E-mail
chinaweisi@chinaweisi.com
-
Phone
18622500837
-
Address
No.1 Xixiaozhuang Industrial Zone, Chagugang Town, Wuqing District, Tianjin City
Tianjin Weisi Experimental Instrument Technology Co., Ltd
chinaweisi@chinaweisi.com
18622500837
No.1 Xixiaozhuang Industrial Zone, Chagugang Town, Wuqing District, Tianjin City
1. Ci4400/Ci4000 with Right Light/Quartz filter system for 4000 hours
Description: Factory original sealed xenon lamp for Ci4000 and Ci4400, equipped with Right Light inner filter and Quartz outer filter (daylight I)

Type). The consumables package is recommended to be replaced after 4000 hours (including 2 sets of sealed xenon lamps).
2. Ci4400/Ci4000 4000 4000 hour sealed xenon lamp with BoroS/BoroS filter system

Description: Factory original sealed xenon lamp for Ci4000 and Ci4400, equipped with Boro/Boro filter system (Nikko II)
Type). The consumables package is recommended to be replaced after 4000 hours (including 2 sets of sealed xenon lamps).

3. O-ring housing for Ci6 */3 * deionization filter cartridge
Description: O-ring housing for Ci6 */3 * and Ci65/35 deionization filter cartridges.

4. Gaskets and filters (60 x 50, SS 0.82 "diameter) for Ci6 */3 * water flow switches and vibrating water pipes
Description: Gasket and filter (60 x 50, SS 0.82 "diameter), used for Ci6 */3 * and Ci65/35 water flow switches and vibrating water pipes.

5. Air filter for Ci6 */3 * LiquiAir system
Description: Air filter for Ci6 */3 * and Ci65/35 LiquiAir systems.

6. AATCC L2 Blue Wool
Description: AATCC L2 blue wool standard sample.

7. Polystyrene weathering aging standard sample (50 pieces set)
Description: Polystyrene weathering aging standard sample (sold in packs of 50 pieces).

8. Xenon lamp tube clamp for Ci4400/Ci4000/Ci6 */3 *

Description: Used for xenon lamp tube clamps for Ci4400, Ci4000, Ci6 */3 *, and Ci65/35.
9. Sealing gasket for Ci4400/Ci4000/Ci6 */3 * 6.5 kW xenon lamp tube

Description: 6.5kW xenon lamp tube sealing gasket for Ci4400, Ci4000, Ci6 */3 *, and Ci65/35.
10. Ci4400/Ci4000/Ci6 */3 * 6.5kW xenon lamp tube water seal rubber ring

Description: 6.5kW xenon lamp tube sealing gasket for Ci4400, Ci4000, Ci6 */3 *, and Ci65/35.
11. 2000h sealed Ci4400/Ci4000 with Right Light/Quartz filter system

Description: Factory original sealed xenon lamp for Ci4000 and Ci4400, equipped with Right Light inner filter and Quartz outer filter (daylight type I).
Suggest replacing it after 2000 hours.

12. Ci4400/Ci4000 2000h sealed xenon lamp with BoroS/BoroS filter system
Description: Factory original sealed xenon lamp for Ci4000 and Ci4400, equipped with Boro/Boro filter system (daylight type II). Suggest in

Replace after 2000 hours.
13. Blue wool ISO types 1-8 for Xenotest 220/220+/440

Description: Blue wool ISO types 1-8 for Xenotest 220/220+/440

14. XENOSENSIV RC 340/420 BPT-C adapter kit for Xenotest sample holder
15. Light monitor for Xenotest 220/220+/440; Control Blackboard Temperature (BPT) and 420nm

Description: Calibration XENOSENSIV RC 340 BPT-C optical monitor using radio control technology. Installed in the instrument to control irradiance at 340 nm and blackboard temperature
(BPT)。

16. Xenotest 220+/440 photodetector; Used to control blackboard temperature (BPT) and irradiation at 340 nm
Description: Calibration XENOSENSIV RC 340 BPT-C optical monitor using radio control technology. Installed in the instrument to control irradiance at 340 nm and blackboard temperature

(BPT)。
17. AATCC L2 Blue Wool

Description: AATCC L2 blue wool standard sample.
18. Polystyrene weathering aging standard sample (50 pieces set)

Description: Polystyrene weathering aging standard sample (sold in packs of 50 pieces).
Xenotest Alpha LM Xenon Lamp Tube XE2000

Description: The 1700 watt xenon lamp tube XE2000 is used for Xenotest Alpha LM and is recommended to be replaced every 1500 hours.
Xenotest 150S Xenon Lamp Tube XE1501

Description: The 2200 watt xenon lamp tube XE1501 is used for the Xenotest 150S and is recommended to be replaced every 1500 hours.
21. External quartz for Xenotest 220+/440/Beta+series

Description: Used for Xenotest 220+/440/Beta+series outer tube quartz. It is recommended to replace it every 25000 hours. Right Light with filtering system
Used in combination with code 56080338.

22. Xenotest 220+/440 Right Light Filter
Description: Xenotest 220+/440 Right Light filter system, according to ASTM

D7869 simulates sunlight using spectral intensity. Suggest replacing every 25000 hours. Used in combination with "outer tube quartz", 56052875.
Xenochrome 320 filter glass from Xenotest Alpha series

Description: Xenochrome 320 filter glass is used for Xenotest Alpha+and Xenotest Alpha
HE, Simulate sunlight behind the window glass. Suggest replacing every 25000 hours.

