Beidou Star Instrument Portable Gas Composition Analyzer

NegotiableUpdate on 06/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The portable gas composition analyzer pGas2000-CGA-4s01 from Beidou Satellite Instrument is equipped with a built-in single-chip microcomputer and hardware system design, and all data can be saved in case of power failure. Each instrument provides professional analysis/testing techniques and maximizes the solidification of professional methods. The BD5 tester enables most instruments to provide full range testing, eliminating the hassle of range selection. Conventional setup includes 6 channels for gas and 1 channel for temperature testing and 1 channel for humidity testing. It can expand testing for up to 23 common gases of different species.

Product Details

Beidou Star Instrument Portable Gas Composition AnalyzerpGas2000-CGA-4s01Testing parameters and technical indicators:

Model

Professional analysis system

repeatability

accuracy

stability

technology

notes








pGas2000-CGA-4s01

Gas detector

CO:020%;

20-100%;

H2:0-100%

HC:0-100%;

H2S:0-1000ppm

H2O:100ppm-3%

Calorific value range:

±0.1%FS


<2%R

<±0.1%abs

<±1%R


<±1%FS

<5%R

<2%FS

<±0.25%abs

<±2%R


<1% in 20s, constant temperature

comprehensive

Gas calorific value analysis


Portable gas composition analyzerTechnical Parameter

  • Response time:<10ms

  • Long term stability: ± 10%/year (generally)

  • Host resolution: 0.1% FS

  • Sensor accuracy: ± 1-2% reading (general)

  • Probe response time:<3mins (T90)

  • Instrument usage environment: Temperature: -10~60Humidity: 10%~90% R (no condensation)

  • Instrument storage environment: Temperature: 0~4Humidity: 10%~80% R (no condensation)

  • Probe sampling requirements: Temperature: 0~40Pressure:<1.1 kgf/cm2

  • Instrument power supply: 12V rechargeable battery

  • Instrument size: 400 × 300 × 200mm

  • Instrument weight: 4.5Kg

Portable gas composition analyzerPurpose: Gas quality testing

Portable gas composition analyzerapplication

  • Natural gas, also known as gas field gas or water shield natural gasGas, petroleum gas, condensate gas field gas analysis

  • Composition of liquefied petroleum gasrapid analysis

  • Urban pipeline gas trading

  • gasMain componentsrapid analysis

  • Coal mine gasMain componentsanalysis

  • gas hydratedetection

Portable gas composition analyzerTechnical advantages

  • Standard built-in base gashydrocarbonHC/methane CH4/water vapor H2O sensor, equipped with hydrogen H2/hydrogen sulfide H2S/oxygen O2/carbon dioxide CO2/carbon monoxideCO/Methyl mercaptan CH3SH/tetrahydrothiophene TH/sensor is available for selection,Each sensor responds to different gases,Meet various on-site requirements.

  • Conventional setup includes 6 channels for gas and 1 channel for temperature testing and 1 channel for humidity testing.

  • Support DKA (dual standard method) standard sample or substitute calibration, as well as single point pure inert gas calibration.

  • Providing cross interference gas neural network correction mode analysis technology has solved the problem of cross interference in gas detection.

Portable gas composition analyzerfunction

  • The gas sensor adoptsElectrochemical method, infrared photometer method.

  • You can choose according to the actual situationgasDetection parametersSimultaneously detecting multiple gases on one instrument.

  • Equipped with printingperformableOn siteLaboratory testing requires.

  • Pump sampling and sampling.

  • The sensor operates in real-time and continuously detects the working mode.

  • Power undervoltage and power failure alarm.

  • Quickly detect parameters and temperature values, and perform temperature correction and cross correction.

  • Inert gas software zeroing, standard sample or substitute calibration.

  • All operation keyboard settings, window prompts.

  • On site LCD 4 × 16 character rotating display of multiple environmental parameters.

  • The RS232/RS485 communication interface supports serial communication and can be connected to a computer.

  • Users can also calibrate or calibrate themselves.

Portable gas analyzerComplete set of components


Instrument standard configuration

pGas2000-NGMain analyzer

temperature probe

Humidity probe

Standard gas sensor

Rechargeable Battery

charger

Sampling pump

Sampling gun

Aluminum alloy instrument box


Options

Micro printer

Expand gas sensors

Pipe joint fittings

Electric sampling pump

Electric sampling pump

Electric sampling pump

Electric sampling pump

pressure reducer

current regulator

electronic thermostat

filter

flowmeter

Electronic Flow Meter


Portable gas analyzerTypical User

China Steel Group Refractory Materials Co., Ltd

Hubei Xiangfan Sinopec Pipeline Storage and Transportation Company

Chengdu Zhongdian Technology Co., Ltd

YiehPhui(China)Technology Materials Co., Ltd

Inner Mongolia Xingtong Coal Industry Co., Ltd

Shandong Lantian Board Industry Co., Ltd

Huafeng Electronics Co., Ltd

Zhongshan Yong'an Electric Power Co., Ltd

anhui university of technology


Common Gas Composition Table

Composition%

Applicationspecies class

blast furnace gas

coke oven gas

producer gas

Converter gas

natural gas

methane

Hydrocarbons

carbon monoxide

hydrogen

nitrogen

carbon dioxide

Calorific value (kcal/Nm)3

Heavy (kg/Nm)3

Ignition point(

main properties




27~30

1.5~1.8

55~57

8~12

850~950

1.295

700

Colorless And Odorless

There is ju poison

burn and explode

20~30

2

7

58~60

7~8

3~3.5

3900~4400

0.45~0.55

600~650

colourless

Odorous and toxic

burn and explode

3~6

≤0.5

26~31

9~10

55

1.5~3.0

1400~1700

1.08~1.25

700

Colored, odorous, and toxic

burn and explode



60~80



15-20

1800~2200


650~700

Colorless, odorless, and toxic

burn and explode

~100






8500~90000

0.7~0.8

550

Colorless with garlic odor

Suffocating anesthesia

Extremely flammable and explosive

Beidou Star Instrument Portable Gas Composition AnalyzerPGas2000-CGA-4s01 Manufacturer's quotation