For applications that require a measurement range of 1.7 μ m in near-infrared, Avantes offers a new non cooled spectrometer AvaSpec-NIR256/512-1.7-EVO, which uses a high-sensitivity optical platform and circuit board. Both spectrometers have excellent performance parameters, such as a sampling speed of up to 0.53 ms and integration time as short as 10 or 20 μ s. For applications that require high resolution or require more data points for modeling, a 512 pixel detector will be your better choice.
The AvaSpec-NIR256/512-1.7-EVO spectrometer will continue to use InGaAs array detection and ultra-low noise circuit boards with USB3 and Gigabit Ethernet interfaces. The digital and analog I/O interfaces of the spectrometer can achieve external triggering of the spectrometer and control of the pulse light source and shutter, and two different gain modes can be selected through software, namely high sensitivity mode (HS, default) and low noise (LN) mode. This economical non cooled spectrometer is powered by USB and comes with four types of gratings to choose from, with replaceable slits to meet your application needs.

| Spectrometer model | AvaSpec-NIR256-1.7-EVO | AvaSpec-NIR512-1.7-EVO |
| Optical platform | Symmetric Czerny Turner optical path, 50mm focal length | |
| Wavelength Range | 900 - 1750 nm | |
| resolving power | 2.0 - 50 nm | |
| Stray light | <1% | |
| Sensitivity count value (HS)/μW per ms integration time | 8,200,000 (integral 1000-1750 nm) | 3,800,000 (integral 1000-1750 nm) |
| Signal to Noise Ratio (HS) | 1900:1 | |
| Integral Time (HS) | 10 μs - 500 ms | |
| Sensitivity count value (LN) /μW per ms integration time | 469,000 (integral 1000-1750 nm) | 222,000 (integral 1000-1750 nm) |
| Signal to Noise Ratio (LN) | 5000:1 | |
| Integral time (LN) | 10 μs - 10 seconds | |
| detector | InGaAs linear array, 256 pixels, 50 μ m × 500 μ m | InGaAs linear array, 512 pixels, 25 μ m × 500 μ m |
| AD converter | 16 bit, 500kHz | |
| Interface | USB 3.0 high-speed, 5 Gbps, Gigabit Ethernet 1 Gbps | |
| Sampling speed | 0.53 ms/scan | |
| Data transmission speed |
0.53 ms/scan (USB3) |
|
| Digital IO interface | HD-26 connector, 2 analog inputs, 2 analog outputs, 3 digital inputs, 13 digital outputs, bidirectional, trigger, synchronous, strobe, laser | |
| Power Supply | Default USB power supply, 600 mA or external 12VDC, 320 mA (4W) | |
| Dimensions and weight | 185 x 84 x 185 mm, 2.7 Kg |
|
| Available Range | Spectral range (nm) | Line pairs/mm | Sparkling wavelength (nm) | Grating model | |
| NIR | 900-1750 | 850 | 200 | 1500 | NIR200-1.5 |
| NIR | 1000-1700 | 340 | 400 | 1600 | NIR400-1.6 |
NIR |
900-1400 |
200 | 600 |
1200 |
NIR600-1.2 |
| NIR | 1300-1600 | 170 | 600 | 1600 | NIR600-1.6 |
| Slit width (μ m) | |||||
| Logarithms of grating lines (lines/mm) | 25* | 50 | 100 | 200 | 500 |
| 200 | 6 | 8 | 12 | 22 | 50 |
| 400 | 2.5 | 3 | 6 | 12 | 25 |
| 600 | n.a. | 2 | 4 | 8 |
18 |
*Only applicable to AvaSpec-NIR512
| AvaSpec-NIR256-1.7- EVO | 50mm AvaBench, 256 pixel InGaAs detector, high-speed USB3 fiber spectrometer, 50mm AvaBench, 256 pixel InGaAs detector, high-speed USB3 and ETH interfaces, with replaceable slits, including AvaSoft Basic, USB interface cable, OSF-850 / 1000-3。 Specify grating, wavelength range, and slit. |
| AvaSpec-NIR512-1.7-EVO |
50mm AvaBench, 512 pixel InGaAs detector, high-speed USB3 fiber spectrometer, 50mm AvaBench, 512 pixel InGaAs detector, high-speed USB3 and ETH interfaces, with replaceable slits, including AvaSoft Basic, USB interface cable, OSF-850 / 1000-3。 Specify grating, wavelength range, and slit. |