Catalyst - Fully Automatic Chemical Adsorption Instrument
Standard Function
◆ Temperature programmed desorption (TPD)Study on desorption kinetics:Fully automatic program response:
◆ Temperature programmed reduction (TPR)◆ Desorption activation energy Ed◆ Fully automatic cycle life evaluation
Programmed Temperature Oxidation (TPO)The desorption coefficient refers to the pre factor Ad◆ Programmable multi-step response
Programmed Temperature Surface Reaction (TPSR)◆ Degrees of detachment n◆ Multi temperature point fully automatic execution
◆ Temperature programmed vulcanization (TPS)◆ Multi temperature point fully automatic
◆ Pulse titration
Technical Parameters
◆ Number of heating furnaces: 2 program-controlled high-temperature furnaces, with room temperature~1200 ℃, serving as backup for each other;
Heating furnace cooling method: dual electric furnaces automatically switch to alternate operation+automatic internal air cooling;
◆ Program heating rate: 1 ℃/min-100 ℃/min;
Analysis of gas inlet: 12 channels;
Mass Flow Controller (MFC): 3 channels, supporting 3 channels of mixed gas chemical adsorption;
◆ Types of adsorbates: various non corrosive gases, corrosive gases, steam, etc;
Vacuum pump: standard configuration, eliminating the impact of dead volume and residual gas in the pipeline on testing;
◆ Steam generator: standard configuration, capable of achieving steam chemical adsorption;
◆ Cold trap: equipped with a standard cold trap to remove the influence of low boiling point components such as water vapor on concentration detection;
Pulse titration: equipped with quantitative tubes of 0.5ml (standard), 1ml, and 5ml;
Test pressure: Standard atmospheric pressure, optional 1Mpa/3Mpa/10Mpa;
Dual combustible gas alarm: Real time monitoring of different areas to prevent combustible gas leakage;
◆ Sample tube: Quartz U-shaped sample tube (with built-in temperature reference tube to improve temperature measurement accuracy);
◆ Constant temperature system: dual constant temperature (gas path system 40-80 ℃, TCD system 60-110 ℃);
◆ External standard injection: equipped with 1ml standard injector, other specifications are optional;
◆ TCD detector dual detection mode: switchable between "high sensitivity" and "wide range" modes,
Meet the testing requirements for weak and strong signals;
◆ Detection system: Standard TCD, optional MS, infrared;
Catalyst - Fully Automatic Chemical Adsorption Instrument
Technical Advantages
◆ Fully automatic testing: The dual heating furnaces switch automatically, and after pre-processing is completed, there is no need to wait for cooling. The testing process can be directly switched to another heating furnace without manual intervention;
Vacuum method gas path flushing: The instrument is equipped with a built-in vacuum pump. Compared with conventional gas path flushing, the vacuum method is more efficient in removing residual gases in the dead volume, reducing baseline drift, and improving testing accuracy;
◆ Temperature reference tube: The temperature sensor is placed in the temperature reference tube of the sample tube (in the same environment as the sample) to ensure high accuracy in temperature control and measurement;
◆ Automatic air cooling system: The air cooling position is equipped with air cooling pipes and temperature detectors, which automatically recognize the temperature of the heating furnace at the air cooling position and automatically turn on air cooling cooling to prepare for the next test;
◆ Support multi-step continuous automatic testing: Fully automatic execution according to the edited multi-step testing plan, used to evaluate the catalytic performance and chemical adsorption performance of materials under complex reaction conditions;
◆ Support automatic cycle testing: pre-processing+automatic cycle testing is used to evaluate the lifespan and chemical adsorption stability of materials;
◆ Ultra low temperature constant temperature&ultra-low temperature programmed heating: Ultra low temperature testing can be achieved without the need for optional ultra-low temperature configuration;
◆ Default high configuration: The default configuration includes a steam generator and a pulsating titration system;
◆ Supports 3 types of analytical gas mixing: 3 channels of analytical gas MFC, supports testing of 3 types of analytical gas mixing;
High reliability: With an international supplier system, all core components are imported