Welcome Customer !

Membership

Help

Guangzhou Xijiang Instrument Equipment Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Guangzhou Xijiang Instrument Equipment Co., Ltd

  • E-mail

  • Phone

  • Address

    2A04, Building B2, Yunsheng Science Park, No. 11 Spectral Middle Road, Huangpu District, Guangzhou City, Guangdong Province

Contact Now

Atmospheric pre concentrator

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The APC-E series atmospheric pre concentration instrument can be connected to any commercially available gas chromatography GC or gas chromatography-mass spectrometry (GCMS) instrument for the analysis of trace volatile organic compounds (VOCs) in the atmosphere through a secondary cold trap.

Product Details

APC-E seriesAtmospheric pre concentratorIt can be used in conjunction with any commercially available gas chromatography GC or gas chromatography-mass spectrometry (GCMS) to analyze trace volatile organic compounds (VOCs) in the atmosphere through a two-stage cold trap.

Applicable Standards | APPLICABLE STANDARDS

GB/T14678-1993 Air quality - Determination of hydrogen sulfide, methyl mercaptan, methyl sulfide and dimethyl disulfide - Gas chromatographic method

HJ 759-2023 Determination of 65 volatile organic compounds in ambient air - Can sampling/gas chromatography-mass spectrometry method

DB37/T 4434-2021 Determination of 57 Ozone Precursors in Environmental Air by Tank Sampling Gas Chromatography Hydrogen Flame Ionization Detector Mass Spectrometry

HJ 1078-2019 Determination of 8 sulfur-containing organic compounds, including methyl mercaptan, in waste gas from fixed sources - Gas bag sampling pre concentration/gas chromatography-mass spectrometry method

Appendix B, Appendix C, and Appendix D of the Technical Requirements for Manual Monitoring of Ozone Precursors in Environmental Air

APC-E seriesAtmospheric pre concentratorProduct Features | Product Features

Electronic refrigeration -45 ℃, no need for liquid nitrogen cooling, low cost, convenient to use.

Air bag or Suma can injection, can be equipped with two sets of 12 position automatic samplers at the same time.

Fully inert pipeline, heated and temperature controlled throughout the entire area, with no cold spots or adsorption, and lower residue, supporting automatic quantitative addition of two internal standard gases.

Secondary cold trap effectively removes interfering components such as H2O, O2, CO2 from the sample.

7-inch high-definition touch screen control, real-time display of dynamic flow path, easy to operate and learn.

Wide concentration volume, ranging from 0.1ml to 2000ml, with electronic flow control for concentration flow rate and time, making high and low concentration testing more convenient.

The electronic record traceability function can store the last 56 sample testing process parameters.

The same sample can be extracted multiple times, up to a maximum of 99 times.

1 Su code can automatic sampler

One or two 12 bit 1-6L Su code tank automatic samplers can be configured.

Multiple injection function: The same Su code control can achieve up to 9 repeated concentrated injections, effectively improving parallel detection capability.

Equipped with channel reverse cleaning function, it can eliminate residual pollution from the previous cycle.

Multiple switching valves and transmission pipelines have heating functions, eliminating sample retention.

苏码罐自动进样器(2).png

WPS图片(1).png

2 tank cleaning equipment

Equipped with heating function, temperature range: room temperature -120 degrees, temperature control accuracy:+1 ° C, equipped with high flow vacuum pump, pumping rate per minute: 3000ml/min.

3 Dynamic Dilution Meter

The built-in microprocessor independently controls the operation and can automatically complete various standard gas and sample dilutions.

Dilution ratio: 1-1000 times, maximum dilution ratio of 2500 times.

1.jpg

They are all using Taitong (some companies)

image.png

image.png

Resolve your backup advantages

image.png

image.png

Provide technical support for installation, debugging, and training

Taitong technical engineers can provide on-site technical guidance and communication. After on-site communication, installation, debugging, and on-site acceptance testing can be carried out within 2 hours. Installation, debugging and acceptance completed, on-site

Provide a solution. Training on usage and operation, after passing the acceptance inspection and being put into operation, regularly organize relevant personnel for training.

Ensure scientific management of delivery time and traceability of production progress

image.png

quality control

Incoming inspection and control, each finished product is tested and inspected to be qualified before leaving the factory

Layer by layer inspection, the finished product must pass 52 tests and pass the inspection before leaving the factory

image.png

Factory live shooting

Legitimate manufacturers provide greater assurance

image.png

CNC machining center

High quality supervision, product development and upgrading capabilities, and customizable activation devices with different functions

image.png

Service Process

image.png

Quickly understand Taitong thermal analysis and find solutions suitable for the industry

image.png