- Phone
- Address
Tianjin Xun'er Technology Co., Ltd
Special instrument for liquid cooling temperature control solution
1、 Compact electromagnetic flowmeter for liquid cooling)/temperature controlSpecialized electromagnetic flowmeter
Application scenarios:CDUTotal inlet of cooling capacity distribution unitwater/Monitoring of total return water flow, measurement of large-diameter flow in the cooling circulation main pipe and main road of the computer room, statistics and energy consumption analysis of the circulation flow of the submerged liquid cooling system, flow control and overload protection of the centralized liquid supply system.
Product IntroductionThe upgraded product integrates the sensors and converters of traditional electromagnetic flow meters into one, with a compact appearance and flexible installation. It uses an infrared remote control for operation, easy installation and debugging, and is widely used in various industries to measure high conductivityYu2.5uS/cmThe volumetric flow rate of conductive liquids is an inductive instrument used to measure the volumetric flow rate of conductive media.
pickuseARMCortex-M432Bit processorand24bitADCThe data acquisition system has fast computation speed and high accuracy. The instrument has self diagnostic functions such as air traffic control detection, excitation fault alarm, flow alarm, etc. Its unique excitation technology has applied for an invention patent. The sensor adopts input口PEEKMaterial as lining, electrodeandPEEKThe lining adopts a one-time injection molding process, ensuring the consistency and reliability of product production. The overall assembly process has also applied for multiple patents.
2、 Liquid cooled specialized electromagnetic flowmeter (intelligent type))/Temperature control dedicated electromagnetic flowmeter (intelligent type)
Application Scenario:Supply of liquid cooling units, cold plates, and submerged liquid cooling systemswater/Total return water flow, monitoring heat exchange capacity, monitoring cabinet, server, battery cluster, and cold plate branch flow to avoid uneven flow causing local overheating
Product IntroductionThe updated product isThe instrument that uses Faraday's law of electromagnetic induction to measure the volumetric flow rate of conductive liquids is a velocity type instrument, mainly composed of an electromagnetic flow sensor and a converter.
Electromagnetic flowmeter is a high-quality electromagnetic flowmeter based on advanced technology experience of flow meters at home and abroad, optimized and designed. It has high measurement accuracy, good repeatability, no pressure loss, reliable structure, and is not affected by medium temperature, pressure, or viscosity. It supports bidirectional measurement and intelligent self diagnosis. The device has high integration and can be connected to liquid cooling control systems through multiple communication protocols. It is widely used in main and end branches of cold plate and submerged liquid cooling, as well as industrial liquid cooling scenarios such as lasers and semiconductors, providing reliable data support for system energy consumption monitoring and energy efficiency optimization.
3、 Liquid turbine flowmeter for liquid cooling (miniature))/Temperature controlled liquid turbine flowmeter (miniature)
Application scenarios:Server single cold plateenter/outbound traffic,CDUAllocation unit small caliber branch metering,Precision chiller, micro cooling module flow monitoring,Leak detection, flow balancing, and flow interruption protection for liquid cooling systems.
Product IntroductionThis productXun'er Technology is specially designed for liquid cooling temperature control scenarios, suitable for fluid monitoring and measurement in various liquid cooling systems. Real time output of instantaneous and cumulative flow data for liquid cooling circuits.
This instrument is suitable for the strict usage requirements of the liquid cooling industry, with significant performance advantages and measurement accuracyreach0.2~1.0Level, millisecond response speed can accurately capture transient changes in liquid cooling flow rate, with range coveragecover1:10~1:20Capable of adapting to wide flow fluctuations in liquid cooling systemsmoreover;The product has a compact structure and small volume, with extremely low fluid pressure loss and no impact on the circulation efficiency of the liquid cooling circuit. It supports horizontal and vertical multi scene safetypretend(Meet the requirements of the straight pipe sectionCan)Strong compatibility. Widely used in liquid cooling fields such as data center liquid cooling, industrial equipment liquid cooling, new energy thermal management, electronic heat dissipation, energy storage cooling, etc., it accurately adapts to flow measurement and real-time monitoring of various clean and low viscosity liquid cooling media such as deionized water, ethylene glycol coolant, methanol based coolant, etc.
4、 Special liquid turbine flow rate for liquid coolingplan/Temperature control specific liquid turbine flow rateplan/Special liquid turbine flowmeter for liquid cooling and temperature control
Application Scenario:coldboard/Immersion cooling circuit total flow, branch flow monitoring and measurement of supply and return water flow, monitoring of heat exchange efficiency and monitoring of each machinecabinet/Equipment cooling flow rate ensures even flow distribution
Product IntroductionThis productThe body material is made of all stainless steel and can be used to measure non corrosive pure liquids, with good measurement effect for pure water. This product, due to its principle characteristics, has high precision, good repeatability, and extremely high sensitivity to changes in fluid flow rate. It is suitable for use as a positive electrode material in power batteries and in quantitative control processes in the chemical industry.
Convenient access to liquid cooling control system, widely used in cold plate and submerged liquid cooling end branchesTheCDUDistribution units, as well as industrial liquid cooling circuits such as lasers and semiconductors, provide reliable data support for precise flow control and energy consumption accounting of the system.
5、 Liquid cooled temperature control dedicated temperature transmitter
Application Scenario:Outdoor and indoor environmentrealm:Primary side cooling tower inlet and outlet air dry and wet bulb, primary side cooling water circulation cabinet interior
Secondary side refrigerant circulation.
