CHI760F series double potentiostat

NegotiableUpdate on 05/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The CHI760F series and CHI700F series are universal double potentiometers that can simultaneously control the potential of two working electrodes in the same electrolytic cell. Their typical application is the rotating ring disk electrode, and they can also be used in other situations where dual working electrodes are required. Dual potentiometers can only be used for potential control and current measurement of two working electrodes in the same solution, rather than two independent potentiometers.

Product Details

CHI760F series double potentiostatIt is a universal dual potentiostat that can simultaneously control the potential of two working electrodes in the same electrolytic cell. Its typical application is the rotating ring disk electrode, and it can also be used in other situations where dual working electrodes are required. Dual potentiometers can only be used for potential control and current measurement of two working electrodes in the same solution, rather than two independent potentiometers. The instrument contains a fast digital signal generator, a direct digital signal synthesizer for high-frequency AC impedance measurement, a dual channel high-speed data acquisition system, a potential current signal filter, multi-stage signal gain, iR drop compensation circuit, a dual potentiostat, and a constant current meter (CHI760F). The potential range of both channels is+/-10V. The current range (sum of two channel currents) is ± 250mA.

The CHI700F series adds a circuit board based on the CHI600F, which includes a second channel potential control circuit, current voltage converter, sensitivity selection, three gain stages, and a second-order low-pass filter with eight orders of magnitude variable frequency range. CHI700F can control the potential of two working electrodes, allowing for the measurement of dual working electrodes using experimental techniques such as cyclic voltammetry, linear sweep voltammetry, step wave voltammetry, chronoamperometry, differential pulse voltammetry, conventional pulse voltammetry, square wave voltammetry, and time current curve. When used as a dual potentiostat for measurement, the potential of the second working electrode can be maintained at an independent constant value, or it can be scanned or stepped synchronously with the first working electrode. In cyclic voltammetry, it is also possible to scan while maintaining a constant potential difference with the first working electrode. The CHI700F series is also a very fast instrument. The update rate of the signal generator is 10MHz, and two synchronous 16 bit high-resolution and low-noise analog-to-digital converters are used for data acquisition. The maximum rate for dual channel simultaneous sampling is 2.5MHz. When the scanning speed of cyclic voltammetry is 1000V/s, the potential increment is only 0.1mV. When the scanning speed is 5000V/s, the potential increment is 1mV. For example, the measurement frequency of AC impedance can reach 3MHz, and the frequency of AC voltammetry can reach 10KHz. The instrument also has an external signal input channel, which can record both electrochemical signals and external input voltage signals, such as spectral signals. This is extremely convenient for experiments such as spectroscopic electrochemistry.

CHI700F not only allows the potential of the second working electrode to be independently controlled at a constant potential, but also allows the potential of the second working electrode to be scanned or stepped synchronously with the first working electrode. During dual channel synchronous scanning, the maximum scanning speed can reach 10000 V/s. When using a dual channel synchronous step, the minimum sampling interval can reach 0.4 microseconds. As the CHI700F series is an extension of the CHI600F series, the former fully covers the latter's functions and has more testing capabilities. The CHI700F series also allows for a four electrode system for electrochemical measurements at liquid/liquid interfaces.

The 700F series is an iterative upgrade product of the 700E series. After the upgrade, it has a faster data acquisition speed and uses a dual channel synchronous ADC with 16 bit resolution and 2.5MHz. Previously, the dual channel synchronous ADC was 1MHz.

CV testing supports a sampling interval of 1mV at a scanning speed of 2500V/s. Previously, the sampling interval was 1mV at a scanning speed of 1000V/s.

The minimum sampling interval for CA has been reduced from 1 microsecond to 0.4 microsecond, with dual channel synchronization.

The new model will have faster data transfer speed under the USB 3.0 interface. The scanning speed of real-time data transmission for CV has been increased from 3V/s to 12V/s. The real-time data transmission interval of i-t and CA technology has been reduced from 0.0003333 seconds to 0.0001 seconds.

The frequency of AC impedance is increased to 3MHz.

We have added current interruption iR compensation, constant current intermittent titration technology (GITT), and constant potential intermittent titration technology (PITT).

