Disinfection robots are based on robots, and a disinfection system is installed inside the robot to generate disinfection gas. The pneumatic system of the robot is used to quickly spread the disinfection gas in the indoor space, increasing the coverage and uniformity of disinfection. It can effectively kill pathogenic microorganisms in the air. Usually, ozone, hydrogen peroxide, or ethylene oxide gas are sampled to disinfect the environment. Next, taking ozone as an example, we will talk about how to choose an ozone concentration gas detector for disinfection robots to detect ozone concentration in the environment?
Application of Ozone Gas Detector in Disinfection RobotsOzone has a major drawback in the disinfection process, which is that the concentration of ozone is difficult to control. If the concentration of ozone is too high, it can cause harm to the human body. If the concentration is too low, the disinfection and sterilization effect will also be affected, so when using it, the concentration of ozone must be set within a safe range. Because when using ozone disinfection, it takes about 30 minutes to decompose oxygen So after sterilization is completed, you cannot enter the disinfection site immediately. You need to wait for 30 minutes before entering, so as not to cause harm to the human body. So at this time, the Shenzhen Guoan fixed ozone concentration gas detector can be used. The detector is fixed in the environment for 24 hours to detect ozone concentration. The Shenzhen Guoan fixed ozone concentration gas detector also comes with two sets of relays, which can be linked to fans and valves to ventilate and reduce concentration as soon as possible after disinfection.
Application of Ozone Gas Detector in Disinfection RobotsWhen residual ozone levels need to be detected during the disinfection process, the online detector on site is lowered to a concentration range that our personnel can safely enter. The staff can then carry our portable ozone concentration detector from Shenzhen Guoan to monitor the concentration on site. It is recommended to choose a concentration range of 0-1PPM to achieve the air quality level. The portable ozone concentration detector adopts a pump suction sampling method, which is more convenient and fast. It can store 100000 pieces of data and record on-site data in real time