COSMOSIL 5C18-MS-II chromatographic column

NegotiableUpdate on 05/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The COSMOSIL 5C18-MS-II chromatographic column is one of the most balanced and basic performance columns in the COSMOSIL series (with fast peaks, sharp peak shapes, and high theoretical plate numbers for separating alkaline compounds and metal coordination compounds). Its quality is stable and reliable, with rich analysis data and simple analysis condition settings, making it the preferred choice for reverse phase columns.

Product Details

COSMOSIL 5C18-MS-II chromatographic columnIt is a chromatographic column in the COSMOSIL series with excellent balance and basic performance (fast peak, sharp peak shape, and high theoretical plate number when separating alkaline compounds and metal coordination compounds). Its quality is stable and reliable, with rich analysis data and simple analysis condition settings, making it the preferred choice for reverse phase columns.

  • Multi purpose C18 chromatographic column

  • High reproducibility

  • Wide range of applications


COSMOSIL 5C18-MS-II chromatographic columnSeparation characteristics

COSMOSIL 5C18-MS-II分离特性


reproducibility

If an insufficiently capped C18 chromatographic column is used to analyze alkaline compounds, you will spend a lot of time adjusting the mobile phase. You may need to:

Three or more organic phases and buffer salts

Ionic reagents or additives

Buffer salts with different pH values

In addition, complex flow is a test of relative reproducibility.
Due to the use of a new capping technology, COSMOSIL 3C-18 only requires a simple mobile phase to achieve excellent peak shapes and separation.


Usage information

chromatographic column 3μm 3C18-EB
Inner diameter (mm) 1.0 2.0 3.0 4.6
Column length (mm) ALL ALL ALL 10 50-250
Factory solvent Acetonitrile/water=60/40
flushing method
  1. Method for removing buffer, salt, and acid from the chromatographic column: Rinse with a mobile phase free of buffer, salt, and acid for 10-15 minutes.
    Example: When the mobile phase is methanol/phosphate buffer (20mmol/L)=50/50, rinse with methanol/water=50/50

  2. The method of flushing the attached substances in the chromatographic column and the solution when the baseline is unstable

  • When the sample is not protein, rinse with methanol or *.

  • When the sample is protein, use 0.1%C2HF3O2Rinse with 50-70% acetonitrile/water



Shenzhen Dongfang Lantai Technology is a high-tech company specializing in the import of laboratory analytical instruments and equipment such as gas chromatography, liquid chromatography, electronic balance, electrochemical instruments, general instruments and equipment, chromatography columns, reagents, standards, etc. At the beginning of its establishment, the company insisted on focusing on the analysis industry and was committed to introducing domestic and foreign analytical instruments to a wide range of domestic users. Currently, the company's users have spread to scientific research institutions, colleges and universities, hospitals, chemical industry, food, medicine, agriculture, mining, power, metallurgy and other industries and units.