When the CHI700F series is used as a single potentiostat, its performance is the same as that of the CHI600F series. If connected to CHI200B microcurrent amplifier and shielding box, the first channel can measure a current of 1pA or lower. CHI700F can also be connected to CHI680D high current amplifier to obtain larger current and slot voltage, but it can only be used for single channel measurement.

CHI760F series double potentiostatIn order to meet different application needs and funding conditions, the CHI700F series is divided into multiple models. Different models have different electrochemical measurement techniques and functions, but the basic hardware parameter indicators and software performance are the same. CHI700F and CHI710F are basic types, CHI720F and CHI730F are comprehensive electrochemical analyzers, while CHI750F and CHI760F are more advanced electrochemical workstations.

双恒电位仪CHI760F系列

Hardware parameter indicators


Constant potential meter/double constant potential meter

·Zero resistance ammeter

·2, 3, 4 electrode structure

·Floating ground wire or on-site

·Maximum potential range of two channels: ± 10 V

·Maximum current: ± 250 mA continuous (sum of two channel currents), ± 300 mA peak

·Slot pressure: ± 13 V

·Rise time of potentiostat: less than 1 μ s, usually 0.8 μ s

·Constant potential meter bandwidth (-3 decibels): 1 MHz

·Range of applied potentials: ± 10 mV, ± 50 mV, ± 100 mV, ± 650 mV, ± 3.276 V, ± 6.553 V, ± 10 V

·Potential resolution applied: 0.0015% of the potential range

·Accuracy of applied potential: ± 1 mV, ± 0.01% of full scale

·Applied potential noise:<10 mV mean square root

·Measurement current range: ± 10 pA to ± 0.25 A, 12 ranges

·Measurement current resolution: 0.0015% of the current range, with a minimum and minimum of 0.3 fA

·Accuracy of current measurement: 0.2% for current sensitivity from 1e-3A/V to 1e-7A/V, and 1% for other ranges

·Input bias current:<10 pA


Constant current meter

·Constant current range: 0.3 nA -250 mA

·Current resolution applied: 0.03% of the current range

·Measurement potential range: ± 0.025 V, ± 0.1 V, ± 0.25 V, ± 1 V, ± 2.5 V, ± 10 V
·Measurement potential resolution: 0.0015% of the measurement range

·Accuracy of applied current: ± 20pA, 0.3% for currents 3e-7A to 3e-3A, and 1% for other ranges


Electrometer: Potentiometer

·Reference electrode input impedance: 1e12 ohms

·Reference electrode input bandwidth: 10 MHz

·Reference electrode input bias current:<=10 pA @ 25 ° C


Waveform generation and data acquisition system

·Fast signal generation update rate: 10 MHz, 16 bit resolution

·Fast data acquisition system: 16 bit resolution ADC, dual channel synchronous sampling, sampling rate of 2.5MHz

·The maximum sampling rate of the external signal recording channel is 2.5M Hz


Attachment

·Electrode wire

·USB communication cable

·Power cord

experimental parameters

·CV and LSV scanning speeds: 0.000001V/s to 10000 V/s, dual channel synchronous scanning and sampling up to 10000 V/s

·Potential increment during scanning: 0.1 mV (at a scanning speed of 1000 V/s)

·Pulse width of CA and CC: 0.0001 to 1000 seconds

·Minimum sampling interval for CA: 0.4 ms, dual channel synchronization

·Minimum sampling interval for CC: 0.4 ms

·CC analog integrator

·Pulse width of DPV and NPV: 0.001 to 10 seconds

·SWV frequency: 1 Hz to 100 kHz

·Minimum sampling interval for i-t: 0.4ms, dual channel synchronization

·ACV frequency range: 0.1 Hz to 10 kHz

·SHACV frequency range: 0.1 Hz to 5 kHz

·FTACV frequency range: 0.1Hz to 50Hz, can simultaneously obtain ACV data for fundamental, second harmonic, third harmonic, fourth harmonic, fifth harmonic, and sixth harmonic

·AC impedance: 0.00001Hz to 3 MHz

·AC impedance waveform amplitude: 0.00001 V to 0.7 V root mean square value


other features

·Automatic or manual iR reduction compensation (positive feedback and current interruption method)

