AvaSpec-NIR256/512-1.7-EVO Uncooled Near Infrared Fiber Spectrometer

NegotiableUpdate on 04/03
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
For applications that require a measurement range of 1.7 μ m in near-infrared, Avantes offers a new non cooled spectrometer AvaSpec-NIR256/512-1.7-EVO, which uses a high-sensitivity optical platform and circuit board. Both spectrometers have excellent performance parameters, such as a sampling speed of up to 0.53 ms and integration time as short as 10 or 20 μ s. For applications that require high resolution or require more data points for modeling, a 512 pixel detector will be your better choice.
Product Details
AvaSpec-NIR256/512-1.7-EVO Uncooled Near Infrared Fiber Spectrometer

For applications that require a measurement range of 1.7 μ m in near-infrared, Avantes offers a new non cooled spectrometer AvaSpec-NIR256/512-1.7-EVO, which uses a high-sensitivity optical platform and circuit board. Both spectrometers have excellent performance parameters, such as a sampling speed of up to 0.53 ms and integration time as short as 10 or 20 μ s. For applications that require high resolution or require more data points for modeling, a 512 pixel detector will be your better choice.

The AvaSpec-NIR256/512-1.7-EVO spectrometer will continue to use InGaAs array detection and ultra-low noise circuit boards with USB3 and Gigabit Ethernet interfaces. The digital and analog I/O interfaces of the spectrometer can achieve external triggering of the spectrometer and control of the pulse light source and shutter, and two different gain modes can be selected through software, namely high sensitivity mode (HS, default) and low noise (LN) mode. This economical non cooled spectrometer is powered by USB and comes with four types of gratings to choose from, with replaceable slits to meet your application needs.

technical data
Spectrometer model AvaSpec-NIR256-1.7-EVO AvaSpec-NIR512-1.7-EVO
Optical platform Symmetric Czerny Turner optical path, 50mm focal length
Wavelength Range 900 - 1750 nm
resolving power 2.0 - 50 nm
Stray light <1%
Sensitivity count value (HS)/μW per ms integration time 8,200,000 (integral 1000-1750 nm) 3,800,000 (integral 1000-1750 nm)
Signal to Noise Ratio (HS) 1900:1
Integral Time (HS) 10 μs - 500 ms
Sensitivity count value (LN) /μW per ms integration time 469,000 (integral 1000-1750 nm) 222,000 (integral 1000-1750 nm)
Signal to Noise Ratio (LN) 5000:1
Integral time (LN) 10 μs - 10 seconds
detector InGaAs linear array, 256 pixels, 50 μ m × 500 μ m InGaAs linear array, 512 pixels, 25 μ m × 500 μ m
AD converter 16 bit, 500kHz
Interface USB 3.0 high-speed, 5 Gbps, Gigabit Ethernet 1 Gbps
Sampling speed 0.53 ms/scan
Data transmission speed

0.53 ms/scan (USB3)

Digital IO interface HD-26 connector, 2 analog inputs, 2 analog outputs, 3 digital inputs, 13 digital outputs, bidirectional, trigger, synchronous, strobe, laser
Power Supply Default USB power supply, 600 mA or external 12VDC, 320 mA (4W)
Dimensions and weight 185 x 84 x 185 mm, 2.7 Kg


Grating selection table
Available Range Spectral range (nm) Line pairs/mm Sparkling wavelength (nm) Grating model
NIR 900-1750 850 200 1500 NIR200-1.5
NIR 1000-1700 340 400 1600 NIR400-1.6

NIR

900-1400

200

600

1200

NIR600-1.2

NIR 1300-1600 170 600 1600 NIR600-1.6


Resolution Table of Spectrometer
Slit width (μ m)
Logarithms of grating lines (lines/mm) 25* 50 100 200 500
200 6 8 12 22 50
400 2.5 3 6 12 25
600 n.a. 2 4 8

18

*Only applicable to AvaSpec-NIR512

ordering information
AvaSpec-NIR256-1.7- EVO 50mm AvaBench, 256 pixel InGaAs detector, high-speed USB3 fiber spectrometer, 50mm AvaBench, 256 pixel InGaAs detector, high-speed USB3 and ETH interfaces, with replaceable slits, including AvaSoft Basic, USB interface cable, OSF-850 / 1000-3。 Specify grating, wavelength range, and slit.
AvaSpec-NIR512-1.7-EVO

50mm AvaBench, 512 pixel InGaAs detector, high-speed USB3 fiber spectrometer, 50mm AvaBench, 512 pixel InGaAs detector, high-speed USB3 and ETH interfaces, with replaceable slits, including AvaSoft Basic, USB interface cable, OSF-850 / 1000-3。 Specify grating, wavelength range, and slit.

PS-12V/1.0 The external power required to run in ETH mode.