Technical parameters of anti metal droplet impact performance tester:
Welding nozzle diameter (1.2 ± 0.1) mm;
Motor wire feeding rate (10 ± 1) g/min;
Droplet mass (0.50 ± 0.05) g;
Droplet frequency: 20 drops/(min ± 3s);
Starting distance from metal wire to welding torch nozzle: 12mm;
Welding torch dark blue flame core length: 8mm;
Thermal conductivity of sensor support: (0.125 ± 0.015) W/(m.k);
The surface groove size is (13.5 * 11) mm;
Temperature sensor: imported, thermal response time ≤ 0.3s;
Dimensions: 667mm * 330mm * 436mm;
’Power supply: 230VAC, 50HZ.
EN348
Machine principle of anti metal droplet impact performance tester:
This device is used to check the protective effect of protective clothing under the thermal shock of molten metal droplets. Click to drive the lever at a constant speed to approach the acetylene/oxygen flame, and the rod will melt in contact with the flame; Molten metal droplets fall into a funnel and enter the sample; The sample is installed on the vertical surface of the heat flow sensor; The dehumidification temperature of the heat flow rate is already recorded when the first metal droplet falls off; The continuous impact of melted metal droplets causes the temperature of the heat flow sensor to rise; The amount of droplets needs to be increased to increase the temperature of the heat sensor at a rate of 40K in order to obtain significant test results.
Standard configuration of anti metal droplet impact performance tester:
Convenient testing platform
Clamp the sample fixture
Motor control system
Flame generation system
Pneumatic Control
Digital, programmable flow meters
Testing software developed based on NI platform
Industrial grade control host