Welcome Customer !

Membership

Help

Hangzhou Da Cai Optoelectronics Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Hangzhou Da Cai Optoelectronics Technology Co., Ltd

  • E-mail

    1254280671@qq.com

  • Phone

    18958075880

  • Address

    3rd Floor, 1820 Moganshan Road, Hangzhou, Zhejiang, China

Contact Now

Coarse fiber analyzer SLQ-6

NegotiableUpdate on 06/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Coarse fiber analyzer SLQ-6

Product Details

Coarse fiber analyzer SLQ-6

SLQ-6 Coarse Fiber AnalyzerIntroduction:

The SLQ-6 coarse fiber analyzer is based on the principle of acid-base washing, integrating acid and alkali treatment and rinsing. It uses a fully enclosed electric heating, liquid addition, digestion, filtration, and rinsing method to determine the coarse fiber content. The sample does not need to be transferred during operation, and can decompose the coarse fibers in the material. At the same time, it can be adjusted one by one according to the required temperature, thus achieving accurate and fast results.

The SLQ-6 coarse fiber analyzer is suitable for determining the content of coarse fiber, lignin, cellulose, and hemicellulose in grains, feed, food, and other agricultural and sideline products.

The SLQ-6 coarse fiber analyzer has no clogging during filtration and can measure the coarse fiber content of puffed samples that cannot be measured by other instruments.


SLQ-6 Coarse Fiber AnalyzerTechnical parameters:

1. Test range: 0-100%;

2. Sample quantity: 1-6 samples can be tested simultaneously at a time;

3. Sample weighing: 0.5-3g;

4. Test accuracy: repeatability ≤ 0.4%;

5. Test time: ≤ 90 minutes;

6. ★ Heating method: Half circle silicon carbide heating, single temperature adjustment;

7. ★ Sealing method: Adopt upper and lower tetrafluoroethylene isolation.

8. Temperature control range: room temperature~400 ℃

9. Power supply: 220 (V) ± 10%, 50-60HZ;

10. Rated power: 2000W;

11. Dimensions: 570 × 470 × 750 (mm);

12. Weight: 30kg;

Product Remarks

Boil the sample with a fixed amount of acid and alkali under specific conditions, then remove the ether solution with ether, ethanol, and acetone. After high-temperature calcination and deduction of mineral content, the remaining amount is called coarse fiber. It is not an exact chemical entity, but a rough composition measured under recognized mandatory conditions, mainly consisting of fiber, with a small amount of hemicellulose and lignin.

Attention (Before weighing the sample, lay about 1g of diatomaceous earth first, then operate normally. After the last step is completed, add 20ml of acetone to each crucible and filter three times before cleaning with distilled water once)