Brief introduction: The alternating cold and heat aging chamber is a reliability testing equipment for various electronic, electrical, electrical, plastic and other raw materials and devices to conduct cold resistance, heat resistance, moisture resistance, dry resistance tests and quality control engineering; Especially suitable for fiber optics LCD、 Crystals, inductors PCB、 High temperature resistance, low temperature resistance, and moisture resistance cycling tests for products such as batteries, computers, and mobile phones.

Product Details

Details introduction:

Cold and hot alternating aging chamberapplication:
The high and low temperature alternating test equipment complies with the temperature and humidity testing standards of the air circulation system, which can simulate testing conditions in different environments such as high temperature, low temperature, low temperature, and high temperature. It is equipped with a high-precision programming system that is easy to operate and learn, providing relatively stable testing performance conditions. This product is used for reliability testing of high and low temperatures. The adaptability test of electronic and electrical products, automobiles and motorcycles, aerospace, rubber, plastics, metals, marine weapons, universities, research institutions, and other product components during storage, transportation, and use in high and low temperature and humid environments is conducted to determine the temperature resistance and adaptability of the above products to high and low temperature and humid environments, especially the changes in electrical and mechanical properties of the products, which can also be used to check the ability of the samples to withstand certain corrosion. Conduct relevant tests on its various performance indicators.


Cold and hot alternating aging chambercontrol systemPRODUCT FUNCTION:
The temperature control adopts a fully imported touch button instrument, with simple operation and setting.
After inputting the data and experimental conditions, the controller has a locking function to prevent human touch from changing the temperature value.
Equipped with P.I.D automatic calculation function, it can immediately correct temperature change conditions, making temperature control more precise and stable.
The main component of the electrical control adopts the Korean TEMI300 instrument to better control the temperature


Cold and hot alternating aging chamberrefrigeration systemProduct Features:

The refrigeration unit adopts the original French "Taikang" fully enclosed compressor.
The American "Aigo" drying filter, the Italian "Casito" solenoid valve, and the refrigeration system adopt a unit or binary low-temperature circuit system design. The new generation of exterior design has undergone significant improvements in box structure, refrigeration system, and control technology, resulting in more stable technical indicators, more reliable operation, and easier maintenance. It is equipped with high-quality universal rollers for easy movement within the laboratory.
► Large touch screen operation, with a simpler and more elegant appearance, and easier operation
► Vacuum double-layer glass: large window design, Philips high brightness lighting, heated without fog
► Provide more interface options for programming and document processing, with large recording volume, output, and computer connection printing (optional)
High reliability: The main accessories are selected from professional manufacturers to ensure improved overall reliability


Cold and hot alternating aging chamberProduct Album


Cold and hot alternating aging chamberParameter specifications:

The high and low temperature alternating test chamber prohibits the testing and storage of flammable, explosive, and volatile substance samples, corrosive substance samples, biological samples, and strong electromagnetic emission source samples.

Equipment model

DEJG-500 type

Working Size

700×800×900mm

External dimensions

1250×1350×1760mm

total power

About 5.0 KW

Main performance parameters

temperature range

0℃ ~+150℃

Temperature deviation

≤±2.0℃

temperature fluctuation

≤±0.5℃

Heating and cooling rate

heating up time

2-3 ℃/min (when the equipment is unloaded)

Cooling time

0.7~1 ℃/min (when the equipment is unloaded)

volume

rise

Xiamen Deyi CompanyHigh and low temperature alternating test chamberThere are also capacities of 80L, 100L, 150L, 250L, 408L, 500L, 600L, 800L, and 1000L available for purchase!

Performance characteristics

Programmable temperature controller

monitor

5.7 "320 × 240 dot matrix color LCD display. (TEMI880, South Korea)

Operation mode

Fixed value or program

Setting method

Chinese menu, touch screen input

Program capacity

Can store 120 sets and 1200 segments of test procedures

program length

Each program has an additional 99 segments

Number of cycles

Each program segment can loop 999 times

Setting Range

Temperature: 0 ℃~+150 ℃

Time: 0-999 hours and 59 minutes

resolution

Temperature: 0.1 ℃

Time: 0.1min

input

PT100 platinum resistor

communication

Equipped with an RS232/485 interface

Auxiliary functions

Alarm display function (indicating the cause of the fault), power outage protection function, upper and lower limit temperature and humidity alarm function, timing function (automatic start and stop), self diagnostic function.