·Current measurement bias: Full scale, 16 bit resolution, 0.003% accuracy

·Potential measurement bias: ± 10V, 16 bit resolution, 0.003% accuracy

·External potential input

·Analog output of potential and current

·Cut off frequency of controllable potential filter: 1.5 MHz, 150 KHz, 15 KHz, 1.5 KHz, 150 Hz, 15 Hz, 1.5 Hz, 0.15 Hz

·Cut off frequencies of controllable signal filters: 1.5 MHz, 150 KHz, 15 KHz, 1.5 KHz, 150 Hz, 15 Hz, 1.5 Hz, 0.15 Hz

·Rotating electrode control voltage output (CHI730F or above): 0-10V for speeds from 0-10000 rpm, 16 bit resolution, 0.003% accuracy, requires certain rotating electrode devices to work

·Macro commands can be used to control digital input and output lines

·Internal flash memory can quickly update programs

·USB port data communication

·Electrolytic cell control: nitrogen supply, stirring, tapping (requires special electrolytic cell system)

·CV digital simulator and fitter. User defined reaction mechanism (CHI730F or above) or predefined reaction mechanism (other models)

·AC impedance simulator and fitting device (models with AC impedance measurement function)

·Maximum data length: 256K-16384K points selectable

·Instrument dimensions: 37 cm (width), 23 cm (depth), and 12 cm (height)

双恒电位仪CHI760F系列

Comparison of different models of CHI700F series instruments

function

700F

710F

720F

730F

750F

760F

Cyclic voltammetry (CV)*

l

l

l

l

l

l

Linear sweep voltammetry (LSV)&*

l

l

l

l

l

l

Step wave voltammetry (SCV)#&*




l

l

l

Tafel图 (TAFEL)




l

l

l

Chronoamperometry (CA) method*

l


l

l

l

l

Chronoelectricity method (CC)

l


l

l

l

l

Differential pulse voltammetry (DPV)#&*


l

l

l

l

l

Conventional pulse voltammetry (NPV)#&*


l

l

l

l

l

Differential conventional pulse voltammetry (DNPV)#&






l

Square wave voltammetry (SWV)&*



l

l

l

l

Communication (including phase sensitive) voltammetry (ACV)#&$




l

l

l

Second harmonic alternating current (phase sensitive) voltammetry (SHACV)#&$




l

l

l

Fourier transform alternating current voltammetry (FTACV)






l

Current time curve (i-t)*




l

l

l

Differential Pulse Current Detection (DPA)






l

Double Differential Pulse Current Detection (DDPA)






l

Triple pulse current detection (TPA)






l

Integral Pulse Current Detection (iPad)






l

Controlled potential electrolytic Coulombic method (BE)

l


l

l

l

l

Fluid dynamics modulation voltammetry (HMV)





l

l

Scan Step Hybrid Method (SSF)





l

l

Multi potential step method (STEP)





l

l

Constant potential intermittent titration method (PITT)






l

Impedance Measurement (IMP)





l

l

Impedance Time Measurement (IMPT)





l

l

Impedance potential measurement (IMPE)





l

l

Chronopotentiometry (CP)






l

Current scanning chronopotentiometry (CPCR)






l

Multiple current step method (ISTEP)






l

Constant current intermittent titration method (GITT)






l

Potentiometric Stripping Analysis (PSA)






l

Electrochemical Noise Measurement (ECN)






l

Open circuit voltage time curve (OCPT)

l

l

l

l

l

l








Constant current meter






l

RDE control (0-10V output)

l

l

l

l

l

l

Arbitrary Reaction Mechanism CV Simulator




l

l

l

Preset reaction mechanism CV simulator

l

l

l




Communication impedance digital simulator and fitting program





l

l

Price (CNY)

Negotiable

Negotiable

Negotiable

Negotiable

Negotiable

Negotiable



Note: including corresponding polarography and stripping voltammetry. Special static mercury electrodes or hammers are required for use in polarography.

Can obtain selected phase data

Two channel (dual potentiostat mode) available

The price does not include computers. The warranty period for the instrument is one year.