CIT-JHCoke oven infrared thermometerIt is a high-tech product developed based on the strong theoretical and technological accumulation of the Automation Research Institute, years of rich engineering practice experience in the coking field, and tailored to the characteristics of Chinese coking enterprises. It has the characteristics of good stability, easy operation, complete functions, and high cost-effectiveness. Successfully put into use in over a hundred coking enterprises across the country and achieved good results.
Coke oven infrared thermometerTechnical parameters:
| Project | Content |
| Measuring range | 700℃~ 1600 ℃ |
| operating wavelength | 0.96 µm |
| temperature measurement accuracy | ± 1% TH (TH: upper limit of temperature measurement) |
| repetitiveness | ±2‰TH |
| Distance coefficient | 70:1 |
| measure distance | 1.5m~∞ |
| sighting system | Visual optical aiming with true measurement area size indication |
| response time | 50ms |
| Emissivity adjustment | 0.10~1.30, adjust step size by 0.01 |
| output interface | Wireless reception of infrared data |
| Button | 6 tactile touch sound buttons (single sound effective, dual sound ineffective) |
| special function | 1000 sets of temperature data with date/time parameters: ---Storage ---Storage data query ---Store data playback to PC ---Clear stored data Automatically shut down at the time set by the user; On site temperature calibration; |
| Power requirements [1] | 2 AA batteries, size 5 |
| Power consumption | Standby<3mA under backlight off condition Temperature measurement<12mA under backlight off condition Temperature measurement under backlight conditions<15mA |
| battery life | Under the condition of turning off the backlight, it can be used continuously for 2 hours a day for at least 4 months; Under the condition of turning on the backlight, it can be used continuously for 2 hours a day, and can be used continuously for at least 2 months; |
| Weight | 1.2kg (including battery) |
| Installation | 1/4 inch screw hole |
| Environmental Requirements | Environmental temperature: 0-70 ℃; Humidity: 0-85% |