SHP(E)series
Product Usage
Calibration Specification for Biochemical Thermostatic ChamberUsed for environmental protection, health and epidemic prevention, drug testing, agricultural and sideline, aquatic research, universities, and production departments, it is used for water analysis andBODMeasurement, specialized equipment for various constant temperature tests, environmental tests, cultivation, preservation, plant cultivation, and breeding experiments of bacteria, molds, and microorganisms.
Product Features:
Calibration Specification for Biochemical Thermostatic ChamberAdopting a compressor unit protected by high and low pressure, intelligent refrigeration frost free operation technology, and a self detecting compressor start and stop control program, it has low noise, long service life, and small temperature fluctuations.
The studio is equipped with lighting fixtures and large angle insulated vacuum tempered glass for easy observation;
Equipped with sensor fault alarm, over temperature alarm, self diagnostic dynamic control, temperature display correction, parameter memory, and long duration9999Minute timer function.
4.Independent temperature limit control alarm system, automatically interrupts operation when the temperature exceeds the limit, with dual protection.
Usage:
1Connect the power supply that meets the requirements of this instrument and ensure that the grounding terminal of the power socket used is reliably grounded.
2Turn on the power switch, the power indicator light will turn on, and the temperature controller will start displaying the temperature inside the working room.
3Set the temperature according to the required temperature of the culture, and automatically stabilize it when the set temperature is reached.
Precautions and daily maintenance:
1Firstly, the grounding of the equipment should be done well, and a wire twice as thick as the power cord should be selected for grounding.
2Samples should not be placed at the bottom of the studio, and samples on shelves should not be placed too tightly to avoid shadows
The airflow inside the sound box circulates.
3 First timeWhen the equipment is put on hold for a long time or restored to use, it should be started with no load6one8Hour, clear cause
Normal use should be carried out after possible malfunctions during transportation or storage to avoid unnecessary losses.
4The biochemical chamber must be placed in a dark, ventilated, and dry place.
5Do not use acid, alkali, or other corrosive substances to scrub the inner and outer surfaces. Neutral detergent can be used for regular cleaning, and a thousand cloth can be used for wiping.
6When replacing a fuse, replace it with the same fuse according to the marked fuse current and size requirements
Breaker.
7When the biochemical chamber is not in use, the power should be cut off and the chamber should be kept clean and dry.
Accessory prices:
LCD controller 、、、、、880.00yuan
Digital display controller 、、、、、600.00yuan
RS-485Interface 、、、、、 320.00yuan
Partition net 、、、、、、100-260.00yuan
Embedded printer 、、、、、1700.00yuan
Product Parameters:
model |
SHP-80(E) |
SHP-150(E) |
SHP-250(E) |
SHP-450(E) |
|
|
working environment |
ambient temperature5~30℃ |
||||
Relative humidity ≤80% | |||||
Altitude ≤2000m | |||||
power supplyAC220V±10% 50Hz±1Hz | |||||
scope of control |
5℃~65℃ |
||||
|
temperature |
accuracy |
±0.3℃at 37℃ |
|||
volatility |
±0.3℃ |
||||
uniformity |
±0.3℃at 37℃ |
±0.3℃at 37℃ |
±0.5℃at 37℃ |
±1℃at 37℃ |
|
controller |
LCD display, touch sensitive, blurryPIDTemperature Control of Microprocessors in Control Technology |
||||
sensor |
High precision platinum resistance sensor |
||||
time |
0~9999minute |
||||
power consumption |
430W |
500W |
750W |
1200W |
|
material |
internal |
premium304Mirror-finished stainless steel |
|||
外部 |
08Fcold-rolled steel sheet |
||||
|
size (MM) |
internal |
400*400*500 |
500*400*750 |
550*500*900 |
700*650*950 |
外部 |
500*620*1140 |
600*610*1500 |
650*710*1650 |
880*830*1700 |
|
Note:EFor the upgraded model, in addition to the above functions, it also has an intelligent temperature control LCD displayRS-485Interface, embedded printer.