Czech Norton multifunctional coating thickness gauge

NegotiableUpdate on 01/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Czech Norton multifunctional coating thickness gauge is used to measure the thickness of metal surface coatings, electroplated coatings, thick coatings, roughness, steel position, etc. It has multiple sensor options.
Product Details

Czech Norton multifunctional coating thickness gauge

This instrument is an imported instrument. Used for measuring the thickness of metal surface coatings, electroplated coatings, thick coatings, roughness, steel position, etc., with multiple sensor options.

Product Usage:(According to the selection of different probe sensors, their purposes vary

1Electroplating coatings (zinc, chromium, nickel, cadmium, silver, tin, and other coatings) on steel products.

2Electroplating layers (zinc, chromium, nickel, cadmium, silver, tin, and other coatings) on non-ferrous metal products.

3Coatings, paints, enamels, powders, mastics, and other insulation coatings for steel products.

4Anodized oxide coatings, phosphide coatings, and other insulation coatings for black and non-ferrous metals.

5Special insulation coatings and thick metal coatings, electroplated coatings.

6Coating the inner surface of pipelines and cylindrical products.

7Copper foil for printed circuit boards.

8Electroplating coatings on thin plates and insulation products made of colored conductor materials.

9Two layer component coating.

10Concrete protective layer and determination of steel reinforcement position in concrete.

11Measurement of wall thickness of large thin glass and carbon fiber reinforced plastic products with entrances at one end and both ends (measurement during production and delivery).

12Measure the depth of the groove and evaluate the surface roughness after sandblasting or gravel impact.

13Control weather conditions (air humidity, air and metal surface temperature, dew point temperature, and measure temperature change parameters).

Product advantages:

1Automatically calculate the upper and lower limits of the average band.

2The measurement results are displayed in the statistical sample.

3Scan mode with upper and lower limit values.

4Diagonal2.4inchTFTColor display screen with built-in lithium battery.

5Ergonomic shock-absorbing design with rubber protection at the corners.
6
The keyboard comes with function keys that can be adjusted according to the device's working mode; The user interface is user-friendly and intuitive.

7Additional modes and device settings.

8Ergonomically designed small-sized wear-resistant sensor expansion component.

9Sensors that support multiple calibration features (forPH3Series probes, supporting up to6One; ForNF-GProbe, supports up to4One; ForF-GProbe, supports up to2A).

Basic technical characteristics:

Measurement range:0.5 µm120 mm(Multiple probe options available)

Number of sensors:Customers can choose for themselves

calibration method

·Additional single point calibration

·Two-point calibration

·Single point (with automatic multiplication correction)

Computer connection:USB 2.0通道

temperature range

·For devices:-30……+40

·For sensors:-40……+50℃ (For high-temperature sensors, the temperature can reach up to+350℃)

power supply

Built in lithium-ion battery,3.74.2 V, 15001700 mAh

Overall size:60×125×25mm

Electronic unit weight:120g

Continuous working hours:12hours or more

Charging time:4hour

warranty period

main unit of the instrument-3year

sensor-2year

Deliver components

Instrument host and sensors (quantity and model can be selected by customers)

charger

Coating thickness and substrate reference sample (based on the selected sensor)

mini-USBUSB AType computer connection cable

Operation Manual

Shockproof packaging box

Czech Norton multifunctional coating thickness gauge

Magnetic induction and eddy current combined probe

FNF

Used to measure the thickness of coatings, powder layers, plastic layers, glazes, and other non-conductive coatings on conductive ferromagnetic and non-magnetic substrates.

捷克诺顿多功能涂镀层测厚仪

Technical features:

Measurement range:0-1500μm (1.5mm)

Measurement accuracy:±(0.015T + 1)μm

Diameter of measurement area:6mm

Minimum substrate diameter: convex surface/Concave surface Φ4mm/Φ12mm

Size: Φ21×90mm


Magnetic induction probe

For the measurement of coating thickness on ferromagnetic substrates,K6-CofFThe series probe includes a calibration characteristic curve.

