Awareness enzyme-linked immunosorbent assay (ELISA) detection strip/reagent strip from the United States

NegotiableUpdate on 01/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The $r $nDri Dye Check Strips 450, produced by Awareness Technology, Inc., is a detection strip used to validate the performance of microplate and microplate readers
Product Details

Awareness enzyme-linked immunosorbent assay (ELISA) detection strip/reagent strip from the United States

Dri Dye Check Strips 450 is a testing strip produced by Awareness Technology, Inc., used to verify the performance of microplate and microplate readers.

1、 Product composition

Awareness enzyme-linked immunosorbent assay (ELISA) detection strip/reagent strip from the United StatesIt contains 6 test strips, 1 strip tray, chart record table, and acceptance standard instructions, and is stored at room temperature.

2、 Purpose:

Used to verify the calibration, precision, and linearity of enzyme-linked immunosorbent assay (ELISA) analyzers, microplate and microplate readers.

3、 Usage method

1. Preparation: Prepare 200 microliters of deionized water.

2. Hydration detection strip: Add 200 microliters of deionized water into the hole of the detection strip, and use the product's ability to automatically correct the inaccuracy when adding water to complete hydration.

3. Reading: Use a reading instrument with dual color reading function and the ability to read in the 1-12 and A-H directions to read the detection strip data at a wavelength of 450nm (this product also supports 405nm and 492nm wavelengths).

4. Result comparison: Compare the read results with the pre-set acceptance criteria to determine whether the calibration, linearity, and repeatability of the reading instrument meet the requirements.

4、 Precautions

-Storage: Please store the product at room temperature to ensure a longer shelf life.

-Operation specification: Use deionized water for hydration operation to ensure the accuracy of the test results.

-Adhere to standards: Strictly evaluate the performance of the reading instrument according to predetermined acceptance criteria.