Chengdu Jingxin JL-3000 spray laser particle size distribution instrument
JL-3000 spray laser particle size analyzer(Split type)Using the full range Mie scattering theory and proprietary technology of Jingxin Company, the particle size distribution of the measured particles is calculated. The stainless steel chassis shell is fully sealed, dustproof and waterproof, and has good electromagnetic shielding and anti-interference performance.
The interval position between the main engine and auxiliary engine can be freely adjusted according to the size of the measured sample, and the distance can reach up to 10 meters. The built-in camera automatic centering system facilitates the calibration of light sources on the testing site. It can be automatically and continuously tested under computer control to quickly analyze the particle size distribution data of water mist, oil mist, smoke, etc. The precise mechanical structure of * makes the testing speed fast, with good repeatability and stability. Through the particle size distribution data of the droplet measurement, optimize the nozzle design, spray conditions, evaluate the spray effect, and achieve the purpose of developing and controlling product quality.

application field
It is widely used in the research of combustion efficiency products such as pesticide spray, pharmaceutical atomization, fuel spray, fire water spray, various atomizing agent production, aeroengine, as well as scientific research institutions and other fields.
Spray laser particle size analyzer (split type)parameter indicators
project |
indicator |
project |
indicator |
Measuring principle |
Full range Mie scattering theory |
measurement range |
0.1µm~3000µm |
Quality requirements |
According to the standard Q/70920531-0.1-2020 |
detector |
128level |
repeatability error |
≤1%(National standard substance D50 deviation) |
Accuracy error |
≤1%(National standard substance D50 deviation) |
optical path system |
Fourier lens, lens diameter 80mm |
Signal light source |
Imported semiconductor laser |
Installation method |
Flexible placement according to sample sizeBetween the main and auxiliary machines of the instrument. |
Test time |
Can be done once(1Less than 3 seconds),also canMultiple consecutive high-speed automatic tests (50 times/second). |
operating system |
WinXP/Win7/ /Win10 |
Distance between main and auxiliary equipment |
1~10Rice (adjustable as needed) |
Host volume |
Length 900, width 370, height 270 (mm) |
Auxiliary machine volume |
Length 330, width 250, height 370 (mm) |
working power supply |
AC220V±22V; 50Hz ±0.5Hz; |
Environmental Requirements |
Temperature: 5 ℃~35 ℃; Humidity:<85%; |
JL-3000 Chengdu Jingxin JL-3000 spray laser particle size analyzerInstrument advantages
1. Split structure: Installed between the main and auxiliary machines according to the measured components (provided by the user), the distance between the main and auxiliary machines is not limited, making it convenient to test products of different sizes. Under computer control, the device automatically opens and disconnects the measured product to complete the test automatically.
2. Adopting Fourier optics system, large diameter parallel light source, large test cross-section, and strong data representativeness.
3. Large aperture lens with wide signal acquisition angle can fully collect the scattered signal of spray to ensure that the nozzle can be used as far as possible, usually within the range of 100-3000mm.
4.128 level multi-element detector. The particle size is divided into multiple levels with small differences, and the scattered signal detection resolution is high. The background light of the detector is independently compensated at each level to achieve gain, high-speed signal amplification, and sensitive and fast dynamic response. There is a complete spot image detection system behind the detector to obtain the real spot. Comprehensive monitoring of spot uniformity and shape.
5. Imported semiconductor laser, light source: wavelength 650nm, 30mw, lifespan>70000h.
6. High rigidity optical structure, stable optical path, and no need for any adjustments during use. Ensure that the instrument is in long-term stability, with good testing accuracy and repeatability.
7. Because the spray particle size and spray diameter are very different, the laser power can be adjusted in a full range to ensure the resolution and accuracy of the instrument.
8. Adopting RS232 and USB data transmission methods, the transmission distance can reach up to 100 meters.
9. The test data includes cumulative distribution, frequency distribution, cumulative 10%, 50%, 90%, 97%, average particle size, and specific surface area, which comprehensively characterize the particle size characteristics of the sample. Every second of testing, it can be automatically tested continuously for single or multiple times.
10. The software interface can choose between Chinese or English, and the output results can be printed directly or converted to PDF and saved in various formats.
11. In order to meet the needs of different users, it is equipped with program trigger, TTL level and switch trigger high-speed test, and 50 complete test data per second are automatically recorded and saved as the basis for dynamic spray and other research.
12. The analysis software is compatible with Windows XP/Win7/Win10 systems.