Welcome Customer !

Membership

Help

Hangzhou Jiuhuan Fuqi Industrial Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Battery solidification room

NegotiableUpdate on 05/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The JH-G battery curing chamber products are widely used in product quality inspection institutes, battery manufacturers in various provinces and cities, as well as telecommunications, power systems, and motorcycle, electric vehicle, and automobile manufacturers that use batteries to conduct quality testing and monitoring of batteries. Our company has developed a new generation of temperature and humidity control and regulation equipment, with stable and reliable product quality.

Product Details

1. Battery solidification roomTechnical parameters:
1.1 Temperature control range: Room temperature~100 ℃
1.2 Temperature control accuracy: ± 1 ℃
1.3 Temperature uniformity deviation: ≤ 2 ℃
1.4 Humidity control range: 1-99.9% RH
1.5 Humidity control accuracy: ± 2% RH
1.6 Humidity uniformity deviation: ≤ 3% RH
1.7 Effective volume: 3950 × 2280 × 2500mm
1.8 Dimensions: 4750 × 2480 × 4500mm
2. Battery solidification roomTechnical performance:
2.1 The curing and drying processes of the raw board can be completed automatically in one go, or can be operated independently as a single item.
2.2 The touch screen PLC is used for closed-loop control of various parameters of the system, displaying the operating status and real-time parameters of each curing and drying chamber, recording historical parameters (curves), and immediately sounding an audible and visual alarm when the system runs abnormally, and prompting the operator to handle the fault. Operated in Chinese, with semi-automatic and automatic control functions.
2.3 Imported temperature and humidity sensors have the characteristics of high temperature resistance, anti fog and acid resistance, and long service life.
2.4 Adopting efficient atomizing nozzles and three-dimensional air distribution method for hot air circulation, the circulating fan adopts variable frequency control, and the air volume is infinitely set on the touch screen. Different circulating air volumes can be selected for curing and drying stages to ensure uniform humidity and temperature throughout the room.
2.5 Each unit can store 10 sets of different curing and drying process parameters, with each set consisting of no less than 7 segments.
2.6 Use steam to heat the circulating air through a heat exchanger or electric heating method to provide the required heat.
3.Working conditions:
3.1 Power supply: 380V ± 10% 50Hz
3.2 Environmental temperature: 0 ℃ -+40 ℃
3.3 Relative humidity: 40% -85% RH
3.4 Cooling water: 0.2-0.3 bar
3.5 Compressed air: 0.4-0.5 Mpa
3.6 Steam: 0.5-0.6Mpa
3.7 Electric heating: 380V/220V 50Hz