CS-3000HDR/CS-3000 spectrophotometer

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Konica Minolta CS-3000HDR/CS-3000 spectrophotometer is a high-precision spectrophotometer used for display screen testing. It can simultaneously measure brightness and chromaticity and is widely used in the research and production line quality control of various display screens (LCD, OLED, Mini/Micro LED), as well as the measurement of small light sources such as automotive instrument panels.

Product Details

Konica MinoltaCS-3000HDR/CS-3000 spectrophotometerProduct Introduction

There are three models in the product lineup, exceptIn addition to the flagship model CS-3000 HDR and standard model CS-3000, the CS-3000 series also includes the cost-effective model CS-2000Plus, which is equipped with a high-speed computing CPU and new algorithm/INTERLIGHT DARK function on the traditional model CS-2000.

CS-3000HDR/CS-3000分光辐射亮度计

characteristic

CS-3000HDR

CS-3000

CS-2000Plus

andCS-2000 data compatibility

INTELLIGENT DARK functionality

Luminous frequency detection and setting function


shortenMeasure time in NORMAL mode


Electric switching measurement angle


application

With high sensitivity and low noise measurement design, high-speed and high-precision measurement can be achieved when measuring TV and smartphone displays, or when measuring micro displays with small measurement angles. Through the focus locking function and a new design, the potential impact of instrument installation direction on measurement values is weakened, making the device also suitable for vertical installation. By installing an illuminance adapter (optional accessory), it can also be used as a reference device for projector measurement.


Konica Minolta CS-3000HDR/CS-3000/CS-2000Plus spectrophotometerProduct Features:

high precision

Inheriting excellent optical design and signal processing technology, it has achieved high precision required for measuring standard values of various light sources such as display screens.CS-3000 strictly follows the recommended requirements of CIE 122-1996 for chromaticity measurement, using a half wave width measurement of less than 5nm throughout the entire visible light wavelength range to ensure accurate measurement of signal-to-noise ratio suppression at low brightness. In addition to the CIE1931 xy chromaticity, it also ensures the accuracy of u'v 'in the CIE1976 UCS chromaticity diagram.
Chromaticity measurement accuracy (low brightness)0.05 cd/m²):x:±0.0015 y:±0.001/ u':±0.0014 v':±0.0006


Wide dynamic measurement range(CS-3000HDR)

Today's display screens are constantly upgrading to provide more realistic and high-quality images. To meet the measurement needs of these excellent displays, commonly used standard values are measuredWith a measurement angle of 1 °, CS-3000HDR can achieve accurate measurements within a wide dynamic range from low to high brightness. In addition to the current mainstream LCD and OLED, it also supports standard value measurement for HDR displays such as Micro LED and Mini LED.
Accuracy guarantee brightness range (based onBrightness measurement at a measurement angle of 1 °: 0.0001--100,000cd/m²

Electric switching1 °/0.2 °/0.1 ° measurement angle (CS-3000)CS-3000HDR)

According to the required measurement size, fromChoose from three measurement angles. Electric switching can be performed through communication commands, supporting fully automatic testing systems.

·Measure distance and measurement area (unit: mm)

CS-3000HDR/CS-3000分光辐射亮度计

*The measurement distance is calculated from the end of the objective lens.


·Schematic diagram and application example of the measurement area at a distance of 500mm

CS-3000HDR/CS-3000分光辐射亮度计


Shorten measurement time

The display screenA series of tests under low brightness conditions, such as gamma measurement, low brightness uniformity measurement, and I-V-L measurement of display screen materials, may take several hours or more to complete if traditional spectrophotometers are used. This is a major issue in both research and development, production, and quality management. The CS-3000 is equipped with the following new features, which greatly reduce the measurement time of Gamma by less than 1/4 of the previous time.

CS-3000HDR/CS-3000分光辐射亮度计


<High speed mode>

FAST mode: The measurement integration time is approximately 1/6 of NORMAL.
SUPER FAST1 mode: The measurement integration time is approximately 1/20 of NORMAL.
SUPER FAST2 mode: The measurement integration time is approximately 1/90 of NORMAL.
*The above parameters are not applicable to CS-2000 Plus

<INTELLIGENT DARK Function>

By measuring the light source and dark current every time and calculating the difference in measurement values to eliminate the influence of dark current fluctuations, the spectrophotometer can achieve higher accuracy. Dark current measurement may sometimes be skipped to save measurement time, but the dark current value may fluctuate with the passage of time and other changes. At this point, the fluctuation will be superimposed on the previously calculated light intensity, resulting in a decrease in measurement accuracy.The INTELLIGENT DARK function can use compensation information from sensors to compensate for fluctuations while skipping dark current measurements, thereby reducing measurement time while maintaining high accuracy.

CS-3000HDR/CS-3000分光辐射亮度计


<Light function detection and setting function>(CS-3000)CS-3000HDR)

The function of detecting the luminous frequency of the display screen and setting the measurement integration time to an integer multiple of it. It can avoid the mismatch between the measurement integration time and the emission frequency without extending the timePoor repeatability caused by 'synchronization deviation'.

Konica MinoltaCS-3000HDR/CS-3000 spectrophotometerProduct Specifications

CS-3000HDR/CS-3000分光辐射亮度计


System Diagram

CS-3000HDR/CS-3000分光辐射亮度计


Data processing softwareCS-S30

1Controlled by computerThe software for measuring CS-3000 series.
2It can be operated intuitively through an easy to understand visual display.

<Features>

1compatibleWindows/Mac can set and execute various measurement functions to display measurement values in charts.
2In addition to brightness, chromaticity, and spectrogram, it also supportsL * a * b * display.
3Apart from the usualIn addition to CIE1931 (2 ° viewing angle), CIE1964 (10 ° viewing angle) and CIE170-2:2015 (2/10 viewing angle) can also be set.
4Any color matching function can also be used to calculate chromaticity values.

*If there are any changes to the above specificationsNo further notice will be given.