E-mail
13810457507@139.com
-
Phone
13810457507
-
Address
A302 Huiyuan Building, No. 5 Zaojunmiao Road, Haidian District, Beijing
Beijing Jingkeshuo Technology Co., Ltd
13810457507@139.com
13810457507
A302 Huiyuan Building, No. 5 Zaojunmiao Road, Haidian District, Beijing
Capsaicin detectorProduct Overview
Based on competitive enzyme-linked immunosorbent assay, capsaicin and capsaicin enzyme markers are added to the test wells. The capsaicin in the sample competes with the capsaicin enzyme markers to bind to capsaicin antibodies attached to the micropores.
”Accurate results and high cross reactivity rate
”Fast detection speed, results can be obtained in one hour, and the detection cost is relatively low
It can analyze individual samples or analyze samples in batches
Can perform semi quantitative and quantitative analysis
The low detection limit of the reagent kit is 1000ppb (spicy dish) and 100000ppb (chili oil)
H
▼Capsaicin detectorFeatures
※ 7.1 high-resolution color touch screen, easy to operate, no need for additional computer ※ Endpoint method, dynamics, universal mode, single/dual wavelength measurement
※ Fast detection speed, rich software configuration, can be used alone or connected to a computer. ※ When the instrument is started, the system will automatically calibrate the position of the carrier board, light source, and filter. ※ It has a clock function, visual board storage, and detection call command function
The data management function has a large storage space and can export stored data at any time
Technical Specifications
※ Capsaicin test kit and portable detection kit are both optional
1. Light source: halogen lamp, automatic control, with a lifespan of up to 4000h
2. Optical path system: 12 detection channels, 1 reference channel
3. Detector: Imported silicon photodiode
4. Wavelength range: 400-800nm
5. Filter: Standard configuration includes 405, 450, 492, and 630nm, while other wavelengths are optional
6. Reading range: 0-4.000Abs (450nm)
7. Linear range: 0-3.000Abs (450nm)
8. Filter bandwidth: 8nm
9. Resolution: 0.001Abs
10. Accuracy (405nm): ± 1% (0-3Abs), ± 2% (3-4Abs)
11. Accuracy (405nm): CV ≤ 0.2% (0-3Abs), CV ≤ 1% (3-4Abs), standard measurement mode
12. Indication error: ≤± 0.01Abs
13. Stability: ≤± 0.003Abs
14. Repeatability: ≤ 0.3%
15. Vibration board function: Three adjustable speeds: high speed, medium speed, and low speed, with adjustable time from 0-999 seconds
16. Display operation: 7.1Inch touch screen input and display of whole board information
17. Reading speed: single wavelength3second/96 holes, dual wavelength 6 seconds/96 holes
18Workstation: Computer based enzyme-linked immunosorbent assay (ELISA) analysis software, equipped with comprehensive functions such as project detection, data processing, curve fitting, and data management.
19Endpoint method, two-point method, dynamics, single/dual wavelength testing modes, etc
20Data output: COM+USB (communication, printer, USB drive)
21Printer: Optional thermal printer
23Power supply: wide voltage design AC100-240V 50Hz.
24Net weight: approximately 11.5Kg
25.ruler Inch:420mm(L)*320mm(W)*160mm(H)