Anwochi AVEENTICS solenoid valve/pneumatic valve first level distributor - Shanghai Nianci Machinery Equipment Co., Ltd. - We are dedicated to serving you. AVEENTICS solenoid valves have sealed chambers with through holes at different positions, each hole connected to a different oil pipe. The middle of the chamber is a piston, and there are two electromagnetic irons on both sides. The magnetic coil on which side is energized will attract the valve body to which side. By controlling the movement of the valve body, different oil discharge holes can be opened or closed, and the oil inlet hole is normally open. Hydraulic oil will enter different oil discharge pipes, and then the piston of the oil cylinder will be pushed by the pressure of the oil. The piston will drive the piston rod, and the piston rod will drive the mechanical device.
Anwochi AVEENTICS first level distributor of solenoid valves/pneumatic valves-Shanghai Nianci Machinery Equipment Co., Ltd. - Dedicated to serving youIt is one of the brands under Emerson.
AVEENTICS solenoid valve main classification
1. Electromagnetic valves can be classified into three main categories based on their principles:
Direct acting type
Principle: When powered on, the electromagnetic coil generates electromagnetic force to lift the closing member from the valve seat, and the valve opens; When the power is cut off, the electromagnetic force disappears, and the spring presses the closing member against the valve seat, causing the valve to close.
Characteristics: It can work normally under vacuum, negative pressure, and zero pressure, but the diameter generally does not exceed 25mm.
Step by step direct action type
Principle: It is a combination of direct action and pilot operated principle. When there is no pressure difference between the inlet and outlet, after being energized, the electromagnetic force directly lifts the pilot small valve and the main valve closing member upward in sequence, and the valve opens. When the inlet and outlet reach the starting pressure difference, after being energized, the electromagnetic force pilot small valve, the lower chamber pressure of the main valve rises, and the upper chamber pressure drops, thereby using the pressure difference to push the main valve upwards; When the power is cut off, the pilot valve uses spring force or medium pressure to push the closing member downwards, causing the valve to close.
Features: It can also operate under zero pressure difference, vacuum, and high pressure, but with high power, it must be installed horizontally.
The AVEENTICS solenoid valve has a sealed chamber with through holes at different positions, each connected to a different oil pipe. The middle of the chamber is a piston, and there are two electromagnets on both sides. The valve body will be attracted to which side when the magnetic coil on the other side is energized. By controlling the movement of the valve body, different oil discharge holes can be opened or closed. The oil inlet hole is normally open, and hydraulic oil will enter different oil discharge pipes. Then, the pressure of the oil will push the piston of the cylinder, which in turn drives the piston rod, which drives the mechanical device. In this way, the mechanical motion is controlled by controlling the current on and off of the electromagnet.
| 5813180000 |
| 0820019980 |
| 1827414303 |
| R412006265 |
| R412006124 |
| 5813221400 |
| 5811110420 |
| R480061859 |
| 0822121011 |
| 0822393208 |
| R412007045 |
| R412007075 |
| R412007209 |
| 1829207068 |
| R961400139 |
| R480079809 |
| R431002640 |
| 1825503149 |
| 5813180000 |
| 0820019980 |
| 1827414303 |
| 1827414304 |
| 0822123004 |
| 820024997 |
| 821300856 |
| 0822123004 |
| 0822341127 |
| R412014664 |
| R412014600 |
| 0822345517 |
| 0822123006 |
| R480048506 |
| 5813220000 |
Installation precautions for AVEENTICS solenoid valve
1. During installation, it should be noted that the arrow on the valve body should be consistent with the flow direction of the medium. It cannot be installed in places with direct dripping or splashing water. The solenoid valve should be installed vertically upwards;
2. The solenoid valve should ensure normal operation within a fluctuation range of 15% -10% of the rated voltage of the power supply;
3. After the installation of the solenoid valve, there should be no reverse pressure difference in the pipeline. And it needs to be powered on several times to reach the appropriate temperature before it can be officially put into use;
4. Before installing the solenoid valve, the pipeline should be cleaned. The incoming medium should be free of impurities. Install a filter in front of the valve;
The solenoid valve has a sealed chamber with through holes at different positions, each connected to a different oil pipe. The middle of the chamber is a piston, and there are two electromagnets on both sides. The valve body will be attracted to which side when the magnet coil on the other side is energized. By controlling the movement of the valve body, different oil discharge holes can be opened or closed. The oil inlet hole is normally open, and hydraulic oil will enter different oil discharge pipes. Then, the pressure of the oil will push the piston of the oil cylinder, which in turn drives the piston rod, which drives the mechanical device. In this way, the mechanical motion is controlled by controlling the current on and off of the electromagnet. Welcome to inquire and place ordersGerman Anwochi cylinder AVEENTICS solenoid valve Shanghai agent sales - Shanghai Nianci Machinery Equipment Co., Ltd. - Dedicated to serving you