The Burkert Baode solenoid valve imported from Germany does not work after being powered on: check if the power wiring is poor → rewire and connect the connectors; Check if the power supply voltage is within the working range ->adjust to the normal position range; Check if the coil is detached → re weld; Coil short circuit → replace coil; Is the working pressure difference inappropriate? Adjust the pressure difference or replace the corresponding Burkert solenoid valve; If the fluid temperature is too high, replace the corresponding Burkert solenoid valve Impurities cause the main valve core and moving iron core of the Burkert solenoid valve to get stuck → Clean it

Product Details

  Imported Burkert electromagnetic valve from Germany00357605 Shanghai Forest Layer provides a large supply
Installation precautions manual for Burkert solenoid valve
1、 Dielectric characteristics of German Baode Burkert solenoid valve
1. Select different varieties of Burkert solenoid valves for gas, liquid, or mixed states. For example, ZQDF is used for air, ZQDF-Y is used for liquid, and ZQDF-2 (or -3) is used for steam, otherwise it may cause misoperation. The ZDF multifunctional solenoid valve can be used for both gas and liquid. Products with different specifications of medium temperature, otherwise the coil will burn out and the seal will become old
Transformation seriously affects lifespan.
2. The viscosity of the medium is usually below 50cSt. If the diameter exceeds this value, special orders can be made with ZDF series multifunctional Burkert solenoid valves for diameters greater than 15mm. High viscosity Burkert solenoid valve with a diameter less than 15mm.
3. When the cleanliness of the medium is not high, a backwash filter valve should be installed in front of the Burkert solenoid valve. When the pressure is low, a direct acting diaphragm Burkert solenoid valve such as CD-P can be used.
4. If the medium flows in a directional manner and does not allow reverse flow, ZDF-N and ZQDF-N need to flow in both directions, please make special requirements.
5. The medium temperature should be selected within the allowable range of the Burkert solenoid valve.
  Selection parameters and installation of Burkert Baode solenoid valve imported from Germany
1. The voltage specifications should preferably use AC220V and DC24, which are more convenient.
2. Burkert solenoid valve can be normally closed, normally open, or continuously energized depending on the duration of continuous operation
2. If the opening time is short or the opening and closing time is not long, choose the normally closed type.
3. However, for some working conditions used for safety protection, such as furnace and kiln flame monitoring, the normally open type cannot be selected, and the long-term electrified type should be selected.
4. Burkert solenoid valve provides auxiliary functions according to the environment, including explosion-proof, check, manual, waterproof fog, water shower, and diving
1. Installation position: Ensure that the regulating valve is installed at the low or highest point of the pipeline to facilitate normal fluid flow and facilitate maintenance and overhaul
2. Connection: Ensure that the connection of the regulating valve meets the pipeline standards, is leak free, and pay attention to the inlet and outlet directions of the regulating valve. 3. Adjustment range: Set the adjustment range of the regulating valve according to actual needs, generally between 20% and 80%.
4. Adjustment method: Manual adjustment is suitable for small equipment, while automatic adjustment is suitable for large equipment.
5. Calibration: Regulating valves typically require calibration to ensure accurate signal response and achieve precise flow, pressure, or temperature regulation.
The calibration process includes setting the valve core position and stroke range, adjusting the valve core sensitivity, calibrating the valve core feedback signal, and setting the parameters of the PID controller. two
6. Operating procedures: Ensure that the power and control signals of the regulating valve are connected correctly, start the control system, and check whether the valve core is normal
Exercise, monitor changes in fluid flow rate, pressure, or temperature, and adjust valve core position as needed. Regularly inspect and maintain the regulating valve, including cleaning the valve body and valve core, checking if the seals are intact, and ensuring good electrical connections.
7. Parameter setting: In Burkert regulating valves, certain parameters need to be set, such as setting pressure range and flow range
Surrounding, setting control mode and setting output signal 3
8. Debugging and optimization: After completing the initial setup, perform manual testing and automatic mode testing to ensure that the regulating valve can
Realize automatic control as expected. If the performance is not ideal, you can further optimize the parameter settings.
9. Maintenance and upkeep: Regularly inspect the connection of the regulating valve, clean the valve and sensor to ensure their normal operation and longevity
Fate.
Our company's standard model:
ASCO solenoid valve \ \ HB8320G176 \ \ 1/4 '\ \ AC220V \ \ 0-1MPA\\
ASCOSCHTXB223A127T TPL:06097 230/50
ASCO8210G027R 110/50
ASCONF8316A084VCG 220/50
ASCO614359G001150
ASCOSC8210D014 110/50
ASCO608260111
ASCOSCG353G047 24VDC
ASCOE290A393VI
ASCOJ34BB452CG60S40\\1/4NPT\\AC220V
ASCOYA2BA4522G00040
ASCO52100001 DC24V
ASCONFG551B401MO 24VDC
ASCOSCG531C001MS 24VDC
ASCOVCEFCM8551G401MO,24VDC
ASCOSCE238D004, 230/50
ASCOSCG531C001MS DC24V
ASCOSCG551A018MS 24VDC