Konica MinoltaAutomatic scanning spectrophotometerFD-9 is good, not only can it measure standard color charts at high speed, but it can also bring higher precision and efficiency workflow in color management for printing industry users.
In order to improve production efficiency and product quality in the printing field, the focus of color management work is gradually shifting towards pursuing automation. For example, in the workflow of measuring and controlling colors digitally, it is necessary to minimize manual labor while ensuring speed and accuracy. In order to meet these demands, Konica Minolta has launched for the fields of graphic art and printingAutomatic scanning spectrophotometerFD-9。
FD-9 has multiple advantages: (1) it implements high-speed single point measurement, which not only has faster measurement speed but also ensures measurement accuracy; (2) the selected automatic paper feeder can perform continuous measurement, which can improve work efficiency and reduce manual labor. (3) The free chart formatting feature allows you to continue using charts in their original format, and even measure mixed charts directly without the need to reformat the chart.
Processing a chart with 1500 color blocks takes approximately 4 minutes from inserting the color chart to outputting measurement data. In addition, the FD series can obtain results through a single measurement under various standard measurement conditions (M0, M1, and M2), so only one scan of the color chart is required.
To ensure accuracy, the instrument scans at a series of ultra high speeds: it accurately locates the FD-9 color sensor at each measurement point, then stops the scanning action, measures that point, and after completion, moves to the next measurement point.



The automatic color block detection function allows printed materials that mix color blocks with images or illustrations (such as example chart 2) to be measured without the need for a pre-set chart definition file, so existing charts can continue to be used. At the beginning of each measurement, FD-9 pre scans the chart through an image sensor, automatically detects measurement points, and then scans and measures the detected color blocks. The automatic detection function of color blocks also means that the markers used by traditional colorimeters to detect the position of color blocks are no longer needed.
In addition, a grid measurement can be used to measure a chart where the entire page is filled with color blocks, such as example chart 1, to distinguish which printed areas have uneven colors.

Example Chart 1

Example Chart 2

The selected automatic paper feeder can simultaneously load up to 100 charts into the feeder and perform continuous measurements. Because there is no need to frequently place charts, the instrument can also perform color measurements at night, which can improve work efficiency and reduce manual labor.

The LCD display screen enhances user operability and displays the working status of FD-9.

The LAN connection function enables multiple computers or other devices to share one FD-9.

Used for inspection of BCRA standard 14 color palette (customized)
The color palette allows users to easily check whether the measured values of FD-9 are correct.
Konica Minolta has a vast service support network, including service centers located in the United States, Europe, and Asia, as well as factories in Japan. No matter where you are, we can provide fast service and calibration support for FD-9.
| Lighting/Receiving System | 45 ° A: 0 ° (circular illumination) * 1 |
|---|---|
| Complies with CIE No. 15, ISO 7724/1, DIN5033 Teil 7, ASTM E 1164, and JIS Z 8722 reflectance measurement conditions. | |
| Spectral method | Concave grating |
| wavelength range | 380 ~ 730 nm |
| Wavelength interval | 10 nm |
| Half wave width | About 10 nm |
| measurement caliber | About 3 mm |
| light source | LED |
| measurement range | Reflectivity: 0 to 150% |
| repetitiveness | Chromaticity: within 0.05 σ? E00 (without polarized light filter installed) |
| *After the whiteboard calibration is performed, measure the white calibration board 30 times at 1-second intervals under Konica Minolta testing conditions | |
| Inter device difference | E00 within 0.3 (average value of BCRA II series 12 color plate, compared to the measured value under Konica Minolta standard conditions [without polarizing filter installed]) |
| measure time | About 4 minutes for every 1500 color blocks *Konica Minolta measurement conditions * 3 |
| output data | Spectral reflectance |
| Measurement conditions * 2 | M0 (A)、M1 (D50)、M2(A + UV 截断)、 C、ID50、D65、ID65、 F2、F6、F7、F8、F9、F10、F11、F12、 User defined light source |
| Substrate conditions | White substrate, compliant with ISO13655 |
| interface | USB2.0、10Base-T/100Base-TX |
| power supply | AC power adapter (input: AC 100 to 240 V, 50/60 Hz; Output: DC 24 V, 5 A) |
| size | Only applicable to FD-9: Width 716 x Depth 251 x Height 159mm Automatic paper feeder: Width 601 x Depth 1158 (When the cardboard box is opened) x height 245mm |
| weight | Only applicable to FD-9: approximately 10.5 kilograms |
| Operating temperature/humidity range | Temperature 10 to 35 ° C, relative humidity 30 to 85% (no condensation) |
| Storage temperature/humidity range | Temperature 0 to 45 ° C, relative humidity 0 to 85% (no condensation) |
| Standard Accessories | AC power adapter, USB data cable, measuring tool software FD-S2w |
| Optional accessories | Automatic paper feeder FD-A09 |
| width | 45 to 330 millimeters |
|---|---|
| length | 170 to 660 millimeters |
| thickness | 0.05 to 0.45 millimeters |
| Minimum color block size | 6 x 6 millimeters |
| The maximum number of color blocks per sheet of paper | 1394 (A4) 2928 (A3) |
| Operating environment | operating system | Windows7/Windows8.1/ Windows10 MacOS X 10.9-10.10 |
|---|---|---|
| CPU | 1 GHz or above processor | |
| memory | 1GB or above (32-bit)/ 2GB or above (64 bit) | |
| hard disk | The available hard disk space should not be less than 8 GB | |
| monitor | The display resolution should be at least 1024 x 768 | |
| interface | USB 2.0、10Base-T/100Base-TX | |
| Compatible instruments | FD-9 FD-7/CL-500A (Read function only applicable to user-defined light sources) | |
| feature | Chart creation, chart measurement, measurement data display, measurement file output, QR code creation | |
| Displayed measurement data | Spectral reflectance, chromaticity value, density value | |
| Measurement conditions * 2 | M0 (A)、M1 (D50)、M2(A + UV 截断)、 C、ID50、D65、ID65、F2、F6、F7、F8、F9、F10、F11、F12 User defined light source | |
| lighting | A、C、D50、ID50、D65、ID65、F2、F6、F7、F8、 F9, F10, F11, F12, A+UV truncation, user-defined light source | |
| Standard Observer | 2 ° or 10 ° standard observer | |
| color gamut | L*a*b*、L*C*h、XYZ | |
| PC supports languages | English, French, German, Spanish, Japanese, Chinese (Simplified) | |
| output format | CxF3:ISO17972-1:2015 CGATS:ISO28178:2009 (ANSI CGATS-17) FD-S2w original format (csv/tsv) | |