- Phone
-
Address
Lane 355, Zhangye Road, Jiading District, Shanghai
Shanghai Duanyi Electric Technology Co., Ltd
Lane 355, Zhangye Road, Jiading District, Shanghai
DX8000 Off Frequency Dielectric Loss TesterIt is a high-precision testing instrument used for testing the dielectric tangent and capacitance of various high-voltage power equipment on site or in laboratories, such as power plants and substations. The instrument is an integrated structure with a built-in dielectric loss testing bridge, a variable frequency voltage regulating power supply, a step-up transformer, and SF6 high stability standard capacitors. The high-voltage source for testing is generated by the inverter inside the instrument and is used for testing the test sample after being stepped up by a transformer. The frequency can be changed to 50.0 Hz、47.5Hz\\52.5Hz、45.0Hz\\55.0Hz、60.0Hz、57.5Hz\\62.5Hz、55.0Hz\\65.0Hz, By using digital notch technology, the interference of power frequency electric fields on testing is avoided, fundamentally solving the problem of accurate measurement under strong electric field interference. It is also applicable to situations where a generator is used for power supply testing after a complete power outage. This instrument is equipped with an insulating oil cup and a temperature control device to test the dielectric loss of insulating oil.
DX8000 Off Frequency Dielectric Loss TesterIt mainly has the following characteristics:
Large LCD Chinese display
Easy to operate, the instrument is equipped with a full touch LCD display screen and a super comprehensive touch operation interface. Each process is very clear and understandable, and operators do not need additional professional training to use it. With just a gentle click, the entire measurement process can be completed, making it an ideal intelligent dielectric loss measurement device at present.
Massive storage of data
The instrument is equipped with a calendar chip and a large capacity memory, which can store 200 sets of data. It can save the test results in chronological order, view the historical records at any time, and print and output them.
Scientific and advanced data management
Instrument data can be exported through a USB flash drive and viewed and managed on any PC.
Multiple testing modes
The instrument can be tested using various methods such as internal high voltage, external high voltage, internal standard, external standard, positive connection method, reverse connection method, self-excited method, etc; Under the external standard external high-voltage positive connection method, high voltage (greater than 10kV) dielectric loss can be achieved.
Measure CVT without disassembling the high-voltage lead wire
The instrument can accurately measure the dielectric loss and capacitance values of the CVT without removing the high voltage leads of the CVT.
Measurement of C0 using CVT reverse shielding method
The instrument can use reverse shielding method to measure the dielectric loss value and capacitance value of C0 at the upper end of CVT.
High speed sampling signal
The inverters and sampling circuits inside the instrument are all digitally controlled, and the output voltage is continuously adjustable.
Multiple protection, secure and reliable
The instrument is equipped with multiple protection measures such as input voltage fluctuation, high voltage current, output short circuit, power failure, overvoltage, overcurrent, temperature, etc., ensuring the safety and reliability of the instrument. The instrument also has a grounding detection function to ensure that ungrounded equipment is not allowed to operate and start testing. On site misconnection of 380V power supply, with alarm function to protect the instrument from damage.
CVT testing in one step
This instrument can also test the dielectric loss and capacitance of fully sealed CVT (capacitive voltage transformer) C1 and C2, achieving simultaneous testing of C1 and C2. This instrument can also test the CVT ratio and voltage angle difference.
LCR fully automatic measurement
Fully automatic measurement of inductance, capacitance, and resistance, with angle display.
Main technical parameters
1 |
Terms of Use |
-10℃∽40℃ |
RH<80% |
||||
2 |
Anti interference principle |
Frequency conversion method |
|||||
3 |
Power supply |
AC 220V±10% |
Allow generator |
||||
4 |
high voltage output |
0.5KV∽10KV |
Every 0.1kV |
||||
Accuracy |
5% |
||||||
Maximum current |
200mA |
||||||
Capacity |
2000VA |
||||||
5 |
Self-excited power supply |
AC 0V∽50V/15A |
single frequency50.0HZ、60.0HZ Automatic dual frequency conversion 45.0HZ/55.0HZ 47.5HZ/52.5HZ 55.0HZ/65.0HZ 57.5HZ/62.5HZ |
||||
6 |
resolution |
tgδ: 0.001% |
Cx: 0.001pF |
||||
7 |
Accuracy |
Dielectric loss △ tg δ: ± (reading * 1.0%+0.040%) |
|||||
Capacitor △ C x: ± (reading * 1.0%+1.00PF) | |||||||
8 |
measurement range |
Dielectric loss TG δ |
unrestricted |
||||
Capacitor C x |
15pF < Cx < 300nF |
||||||
10KV |
Cx < 60nF |
||||||
5KV |
Cx< 150nF |
||||||
1KV |
Cx< 300nF |
||||||
CVT testing |
Cx< 300nF |
||||||
9 |
LCR measurement range |
Inductance L>20H (2kV) |
Resistance R>10K Ω (2kV) |
||||
LCR measurement accuracy |
1% |
Angle resolution |
0.01 |
||||
10 |
CVT ratio range |
10∽10000 |
|||||
CVT ratio accuracy |
3% |
CVT ratio resolution |
0.01 |
||||
11 |
Dimensions (Host (mm) |
350(L)×270(W)×315(H) |
|||||
Dimensions (Attachment) (mm) |
350(L)×270(W)×160(H) |
||||||
12 |
Memory size |
200 sets support USB data storage |
|||||
13 |
Weight (host) |
22.75Kg |
|||||
Weight (Attachment Box) |
5.25Kg |
||||||