Product IntroductionThe armored temperature transmitter produced by our company has a simple structure, compact size, economic durability, and is not easily damaged. It can output multiple standard flow signals for users to choose from. Generally used for installation on the supply and return water pipelines at the front and rear ends of plate heat exchangers. Can be installed and replaced online.
Integrated temperature transmitter is a field installed temperature transmission unit in temperature instruments. Integrated temperature transmitter integrates sensors and transmitters to directly measure various industrial processes,-200~1600°CThe temperature of liquid, vapor, and gas media within the range is converted into a temperature proportional to the electrical signals of thermocouples and thermal resistorsof4~20mAUnified output signal, sent to display, record and adjust instruments or computers. As a new generation temperature transmitter, integrated thermoelectricby chance(block)Temperature transmitters can be widely used
Used in various departments such as metallurgy, petroleum, chemical, power, light industry, textile, food, national defense, and scientific research. The transmitter components of the integrated temperature transmitter are miniaturized and can be installed in the wiring of thermocouples and thermistors to become an integrated temperature transmitter. As an integrated temperature transmitter for direct transmission in industrial sitesout4~20mAThis not only eliminates the need for expensive compensation wires, but also improves the anti-interference ability during long-distance signal transmission.
The transmitter components have high accuracy, low power consumption, wide temperature range for use, and stable and reliable operation. And due to the use of silicone rubber for sealing
Sealed structure, the transmitter is shock resistant and moisture resistant, suitable for use in harsh on-site environments.
5、 Special pressure transmitter for liquid cooling temperature control
Application Scenario:Various industrial self-control environmental measurements are used for high-precision measurement of liquid level, density, and pressure of liquids, gases, or vapors. Secondary side refrigerant circulation
Product Introduction:A pressure transmitter is a type of pressure transmitter that has a flexible appearance, stable measurement, and high accuracy. There are three pressure measurement methods: gauge pressure, absolute pressure, and negative pressure. The diffusion silicon sensor and its manufacturing process are used to ensure high-quality performance and long-term stability. By using three buttons for free on-site configuration, zero and full range can be adjusted on site. And can be installed with a high contrast back straplightLCDThe monitor has multiple process connectors.
Product Features:
Easy to install, can be installed directly, or can be installed using a bracketpretend;
High precision, high stability, high reliability, anti frequency conversion interference capabilitystrong;
Gauge pressure, absolute pressure, and negative pressure can all be measuredquantity;
Zero point transferable, range adjustablesection;
Supporting networking shoulduse;
5、 Liquid cooled temperature control dedicated online analyzerwatch\\Liquid cooling dedicatedPH/ORPtransmitter
Application scenarios:Solutions for thermal power, chemical fertilizers, metallurgy, environmental protection, pharmaceuticals, biochemistry, food and tap water, etcmiddlePHValue orone whoORPContinuous monitoring of secondary side refrigerant circulation for values and temperatures.
productIntroductionThis productIt is one of the intelligent online chemical analysis instruments, widely used in solutions such as thermal power, chemical fertilizers, metallurgy, environmental protection, pharmaceuticals, biochemistry, food, and tap watermiddlePHValue orone whoORPContinuous monitoring of values and temperature.
Continuous monitoring data is transmitted through a transmitter and connected to a recorder for remote monitoring and recording, and can also be connectedpick upRS485Interface communicationpassModbusrtUThe protocol can be easily connected to a computer for monitoring and recording.
6、 Liquid cooled temperature control dedicated online analyzerwatch\\Liquid cooled turbidity meter
Application scenarios:Liquid cooling unit and heat exchange station data center liquid cooling system industrial liquidcold/Secondary side refrigerant circulation for equipment cooling
Product IntroductionThis productAdopting the current approachof90°It is manufactured based on the principle of scattered light measurement, and the sensor has a unique design and stable voltage defoaming technology, with extremely high sensitivity. It is widely used for turbidity measurement of pre -, post -, and effluent water in water treatment plants, as well as for monitoring turbidity in municipal pipeline networks and small-scale turbidity measurement at sewage plant outlets.
6、 Liquid cooled temperature control dedicated online analyzerwatch\\Liquid cooling dedicatedconductivity
Application scenarios:Data center coolingboard/Online monitoring of the main circuit of immersion liquid cooling system,Monitoring of cooling water conductivity in energy storage liquid cooling system. Online monitoring of supply pipes, return pipes, and bypass pipes in liquid cooling system.
Product IntroductionThis productThe use of quadrupole conductivity and temperature compensation makes the measurement more accurateindeed;Widely used in water treatment, electricity, medicine, food, chemical industry, metallurgy, electroplating, and tap water
Online monitoring of conductivity in the process. It can be used for real-time monitoring of the conductivity value of the coolant medium, accurately reflecting the purity, ion concentration, and pollution level of the coolant. Real time output signal monitoring system can detect anomalies such as impurity mixing, pipeline corrosion, internal leakage, and ion exchange unit failure. Through high and low limit alarm and system linkage, the risk of electrochemical corrosion, decreased heat transfer efficiency, and equipment damage is effectively avoided. It is widely used in the liquid cooling industry in data centers, energy storage, power batteries, and industrial liquid cooling systems, providing critical water quality monitoring and guarantee for the safe and stable operation of cooling systems.