F0

Used for measuring electroplating layers (zinc, chromium, cadmium, etc.) and insulation layers (plastic, paint, etc.) on small-sized components (small curvature radius), as well as hard to reach areas on ferromagnetic materials

捷克诺顿多功能涂镀层测厚仪

Technical features:

Measurement range:0-300μm0.3mm

Measurement accuracy: ±(0.02T+1) µm

Diameter of measurement area: Φ3mm

Minimum diameter of substrate: Φ4.5mm(Φ1mm

Size: Φ9×34mm

Note: Pen type probe; Fixed measurement system; The minimum diameter of the measurement area * is not affected by the conductivity of the coating.

Technical features:

Measurement range:0-300μm0.3mm

Measurement accuracy: ±(0.02T+1) µm

Diameter of measurement area: Φ3mm

Minimum diameter of substrate: Φ4.5mm(Φ1mm

Size: Φ9×34mm

Note: Pen type probe; Fixed measurement system; The minimum diameter of the measurement area * is not affected by the conductivity of the coating.



F0/90

Used for measuring electroplating layers (zinc, chromium, cadmium, etc.) and insulation layers (plastic, paint, etc.) on small-sized components (small curvature radius), as well as hard to reach areas on ferromagnetic materials.

捷克诺顿多功能涂镀层测厚仪

Technical features:

Measurement range:0-300μm0.3mm

Measurement accuracy: ±(0.02T+1) µm

Diameter of measurement area: Φ3mm

Minimum diameter of substrate: Φ4.5mm (Φ1mm)

Size: Φ20×127mm

F1

Metal coatings are particularly suitable for measuring electroplating layers (zinc, chromium, cadmium, etc.) and insulation coatings (plastic, paint, etc.) on small-sized components made of ferromagnetic materials.

捷克诺顿多功能涂镀层测厚仪

Technical features:

Measurement range:0-500μm0.5mm

Measurement accuracy:±(0.02T+1) µm

Diameter of measurement area: Φ4mm

Minimum diameter of substrate: Φ4.5mm (Φ1mm)

Size: Φ9×65mm

Note: Wear resistant probes equipped with spring measurement systems are used to control electroplating coatings and are not affected by coating conductivity.


F2

Used for measuring non-conductive coatings (coatings, powder coatings, anodized coatings, etc.) and conductive non-magnetic coatings (zinc, chromium, etc.) on ferromagnetic materials. Measuring range up to2Millimeters.

捷克诺顿多功能涂镀层测厚仪

Technical features:

Measurement range:0-2000μm2mm

Measurement accuracy:±0.02T µm

Diameter of measurement area: Φ6mm

Minimum diameter of substrate: Φ9mm (Φ1.5mm)

Size: Φ19×83mm

Note: Probe equipped with spring measurement system. Use hard metal material as the probe front end to prevent probe wear.


Eddy current measurement probe (specialized probe for measuring nickel plating)

K6-CofPHThe series probe includes a "coating/Matrix characteristic curve.

PH1

Used for measuring electrolytic nickel, zinc, and other electroplated coatings on steel substrates.

捷克诺顿多功能涂镀层测厚仪

Technical features:

Measurement range:0-120μm

Measurement accuracy: ≤±(0.03T + 1) µm

Diameter of measurement area: Φ4.7mm

Minimum diameter of substrate: Φ1mm

Size: Φ12×40mm

Note: The electroplating coating under the controllable insulation layer


PH3

Used for measuring electroplated coatings (zinc, chromium, nickel, copper, cadmium, etc.).

捷克诺顿多功能涂镀层测厚仪


Technical features:PH3-0,2 || PH3-1,8

Measurement range:0-120Mm || 40 μm

Measurement accuracy: ≤±(0.03T + 1) ||≤±(0.03T + 1) µm

Diameter of measurement area: Φ1mm ||Φ1mm

Minimum diameter of substrate: Φ1mm ||Φ75mm

Size: Φ6×50mm ||Φ6×50mm

Note: The electroplating coating under the insulation layer can be controlled.