Measurement data collection

PT100 platinum resistor

Cabinet material

Inner box material

Stainless steel plate

Outer box material

Stainless steel plate

thermal insulating material

Rigid polyurethane foam+glass fiber

door

Single door, equipped with observation window, lighting, left hinge and right handle

refrigeration system

refrigeration compressor

Original French imported "Taikang fully enclosed piston compressor"

Cooling method

Compression adopts a cascade refrigeration system for cooling

Cooling method

forced air cooling

evaporative condenser

Brazed plate heat exchanger

condenser

air-cooled condenser

Control mode of refrigeration machine

The PLC (Programmable Logic Controller) of the control system automatically selects and adjusts the operating conditions of the refrigeration machine according to the test conditions
Condensation pressure regulating valve
Evaporator Pressure Regulator
Compressor return air cooling circuit
Energy regulation circuit

refrigerant

Using green and environmentally friendly refrigerants R404A and R23 as the refrigeration medium for this refrigeration system

Main refrigeration components

Main refrigeration accessories: solenoid valve (SANHUA, Japan), filter (Danfoss, Denmark), pressure controller (Danfoss, Denmark), oil separator (Aiko, USA), plate heat exchanger (Shuripe, Sweden), etc. are all imported brand products.

**Protective device
Main advantage

Residual Current Device (RCD)

Compressor overpressure protector

Over temperature protector inside the box

Compressor overheat protector

Fan overheat protector

Compressor overcurrent protector

phase sequence relay

Air conditioning channel A

Centrifugal fans: 2 units

Test box standardaccessory

Observation window: 1 transparent electric heating film insulated tempered glass (located on the door)
The visual range is approximately 280mm × 350mm, including the range of lighting obstruction.

Lead hole: 1 hole with a diameter of 50mm (located on the left side of the box)

Indoor lighting fixture on the door: 1 36W/220V

Mobile wheels: 4

Test hole: 1 50mm hole on the left side of the body, with 1 stainless steel hole cover and 1 silicone plug.

Power cord 5m

Sample rack: 2 layers of stainless steel sample rack, load-bearing capacity (evenly distributed): 25kg/layer
(The cumulative total load capacity of the samples in the box shall not exceed 100kg)

working conditions

power supply

○ Voltage allowable fluctuation range: AC220V ± 10%
○ Allowable frequency fluctuation range: 50Hz ± 0.5 Hz
The grounding resistance of the protective grounding wire is less than 4 Ω; TN-S power supply or TT power supply

Usage environment

Temperature: 5 ℃~35 ℃, relative humidity: ≤ 85% RH

site

○ The ground is flat, well ventilated, and free of flammable, explosive, corrosive gases and dust
There is no strong electromagnetic radiation source nearby
○ Leave appropriate maintenance space around the equipment

Meet standards

GB/T 2423.1-2008 Test A: Low temperature test method

GB/T 2423.2-2008 Test B: High temperature test method

GJB 150.3A-2009 High Temperature Test

GJB 150.4A-2009 Low Temperature Test

Precautions for Cold and Hot Alternating Aging Box

1. The inspection and adjustment of the wet bulb water level in the high and low temperature alternating humidity test chamber should not be too high in the water tank, causing water to overflow from the tank or too low, resulting in abnormal water absorption of the wet bulb test cloth and affecting the accuracy of the wet bulb. The water level should be kept at about six tenths full. The adjustment of the water level in the water tank can adjust the height of the water tank.

2. The replacement of the wet bulb test cloth in the high and low temperature alternating humidity test chamber is necessary when the surface of the test cloth is not clean or hardened, or before continuing to perform temperature and humidity bulb control after completing temperature control. The test cloth should be replaced about every three months. When replacing, the temperature sensor (Sen sor) should be wiped with a clean cloth. When replacing the new test cloth, it should be cleaned first.
3. The condenser of the high and low temperature alternating humidity test chamber should be regularly maintained every month to remove the dust attached to the condenser cooling mesh using a vacuum cleaner or high-pressure air spraying.
4. During the operation of the high and low temperature cyclic testing machine, the setting of the over temperature protection in the high and low temperature alternating humidity test chamber should be increased by 20 ℃~30 ℃. When the temperature inside the test chamber rises to the set point for over temperature protection, the power supply to the heater stops, and the 'OVERHEAT' over temperature warning light lights up but the fan still runs. If it runs for a long time without supervision, please make sure to check the over temperature protector before operation to ensure that it is properly set (the wet bulb over temperature protector is set to 120 ℃).



Xiamen Deyi Company's main products:High and low temperature alternating humidity test chamber, high and low temperature humidity test chamber, high and low temperature alternating humidity test chamber, high and low temperature test chamber, high and low temperature impact test chamber, constant temperature and humidity test chamber, low temperature constant temperature and humidity chamber, low temperature and low humidity chamber, low temperature constant temperature chamber, ventilated aging chamber, ventilated thermal aging chamber, xenon lamp aging test chamber, ultraviolet weather resistance test chamber, ozone aging test chamber, rain test chamber, swinging tube rain device, strong flushing test device, anti immersion test device, sand and dust test chamber, salt spray test chamber, yellowing resistance test chamber, electromagnetic vibration test bench, constant temperature drying chamber, vacuum drying chamber, electric blast drying chamber, precision drying chamber, glassware drying chamber and other environmental testing equipment.