APC-E seriesAtmospheric pre concentratorIt can be used in conjunction with any commercially available gas chromatography GC or gas chromatography-mass spectrometry (GCMS) to analyze trace volatile organic compounds (VOCs) in the atmosphere through a two-stage cold trap.
Applicable Standards | APPLICABLE STANDARDS
GB/T14678-1993 Air quality - Determination of hydrogen sulfide, methyl mercaptan, methyl sulfide and dimethyl disulfide - Gas chromatographic method
HJ 759-2023 Determination of 65 volatile organic compounds in ambient air - Can sampling/gas chromatography-mass spectrometry method
DB37/T 4434-2021 Determination of 57 Ozone Precursors in Environmental Air by Tank Sampling Gas Chromatography Hydrogen Flame Ionization Detector Mass Spectrometry
HJ 1078-2019 Determination of 8 sulfur-containing organic compounds, including methyl mercaptan, in waste gas from fixed sources - Gas bag sampling pre concentration/gas chromatography-mass spectrometry method
Appendix B, Appendix C, and Appendix D of the Technical Requirements for Manual Monitoring of Ozone Precursors in Environmental Air
APC-E seriesAtmospheric pre concentratorProduct Features | Product Features
Electronic refrigeration -45 ℃, no need for liquid nitrogen cooling, low cost, convenient to use.
Air bag or Suma can injection, can be equipped with two sets of 12 position automatic samplers at the same time.
Fully inert pipeline, heated and temperature controlled throughout the entire area, with no cold spots or adsorption, and lower residue, supporting automatic quantitative addition of two internal standard gases.
Secondary cold trap effectively removes interfering components such as H2O, O2, CO2 from the sample.
7-inch high-definition touch screen control, real-time display of dynamic flow path, easy to operate and learn.
Wide concentration volume, ranging from 0.1ml to 2000ml, with electronic flow control for concentration flow rate and time, making high and low concentration testing more convenient.
The electronic record traceability function can store the last 56 sample testing process parameters.
The same sample can be extracted multiple times, up to a maximum of 99 times.
| 1 Su code can automatic sampler
One or two 12 bit 1-6L Su code tank automatic samplers can be configured. Multiple injection function: The same Su code control can achieve up to 9 repeated concentrated injections, effectively improving parallel detection capability. Equipped with channel reverse cleaning function, it can eliminate residual pollution from the previous cycle. Multiple switching valves and transmission pipelines have heating functions, eliminating sample retention.
|
|
|
| 2 tank cleaning equipment Equipped with heating function, temperature range: room temperature -120 degrees, temperature control accuracy:+1 ° C, equipped with high flow vacuum pump, pumping rate per minute: 3000ml/min.
|
| 3 Dynamic Dilution Meter The built-in microprocessor independently controls the operation and can automatically complete various standard gas and sample dilutions. Dilution ratio: 1-1000 times, maximum dilution ratio of 2500 times.
|
|
They are all using Taitong (some companies)


Resolve your backup advantages


Provide technical support for installation, debugging, and training
Taitong technical engineers can provide on-site technical guidance and communication. After on-site communication, installation, debugging, and on-site acceptance testing can be carried out within 2 hours. Installation, debugging and acceptance completed, on-site
Provide a solution. Training on usage and operation, after passing the acceptance inspection and being put into operation, regularly organize relevant personnel for training.
Ensure scientific management of delivery time and traceability of production progress

quality control
Incoming inspection and control, each finished product is tested and inspected to be qualified before leaving the factory
Layer by layer inspection, the finished product must pass 52 tests and pass the inspection before leaving the factory

Factory live shooting
Legitimate manufacturers provide greater assurance

CNC machining center
High quality supervision, product development and upgrading capabilities, and customizable activation devices with different functions

Service Process

Quickly understand Taitong thermal analysis and find solutions suitable for the industry