Phone
13033172169
-
Address
Building 10, storefront 4, Dayuan Community, Daguan District, Anqing City, Anhui Province
Anqing Changjia Electronic Products Trading Co., Ltd
13033172169
Building 10, storefront 4, Dayuan Community, Daguan District, Anqing City, Anhui Province
|
Gas detection
|
Fluorine gas/F2
Optional: Can simultaneously detect any 1-6 gas concentrations and temperature/humidity, expandable to 18 gases
|
|||||||
|
Testing Scope
|
0-1、10、20、50、200ppm
|
|||||||
|
resolution
|
0.001ppm、0.1ppm
|
|||||||
|
Detection Principle
|
electrochemistry
|
|||||||
|
Sensor lifespan
|
2-3year
|
|||||||
|
Detection method
|
Built in pump suction, flow rate 800 milliliters per minute
|
|||||||
|
display mode
|
3.5A large screen with a resolution of 320X240 inches and high-definition color display
|
|||||||
|
detection accuracy
|
≤± 2% F.S (higher precision can be customized)
|
uncertainty
|
≤±2%
|
|||||
|
Linearity
|
≤±2%
|
Repeatability
|
≤±2%
|
|||||
|
alarm method
|
Sound and light alarm, visual alarm, sound and light+visual alarm, turn off alarm
|
|||||||
|
response time
|
T90≤ 20 seconds
|
recovery time
|
≤ 30 seconds
|
|||||
|
working power supply
|
DC3.6V
|
|||||||
|
battery capacity
|
3.6VDC, 6000mA rechargeable polymer battery with overcharge, overdischarge, overvoltage, and short circuit protection functions
|
|||||||
|
Usage environment
|
Temperature -40 ℃~+70 ℃; Relative humidity ≤ 0-99% RH
|
|||||||
|
Sample gas temperature
|
-40℃~+70 ℃, optional high temperature sampling and cooling filter handle or high temperature and high humidity pretreatment system can detect flue gas concentration up to 1300 ℃
|
|||||||
|
temperature measurement
|
-40℃~+120 ℃ accuracy 0.5 ℃
|
Humidity measurement
|
0-100%RHAccuracy 3% RH
|
|||||
|
data storage
|
Standard capacity of 100000 pieces of data, optional CF card and USB storage, unlimited capacity, supports local viewing, deletion or data export,
Free upper computer communication software, storage function defaults to off state, can be set to on state, storage time interval can be set arbitrarily
|
|||||||
|
communication interface
|
Infrared, USB, RS232 automatic recognition
|
|||||||
|
printer
|
Optional, built-in micro printer or external micro wireless infrared printer
|
|||||||
|
wireless transmission
|
Optional, data can be wirelessly transmitted to monitoring devices such as mobile phones, remote monitoring centers, and monitoring computers. The upper computer can be used for data analysis, storage, printing, and other functions on the computer
|
|||||||
|
Interface language
|
Chinese or English can be set, default Chinese interface
|
|||||||
|
Explosion proof type
|
intrinsically safe
|
Explosion-proof marking
|
Explosion proof Exd Ⅱ CT6
|
|||||
|
Protection level
|
IP66Rain and water splashes, dust prevention
|
|||||||
|
Overall dimensions
|
230×210×120mm(L×H×W)
|
weight
|
2.5Kg
|
|||||
|
Standard Appendix
|
Instruction manual, certificate of conformity, warranty card, USB charger (including data cable), high-end aluminum alloy instrument box, CD (upper computer communication software), 40cm stainless steel sampling handle (1-meter hose)
|
|||||||
|
Optional accessories
|
Built in micro printer, external micro wireless infrared printer, temperature and humidity measurement function, USB storage, wireless data communication function, high temperature sampling and cooling filter handle, high temperature and high humidity pre-processing system, external remote sampling pump, multiple humidity and dust filters, 1.2m extendable sampling handle (1-meter hose)
|
|||||||
|
Application scenarios
|
All occasions requiring gas concentration detection, such as petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, air treatment, scientific research institutions, etc
|
|||||||