- Phone
-
Address
4th Floor, Building 1, No. 9 Xiyuan 2nd Road, Xihu District, Hangzhou City, Zhejiang Province
Zhejiang Hongpu Light Color Technology Co., Ltd
4th Floor, Building 1, No. 9 Xiyuan 2nd Road, Xihu District, Hangzhou City, Zhejiang Province
HPCS6500Building energy-saving testing equipmentContains the following components:
1) High precision spectral analyzer 380-780nm
2) Customized fiber optic
3) Precision DC stabilized constant current power supply 60V, 5A
4) Precision AC variable frequency test power supply 1KVA
5) Harmonic type electrical parameter measuring instrument

HPCS6500Building energy-saving testing equipmentMeasurable parameters:
Test parameters such as relative spectral power distribution, chromaticity coordinates, dominant wavelength, color purity, peak wavelength, color temperature, color rendering index, half width, luminous flux (with integrating sphere), radiated power, red ratio, color tolerance, etc., to meet the CIE requirements for light and color measurement.

Technical Indicators:
1. Grating: High performance precision diffraction concave grating;
2. Detector: HAMAMATSU (Hamamatsu, Japan) back illuminated precision array CCD;
3. Integral time: 10 μ s-10s;
4. Main optical parameters:
Wavelength range: 350nm-800nm (expandable to UV 200nm or IR 1100nm)
Wavelength accuracy: ± 0.3nm;
Optical bandwidth: 2nm;
Stray light:<0.1%
Color standard accuracy: ± 0.0015 (under standard color light), ± 0.0003 (under standard A light source);
Color coordinate repeatability: ± 0.0002x, ± 0.0003y (constant temperature blue LED)
Luminous flux measurement range: 0.01 lm to 20000 lm (with different integrating spheres);
Luminous accuracy: Level 1
5. A/D conversion: 16 bit 1.25MHz AD;


2) Precision DC stabilized constant current power supply
1. Output range: voltage 0-60.000V, current 0-5.000A; maximum power: 150W
2. Ampere meter range: 0.5A/1A/2.5A/5A
3. Measurement range of voltmeter: 5V/10V/30V/60V
4. Resolution of ammeter: 0.0001A;
5. Accuracy of ammeter: ± (0.02% reading+0.01% range+1 word)
6. Accuracy of current output: ± (0.05&reading+0.2mA)

3) Precision AC variable frequency test power supply
1. Output power: 1KVA
2. Output voltage: Output range: 0V~150V; 0V~300V
3. Harmonic distortion: ≤ 2% resistive load at full load
4. Output current (1) Maximum output current: 8.4A (0V~150V)/4.2A (0V~300V)
5. Adapt to complex loads: resistive loads, inductive loads, rectifier loads (for inductive and rectifier loads, they should be downgraded for use)
6. Output frequency

4) High precision electrical parameter measuring instrument
1. Accuracy of ammeter: ± (0.4% reading+0.1% range+1 word)
2. Resolution of ammeter: 0.001A (0.001A~9.999A)
0.01A (10.00A~99.99A)
3. Ampere meter range: 1A/5A/10A
4. Voltage meter accuracy: ± (0.4% reading+0.1 range+1 word)
5. Resolution of voltmeter: 0.1V
6. Range of voltmeter: 30V/70V/150V/300V
7. Measurement accuracy of power meter: ± [0.4% reading+(0.1/PF)% range+1 word]
8. Resolution of power meter: 0.1W (0.1W~999.9W); 1W (over 1.000KW)
9. Power factor measurement accuracy: ± [0.001/reading+0.001 × (1+0.02f)+1 word]
10. Power factor meter force: 0.001
11. Total harmonic distortion of current, total harmonic voltage, total harmonic current, total harmonic power, effective values and relative values of 2-50th harmonics.