The JQ-101X COD automatic digestion reflux instrument (12 tubes) mainly consists of four parts: the body, reflux condenser tube, fan, and electric furnace. It uses microcomputer technology to control the heating of the electric furnace plate and fan at a fixed time, and can simultaneously heat 12 reflux devices. Ceramic plate heating, better effect, bottle rack protection, safer

Product Details

JQ-101X typeCOD automatic digestion reflux analyzer(12 tubes)

JQ-101X COD automatic digestion reflux analyzer (12 tubes)By using microcomputer technology and reasonable design, 12 150ML cylindrical bottles can be heated and refluxed for digestion simultaneously. *According to the HJ828-2017 national standard method, high-quality electric furnace wire is selected, with the correct heating power and a slight boiling time of 2 hours. The COD digester uses a specially designed electric furnace plate for heating, with uniform surface heating and fast heating and cooling rates. At the same time, if the sample solution is accidentally dropped, it will evaporate naturally, which can reduce the damage to the instrument caused by improper operation. Standard COD digesterThe digestion time can be set, and a countdown to the digestion time can be displayed. After digestion is complete, the instrument automatically stops heating, and the instrument fan continues to work to assist in sample cooling. It can be left unattended.

JQ-101X typeCOD automatic digestion reflux analyzerUsing glass burr reflux tubes instead of spherical reflux tubes, and replacing circulating water cooling methods with air and water cooling technologies, the operation is more convenient. The cooling part is mainly completed by burr condensation tube water cooling and fan air cooling. The upper part of the condensation tube is spherical with 2 bubbles for better cooling effect. The catalyst is added here to prevent the instantaneous volatilization of light components in the sample and can be covered with a volatilization cap. The lower part is in the shape of a 'burr', with two opposing 'cold bubbles' extending from the wall of the condenser tube on a flat surface, which increases the cooling area and blocks the passage of volatile substances and vapors compared to a simple spherical condenser tube. In addition, the dual effect of cooling water and internal fan in the upper spherical reflux tube ensures the reflux cooling of the sample. The JQ-101X standard COD digestion device uses an inserted burr reflux tube, which is safer and more stable to use.

Technical Specifications:

Measurement range:10-700mg/L (measured after dilution of water samples greater than 700mg/L)

Dissolving time: 10 minutes to 2 hours and 30 minutes (users can choose their own heating time)

Measurement error: The relative standard deviation of potassium hydrogen phthalate standard solution (500mg/L) shall not exceed 5.0%;The relative standard deviation of industrial organic wastewater (500mg/L) is not more than 8.0%

Environmental temperature: ≤ 40 ℃

Sample size for digestion: 12 150ml cylindrical bottles, heated and digested in three rows for easy sampling.

Heating power: ≤ 1200W (AC 220V, 50HZ)