Xenochrome 300 filter glass from Xenotest Alpha series
Description: Xenochrome 300 filter glass is used for Xenotest Alpha+and Xenotest Alpha

HE, Simulate sunlight. Suggest replacing every 25000 hours.
25. Alpha series TM16 infrared absorption filter system

Description: Xenotest Alpha series absorption filter system, including 7 filters and lantern covers. Simulate AATCC
Sunlight behind the TM16 window glass. It is recommended to replace it every 4000 hours.

The Alpha series is equipped with a filtering system with 10 window glass filters
Description: Window glass absorption filter system for Xenotest Alpha+and Xenotest Alpha
HE. Simulate sunlight behind the window glass for interior polymer testing. It is recommended to replace it every 4000 hours.
Xenotest 150S/S+/Alpha series filtration system with 7 infrared absorption filters

Description: A filtering system equipped with 7 infrared absorption filters is used for the Xenotest 150S/S+/Alpha series. Simulate sunlight behind the window glass. It is recommended to replace it every 3500 hours.
Xenotest Alpha series window glass filters

Description: Window glass filter for Xenotest Alpha+and Xenotest Alpha
The HE series comes with a lantern cover with 10 window glass filters. Simulate sunlight behind the window glass. It is recommended to replace it every 4000 hours.

Xenochrome 320 filter system for Xenotest Alpha series
Description: The filter system is used for Xenotest Alpha+and Xenotest Alpha HE to simulate sunlight behind window glass. Suggest replacing every 25000 hours.

Xenochrome 300 filter system for Xenotest Alpha series
Description: The filter system is used for Xenotest Alpha+and Xenotest Alpha HE to simulate sunlight. Suggest replacing every 25000 hours.

31. Xenotest 150S/S+/Alpha series infrared filter glass
Description: Infrared filter glass is used for Xenotest 150S and Xenotest 150S+, Xenotest Alpha+, and Xenotest Alpha
.
LM and Xenotest Alpha HE. It is recommended to replace it every 3500 hours.
32. Xenotest 150 S+/Alpha series Suprax external filter sleeve

Description: Suprax external filter sleeve is used for Xenotest 150 S+, Xenotest Alpha+, and Xenotest Alpha
E. Suggest replacing every 25000 hours.

33. Xenotest 150 S+/Alpha series UV black glass for infrared absorption filter systems
Description: UV black glass is used for Xenotest 150 S+, Xenotest Alpha+, Xenotest Alpha LM, and Xenotest

Alpha HE's infrared absorption filter system. Suggest replacing every 15000 hours.
Xenotest 150 S+/Alpha series 2200 watt U-shaped xenon lamp tube

Description: 2200 watt xenon lamp tube for Xenotest 150 S+, Xenotest Alpha+, and Xenotest Alpha
HE, U-shaped, it is recommended to replace it every 1500 hours.

35. Xenotest Beta+FD Store Lighting External Filter Sleeve
Description: Xenotest Beta+FD's store lighting external filter sleeve is used to simulate typical lighting conditions inside retail stores. Suggest replacing every 25000 hours.

Xenochrome 320 filter system for Xenotest Beta+and Beta+FD
Description: The Xenochrome 320 filter system is used in the Xenotest Beta series to simulate sunlight behind window glass. Suggest replacing every 25000 hours.

Xenochrome 300 filter system for Xenotest Beta+and Beta+FD
Description: The Xenochrome 300 filter system is used in the Xenotest Beta series to simulate sunlight. Suggest replacing every 25000 hours.

38. Xenotest Beta Series 2200W Xenon Lamp Tube
Description: Xenotest Beta series 2200 watt xenon lamp tubes are recommended to be replaced every 1500 hours.

39. Xenotest Beta series set of 3 2200 watt xenon lamp tubes
Description: Xenotest Beta series 2200 watt xenon lamp tube set (3 pieces), recommended to be replaced every 1500 hours.

40. Xenotest 220/220+set of 3 2200 watt xenon lamp tubes
Description: Xenotest 220/220+2200 watt xenon lamp tube set (3 pieces), recommended to be replaced every 1500 hours.

41. Xenotest 220/220+2200 watt xenon lamp tube
Description: Xenotest 220/220+2200 watt xenon lamp tube, recommended to be replaced every 1500 hours.

Xenotest 220/220+Window Glass Filter System for AATCC TM16
Description: Xenotest 220/220+filter system, including filter lantern cover and 6 filters, simulating AATCC

Sunlight behind the TM16 window glass. Suggest replacing every 25000 hours.
43. Xenochrome 320 Extended Infrared Filter System for High Temperature Lightfastness Testing of Xenotest 440

Description: Xenochrome 320 Extended Infrared Filter System for Xenotest 440, including filter lantern cover and 11
A filter. Simulate sunlight behind the window glass for high-temperature light fastness testing. Suggest replacing every 25000 hours.

44. Xenotest 440 for AATCC TM16 Window Glass Filter System

Description: Xenotest 440 window glass filter system, including filter lantern cover and 8 filters, simulating AATCC