• Data center
• Industrial
• Telecommunications
• Process
Minimize operating costs through the following aspects:
-Ultra high energy efficiency up to 93.5% (VFI mode)
-The 'energy-saving tool' automatically adjusts the number of operating units to adapt to the actual load
-Compatible with natural cooling
• Simplified occupied space
• Ultra high power density (the most compact among similar products): 900kVA single unit including bypass not exceeding 3.2 meters wide
Power factor correction "clean input" rectifier (without filter), the rectifier maintains a high input power factor consistently regardless of operating conditions
Built in intelligent battery monitoring system interacts with 'charging mode' to extend battery life
• Compatible with advanced power factor loads without the need for derating
Internal fault-tolerant structure with internal redundancy and fan fault location
Intelligent embedded battery monitoring with fault location and preventive remote alarms
• Able to withstand output short circuits and overloads
• Reliable and stable parallel mode
Multi system automatic cross synchronization (ACS), optimized for use in conjunction with STS
Output isolation transformer, which can reduce the impact of zero ground (N-GND) voltage and load harmonic current on UPS inverters
Modular parallel system
Powerful centralized bypass for system expansion or redundancy
• Compatible with Tier 3 and Tier 4
• Designed for use in conjunction with downstream network and STS optimization
A control panel with a graphical display interface is more user-friendly
Equipped with a "communication slot" for inserting communication interfaces, making it easy to upgrade the operating system
The design of removable power components and box type fans effectively reduces the mean time to repair (MTTR)
All components can be operated through the front
• Convenient remote monitoring via web browser or customer's monitoring system (Internet, intranet, extranet, etc.) E
Open connectivity (Modbus/Jbus, Jbus tuning, LAN, etc.)
Intended to meet the most stringent requirements for power supply availability, flexibility, and upgrading devices
Modular parallel machine can support up to 6 units with unlimited expansion
Dual bypass makes operation more convenient
Dual channel structure and static transfer system