to test the concentration of various chemical liquids, compared with common two-point linear concentration measurement algorithms on the market, the multi-point curve concentration measurement algorithm has higher accuracy;
3. The instrument has a built-in temperature compensation function, which can measure the concentration of liquids at different temperatures, and can also select common liquids to measure concentration without setting any parameters;
4. The instrument comes with multiple switch signal outputs, such as concentration upper and lower limits, liquid addition and inlet pump signal contacts. Users do not need to use PLC programming for automation control. Our instrument can completely replace the work of PLC, and each part is modular. Subsequent maintenance is simple, and damaged components can be directly replaced without affecting the normal operation of other components;
5. Functions can be customized according to the specific needs of users.
4、 Technical parameters:
1. Measurement range: 0.0~80.0% (Brix)
2. Measurement accuracy and error: 0.1%, ± 0.2%
3. Measurement parameters: Brix concentration, refractive index
4. Liquid temperature range: 0-60 ℃
5. Pressure resistance: 1MPa
6. Protection level of sensor measurement part: IP67
7. Sensor material: 316L stainless steel
8. Default lead length of sensor: 2 meters
9. Display Controller: Industrial Control Computer
10. Upper and lower limit alarm control: multiple control points
11. Communication with PLC: possible
12. Signal output: default 24V switch quantity, optional 4-20mA, Modbus RTU and other outputs
Features: This sensor uses the principle of optical refraction to measure liquid concentration, which is not affected by liquid flow rate, stirring, or pressure. It is more suitable for online measurement in pipelines and sealed liquid drums
Formaldehyde online measuring instrument
5、 Specification parameters:
|
Manufacturer's brand:
|
Mayzum (accurate in seconds)
|
|
model:
|
MZ-2001 (intelligent type, tuning fork method)
|
MZ-1001 (buoyancy method)
|
|
Measurement range:
|
Liquid level range: 0-1500mm
|
Liquid level range: 0-1500mm
|
|
Specific gravity range: 0~2.2g/cm ³
|
Specific gravity range: 0~2.2g/cm ³
|
|
Concentration accuracy: 0.1~100.0%
|
Concentration range: 0.1~100.0%
|
|
Measurement accuracy:
|
Liquid level: 0.1mm
|
Liquid level accuracy: 0.1mm
|
|
Specific gravity: 0.0001g/cm ³
|
Specific gravity accuracy: 0.001g/cm ³
|
|
Concentration: 0.01%
|
Concentration range: 0.1%
|
|
Measurement error:
|
Liquid level: ± 0.1mm
|
Liquid level: ± 0.1mm
|
|
Specific gravity: ± 0.005g/cm ³
|
Specific gravity: ± 0.01g/cm ³
|
|
Concentration: ± 0.5~1%
|
Concentration: ± 1%
|
|
Reading frequency:
|
2 times/S (0.5 second reading)
|
2 times/S (0.5 second reading)
|
|
Protection level:
|
Sensor liquid measurement location IP67
|
not have
|
|
Explosion proof grade of sensor:
|
Ex d IIC T6Gb
|
not have
|
|
Probe material:
|
Hastelloy (more corrosion-resistant than 316L stainless steel)
|
304 stainless steel
|
|
Medium temperature:
|
0.0 ~ 120.0℃
|
0.0 ~ 160.0℃
|
|
Environmental temperature:
|
-40~85℃
|
|
Allowable relative humidity:
|
Within 80%
|
|
Output signal:
|
Default RS232, RS485 Modbus RTU digital quantity, optional switch quantity, 4-20mA output, etc
|
|
Power supply:
|
DC 24V,2A
|
|
Standard configuration:
|
Display controller, measuring probe
|
|
Other functions:
|
Customizable according to user needs
|