The DY-RL active transformer capacity characteristic tester is a high-precision instrument specifically designed for measuring transformer capacity and loss parameters. It can accurately measure a series of power frequency parameters such as capacity, no-load current, no-load loss, short-circuit loss, impedance voltage, etc. of various transformers.

Product Details

Product Overview

DY-RL activevoltage transformationThe transformer capacity characteristic tester is a high-precision instrument specifically designed for measuring transformer capacity and loss parameters. It can accurately measure a series of power frequency parameters such as capacity, no-load current, no-load loss, short-circuit loss, impedance voltage, etc. of various transformers.

Features

It can measure the no-load current, no-load loss, short-circuit voltage, short-circuit loss, and zero sequence impedance of various types of transformers.

It can automatically perform waveform distortion correction, temperature correction, voltage correction, and current correction. Operators only need to input the correction index meter according to the transformer type

The device can automatically calculate the corrected result, which is very suitable for units that do not have slightly larger capacity transformer short-circuit test conditions.

Allow external voltage transformers and current transformers for extended range measurement, capable of measuring any parameter of the test sample.

Voltage circuit width limit: Accuracy can be ensured without switching gears. The instrument itself will not be damaged due to incorrect voltage gear selection.

Technical Specifications

input characteristics Active part Passive part
Voltage measurement range: 0~10V

Current measurement range: 0~10A

Voltage measurement range: 0~750V.

Current measurement range: 0~100A.

accuracy Voltage, current, frequency: ± 0.2%; Power: ± 0.2% (Cos Φ>0.1), ± 0.5% (0.02<Cos Φ<0.1)
Operating Temperature -10℃~ +40℃
working power supply Communication 160V~400V
Dimensions (mm) 400(L)×320(W)×180(H)
Weight (kg) 8