- Phone
-
Address
2nd Floor, Building 18, Wujing Science and Technology Park, 4999 Hongmei South Road, Minhang District, Shanghai
Shanghai Zhiqin Environmental Technology Co., Ltd
2nd Floor, Building 18, Wujing Science and Technology Park, 4999 Hongmei South Road, Minhang District, Shanghai
feature |
|
■Standard equipment, stable performance, low failure rate, and high cost-effectiveness ■The use of a new refrigeration system allows for the coexistence of energy efficiency and high performance ■Multiple operating modes (fixed value running, program running, program loop running)) ■SD card digital recording function ■Capable of conducting tests at 85 º C/85% RH ■Convenient touch operation 7-inch FT-LCD ■Standard configuration includes left and right dual lead holes (Φ 100mm) to meet the requirements of sample power on testing ■suitUsed for high temperature testing, low temperature testing, constant temperature and humidity, high and low temperature alternation, high and low temperature wet heat alternation |
■Temperature and humidity controllable range (30-98%) R.H)
It will not have low performance even when repeatedly rising and fallingThus, various experiments can be designed.
■Large range and high-precision control of temperature and humidity(20~98% R.H)*3
Can be used in the low temperature range+10 ℃, low humidity
Range of degrees20%R.H(+At 70~+85 ℃)
High precision temperature and humidity control has been achieved on a large scale.
■Suitable for continuous operation in high temperature and high humidity tests (85 º C/85% R.H)
Because it can operate stably in high temperature and high humidity environments, it controls
Electricity and water consumption are suitable for long-term continuous operation.
■*Communication ability
Basically includesRS232 C/RS485 communication serial port (communication rate 115.20Selection of 0bps Ethernetmatch
model |
DE |
||||||||||
CTH |
HLT |
CTH |
HLT |
CTH |
HLT |
CTH |
HLT |
||||
100 |
200 |
500 |
800 |
||||||||
Temperature and humidity regulation method |
Balanced temperature and humidity control method (BTHC method) |
||||||||||
Temperature regulation method |
Balanced Temperature Adjustment Method (BTC Method)) |
||||||||||
|
warm*1 degree
|
scope *2 |
LT4: -40~150℃ LT6: -60~150℃ |
|||||||||
volatility |
±0.5℃ |
||||||||||
fall time |
The average temperature throughout the entire process is 1 ℃/minute |
||||||||||
rise time |
The average temperature throughout the entire process is 1-3 ℃/minute |
||||||||||
Distribution degree |
±1℃ (-60~100℃) |
||||||||||
±2℃ (100.1~150℃) | |||||||||||
|
wet*1 degree
|
scope |
30~98%R.H*3 |
|||||||||
volatility |
±2.5%R.H |
- |
±2.5%R.H |
- |
±2.5%R.H |
- |
±3.0%R.H |
- |
|||
bias |
≤±3%R.H(湿度≥75%R.H)/≤±5%R.H(湿度≤75%R.H ) |
||||||||||
供水 |
Water supply method*4 |
Pump type water supply system |
|||||||||
Water supply tank |
20L |
||||||||||
|
material constitute component |
internal material |
Stainless steel plate (SUS304) |
|||||||||
外部材quality |
cold-rolled steel sheetPowder coating |
||||||||||
thermal insulation material |
Aerogel, polyurethane foam |
||||||||||
fan |
Impeller fan |
||||||||||
|
refrigeration system
|
compressor |
rotary |
Rotating, binary freezer |
Rotating, binary freezer |
Rotating, binary freezer |
||||||
condenser |
Air-cooled type |
Cascade+air-cooled type |
Cascade+air-cooled type |
Cascade+air-cooled type |
|||||||
refrigerant |
R404A |
R23、R404A |
R23、R404A |
R23、R404A |
|||||||
evaporator |
Air-cooled plate fin cooler |
||||||||||
Expansion mechanism |
Electronic expansion valve/capillary tube |
||||||||||
heater |
Nickel chromium alloy electric wire heater |
||||||||||
humidifier |
SUS316 Armored Heater (Surface Evaporative) CTH Model |
||||||||||
|
Size of experimental area W×D×H(mm) |
500×400×500 100L |
600×500×750 225L |
800×800×800 512L |
1000×800×1000 800L |
|||||||
Dimensions W × D × H (mm)*5 |
750×1100×1500 |
850×1300×1700 |
1050×1700×1800 |
1250×1700×2000 |
|||||||
Safety specifications |
Cut off control circuit, prevent excessive temperature rise, overload relay, freezer protection circuit, leakage cut-off machine, external alarm terminal, water shortage alarm |
||||||||||
Permissible environmental conditions |
+5~35℃ |
||||||||||
Power Specifications |
220V AC 1ø 50/60Hz |
380V AC 3ø 50/60Hz(Three phase four wire+protective earth wire) |
|||||||||
*1
Temperature box according to JJF1101-2019 environmental testing equipmentCalibration Specification for Temperature and Humidity Parameters, ambient temperature+23 ℃When the relative humidity is 65 ± 20% R.H and there is no sample.
*Regarding -70 ℃, please consult.
*3. Large humidity range and high-precision control (20~98% R.H) are optional options
*4. Automatic water supply (humidity) can be selected.
*5 does not include protruding parts.