DSP-TL1400-1600-1400 Three Temperature Zone Tube Furnace
1、 Product Introduction
This tube furnace has three heating zones, using a double-layer shell structure and an electronic control temperature instrument. Each heating zone can perform 30 stages of programmed temperature control, phase-shift triggering, and thyristor control. The furnace is made of alumina polycrystalline fiber material, and stainless steel flanges are installed at both ends of the furnace tube. The stainless steel flanges are equipped with air nozzles, valves, and pressure gauges. When vacuuming, the vacuum degree can reach 10 degrees Celsius-3Pa, This furnace is horizontal, with three temperature zones that can be independently controlled and set to different temperatures. It is easy to use and operate. The furnace has the advantages of temperature field balance, low surface temperature, fast temperature rise and fall rate, and energy saving. It is an ideal product for universities, research institutes, and industrial and mining enterprises to conduct high-temperature atmosphere sintering, atmosphere reduction, CVD experiments, and vacuum annealing.
2、 Product advantages and features
Software control system: The furnace is equipped with communication interfaces and software, which can directly control various parameters of the furnace through a computer, and observe the PV and SV temperature values and instrument operation on the furnace from the computer. The actual heating curve of the furnace will be drawn in real time by the computer, and the temperature data at each moment can be saved and retrieved at any time. (Optional)

Open lid protection system: The furnace is equipped with a travel switch, which automatically cuts off the power when the furnace lid is opened, effectively ensuring the safety of the user.
Sealing system: The furnace tube and flange are sealed by double-layer silicone O-ring extrusion, which is easy to remove and can be repeatedly removed. It has good air tightness and can ensure that the pressure gauge pointer does not deflect for 12 hours.
Vacuum system: can be equipped with TW-1.5A vacuum pump and capable of pumping up to 10-1Pa vacuum pump or capable of pumping up to 10-4Pa imported molecular pump from Germany.
Furnace material:Using alumina fiber furnace material, it does not shed powder, has good insulation performance, high reflectivity, balanced temperature field, and strong resistance to thermal expansion and contraction.
Heating element: silicon carbon rod, silicon molybdenum rod.
Leakage protection function: The furnace is equipped with a leakage air switch, which automatically cuts off power when the furnace body leaks electricity to ensure safety during use.
Gas supply system: The furnace is equipped with a float flowmeter, and customers can control the gas flow rate through the float flowmeter or proton flowmeter (please refer to the options for details).
Flange: Adopting double ring sealing technology, it effectively improves the atmosphere of the flange. The flange is equipped with various joints, which can be connected to a resistance vacuum gauge and KF25 corrugated pipe
And it can be made into a hinged design that is easy to remove.
Flange bracket: The flange is supported by a flange bracket, effectively eliminating the stress caused by the flange bracket on the corundum pipe and extending the service life of the corundum pipe.

3、 Detailed technical parameters
model |
DSP-TL1400-1600-1400-I |
DSP-TL1400-1600-1400-II |
DSP-TL1400-1600-1400-III
|
power |
10KW |
10KW |
10KW |
Furnace tube size |
Dia 60(OD) X1500 mm |
Dia80(OD)X1500 |
Dia100(OD)X1500
|
supply voltage |
380V
|
||
Number of phases |
three-phase |
||
heating element |
**Temperature Zone Silicon Carbon Rod Second Temperature Zone: Silicon Molybdenum Rod Second Temperature Zone: Silicon Carbon Rod |
||
control mode |
40 segment temperature control program (Japan Island Electric), can be divided into 4, 2, and 1 groups of programs. If divided into 4 groups of programs, each program has 10 segments, FP93 has 6 sets of PID control, which can accurately control the low, medium, and high temperature ranges. Equipped with over temperature protection and thermocouple breaking protection, the electric furnace heating circuit will automatically cut off in case of over temperature or thermocouple breaking. The instrument is available in Fahrenheit (F) and Celsius (C) for selection Equipped with 485 communication interface Equipped with automatic shutdown function It can store multiple sets of programs and can be accessed freely when in use. |
||
Furnace material |
Alumina polycrystalline fiber approvechoose and buyImported furnace materials from Japan (when selecting imported furnace materialsAdditional payment)
Imported furnace vs domestic furnace |
||
Control accuracy |
+/- 1 ℃ |
||
trigger |
Phase shift trigger |
||
electrical equipment |
CHNT |
||
Thyristor |
106/16E Siemens AG, Germany |
||
**Three temperature zones * high temperature |
1400 ℃ |
||
**Rated temperature in the three temperature zones |
1350 ℃ |
||
| Rated temperature of the second temperature zone | 1600℃ | ||
| Rated temperature of the second temperature zone | 1550℃ | ||
heating rate |
≤ 20 ℃/Min (can be modified according to requirements) |
||
Recommended heating rate |
≤10 ℃/ Min |
||
Thermocouple model |
**Temperature Zone S * * Temperature Zone B Third Temperature Zone S |
||
**Length of the heating section in the three temperature zones |
260mm |
||
Length of heating section in the second temperature zone |
300mm |
||
| **Length of the constant temperature section in the three temperature zones | 100mm | ||
| Length of constant temperature section in the second temperature zone | 120mm | ||
|
Japan Island Electric FP93 Instrument and Computer Connection Control and Recording Software (choose and buy) |
COM to USB interface The data cable connecting the computer to the stove FP93 temperature control instrument software (download, please click) FP93 temperature control instrument software installation steps (download, please click) FP93 temperature control instrument software usage instructions (download, please click) |
||
vacuum degree |
TW-1.5A 2XZ-2 VS-0.1 Vacuum System VS High Vacuum System
1. Generally, TW-1.5A can be used for rough vacuuming and expelling the gas from the furnace tube 2. The 2XZ-2 vacuum pump can pump the vacuum degree of the tube furnace tube to around 10Pa 3. The VS-0.1 vacuum system is capable of pumping the vacuum degree inside the tube furnace to 0.1Pa (and equipped with a resistance vacuum gauge display) 4. The VS high vacuum system (composed of molecular and mechanical pumps) is capable of pumping the vacuum inside the tube furnace to 10 degrees Celsius-3 Pa. |
||
Vacuum flange |
Hinged flange (optional) can be connected to resistance vacuum gauge and KF25 corrugated pipe flange (optional) water-cooled flange (optional)
Ordinary flange sleeve flange (optional) |
||
Resistance vacuum gauge (imported from the United States) (optional) (interface KF16) |
|||
authentication |
|||
Surface temperature around |
≤45℃ |
||
| safety protection system |
The furnace body is equipped with an air switch and fuse. When the current exceeds the rated current of the air switch, the air switch will automatically trip, effectively protecting the electric furnace.
|
||