Welcome Customer !

Membership

Help

Beijing Tiansi Yida Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Beijing Tiansi Yida Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 1802, Building 4, Da Yin Ming Building, No. 60 Da Da Dong Road, Haidian District, Beijing

Contact Now

Animal Physiology Remote Sensing System

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Animal physiological telemetry system: The measurement technology that remotely and wirelessly collects data on the emission of implanted sub electrons in animals is called telemetry technology. The TSE Slar telemetry system adopts advanced technology to improve system performance, convenience, and stability, surpassing any telemetry acquisition system in the existing basic research field.

Product Details

Slar small animal implantable telemetry system

Animal Physiology Remote Sensing Systemtelemetry

The measurement technology for remote wireless collection of implanted electron emission data in animals is called telemetry technology. The TSE Slar telemetry system adopts advanced technology to improve system performance, convenience, and stability, surpassing any telemetry acquisition system in the existing basic research field.

The pressure sensor of the catheter can solve various problems of traditional liquid filled catheters, such as slow frequency response, pressure, and noise generated by animal movement.

A receiver can monitor up to 256 animals. And 256 animals can be in one area or multiple areas at the same time.

The emission range of implanted particles in animals is 5 meters, without the need for a special platform or removal of the animal from the feeding cage for data collection.

The price of the rat Slar telemetry system is only a fraction of similar products. The price of implants is only equivalent to the maintenance cost of similar products. Based on the TSE * manufacturing process, all Slar emitters are disposable products, so they can be directly discarded after the experiment without any maintenance costs. This can save both repair time and repair costs. When conducting large-scale experiments, this advantage becomes particularly evident and can help you save a significant amount of money. The implanted memory chip can store data for 2 hours. The Slar telemetry system control program can independently control the acquisition parameters and time of each implanted subunit. After the program is completed, each implant can upload the collected data to the computer according to the main program. The core technology of Slar implants is that each implant contains its own memory. This is adopted in telemetry technology, where data collection can continue even if the animal is moved out of the receiving range, and when the animal is returned to the receiving range, the collected data can be uploaded to the computer on its own. Therefore, users can collect data without worrying about whether animals are within the collection range.

Analyze software modules

Animal Physiology Remote Sensing Systemblood pressure module

The blood pressure measurement module can generate multiple arterial and venous pressure data from the collected blood pressure data through built-in software

data

The software can also automatically convert blood pressure signals into various commonly used physiological parameters and easily import them into other programs

Conduct further analysis.

Arterial pressure conversion parameter

Heart rate (HR)

Maximum/Min Pressure

Mean Arterial Pressure (MAP)

Systolic and diastolic pressure

The maximum rate of increase and decrease (Max./Min. dp/dt)

Pulse Height

Notch Pressure

Systolic, Diastolic, Cycle Duration

Time to Peak

Election time

Percentage Recovery

Conversion parameters for venous pressure

Heart rate (HR)

Zui Big/Zui Small Pressure

Mean Pressure (Pmean)

End systolic pressure (Pes.)

End diastolic pressure (Ped)

The maximum rate of increase and decrease (Max. Min. dP/dt)

Developed Pressure

Rising/falling rate (dP/dt)

Contractility Index

Relaxation Index

Systolic, Diastolic, Cycle Duration

Tension Time Index

Relaxation Time

Isovolumetric Time

Tau(Weiss, Logistics, Glantz, Mirsky)

ECG module

The ECG software module can automatically analyze electrocardiogram data from multiple species. Professional analysis templates can accurately record the occurrence, duration, and amplitude of PQRST.

Users can also customize analysis templates based on electrocardiogram files and save them for future use.

The main parameters include average heart rate, heart rate classification, as well as the ability to remove outliers and extract raw data. Data can be exported as images or text files.

The software module is compatible with all data acquisition and analysis systems of Slar telemetry systems.

The ASCII text import module can convert electrocardiogram data collected by other programs into text format.

The standard PV data for rats includes: left ventricular pressure (LVP), left ventricular volume (LVV), phase, amplitude, rise/fall rate (dP/dt), and XY distribution maps of left ventricular pressure and volume. The blood pressure volume loop (PV Loop) automatic annotation function can also be used to display key descriptions and upload edited data in real-time to online journals for comparison.

ECG conversion parameters

Heart rate

R-wave time (Time at R)

R-R Interval

QT,QTC,QR,PR,R-R 间期 (QT,QTC,QR,PR,R-R Internal)

ST segment

T. TP, QSR Duration (T, TP, QSR Duration)

QATN

P波、R波、T波振幅 (P,R,T Amplitude)

ST Height

HRV Heart Rate Variability (HRV *) Calculations

R-wave interval variation (Delta R-R)

Low/High Power

Mean Power at Low Band/High Band

*Note: Both EEG and blood pressure records can be exported to HRV.