- Phone
-
Address
No. 26 Yerong Road, Yexie Town, Songjiang District, Shanghai
Shanghai Shangyi Education Equipment Manufacturing Co., Ltd
No. 26 Yerong Road, Yexie Town, Songjiang District, Shanghai
Air conditioning refrigeration control training device (export version) | Knowledge of cold and heat technology training equipmentIt is a product developed in accordance with the requirements of the Ministry of Education's "Plan for Revitalizing the Curriculum Reform and Textbook Construction of Vocational Education in the 21st Century", based on abilities and employment orientation, closely combined with production reality and the skill requirements of vocational positions, and developed according to the teaching and practical training requirements of vocational education. Suitable teaching and training equipment for refrigeration technology, refrigeration fluid machinery, principles and maintenance of household refrigeration equipment, cold storage and refrigeration technology, and training for refrigeration equipment maintenance workers (primary, intermediate, advanced) in vocational colleges and vocational schools. To cultivate applied talents who master the theoretical knowledge and practical skills of air conditioning and refrigeration technology, and are engaged in the technical upgrading, renovation design, installation, commissioning, maintenance, repair, technical management, and other aspects of air conditioning and refrigeration equipment and systems.
Air conditioning refrigeration control training device (export version) | Knowledge of cold and heat technology training equipmentAlso suitable for technical schools, vocational training schools, vocational education centers, appraisal stations/institutes, refrigeration majors such as "Refrigeration Equipment Maintenance Workers (Junior, Intermediate, Advanced)" and "Principles and Maintenance of Household Refrigeration Equipment" 《Operation, installation, and maintenance of refrigeration and air conditioning units》Courses such as "Small Refrigeration Devices" and "Small Refrigeration and Air Conditioning Devices".
reference image
This training device mainly consists of a power control screen, a training table, a fault box, a testing box, etc.
The control screen is made of aluminum alloy structure and aluminum panel, providing AC power supply, various testing instruments and training devices for practical training. The specific functions are as follows:
The training table is made of aluminum alloy double-layer matte dense pattern spray coating structure, waterproof, wear-resistant high-density board,Sturdy structure, beautiful and elegant shape; The desktop is used to install the power control screen and provide a spacious and comfortable workspace. The training table is also equipped with four universal wheels, which are easy to move and fix, and are conducive to the layout of the training room.
Provide multiple fault connection points for simulated air conditioning and simulated refrigerators, and provide common electrical circuit connections for air conditioning and refrigerator to simulate system faults; The types of settings include: power circuit, temperature sensing circuit, drive circuit, compressor protection circuit, indoor fan speed control circuit, etc. Simulate fault switch values for air conditioning and refrigerator, meeting the requirements for multi-point fault setting.
Simulation fault setting instructions for heat pump type split air conditioner
number |
Fault simulation explanation |
fault phenomenon |
K1 |
Refrigerator power detection connection |
The computer board cannot be powered on, and the whole machine does not work |
K2 |
External fan circuit detection connection |
The computer board cannot be powered on, and the whole machine does not work |
K3 |
Air conditioner, compressor detection connection |
The computer board cannot be powered on, and the whole machine does not work |
K4 |
Four way valve detection connection |
No+5V DC power output, the whole machine does not work |
K5 |
Indoor fan high wind detection connection |
|
K6 |
Indoor fan stroke detection connection |
|
K7 |
Indoor fan low wind detection connection |
|
K8 |
Indoor pipe temperature sensor short circuit |
|
K9 |
F1 startup capacitor open circuit |
Motor cannot start, motor does not work |
K10 |
F1 running winding open circuit |
Motor cannot start, motor does not work |
K11 |
Four way valve YV coil open circuit |
The four-way valve does not work and does not function during heating conditions |
K12 |
Protection relay SAT open circuit |
The compressor cannot work |
K13 |
Indoor temperature sensor short circuit |
The compressor cannot work, the starting current is too high |
K14 |
Compressor operation winding CM open circuit |
The compressor cannot work, the starting current is too high |
K15 |
Quick freezing circuit detection connection |
|
K16 |
Relay RLY5 coil operation detection |
When simulating indoor speed regulation, high-end wind speed does not work |
K17 |
Relay RLY4 coil operation detection |
When simulating indoor speed regulation, mid-range wind speed does not work |
K18 |
Relay RLY3 coil operation detection |
When simulating indoor speed regulation, the bottom wind speed does not work |
K19 |
Relay RLY2 coil open circuit |
The four-way valve body does not move |
K20 |
Relay RLY1 coil operation detection |
The compressor is not working |
|
|
|
Refrigeration Training Project
Basic Skills Training for Junior Technicians
Intermediate Skills Training (Design, Installation, Debugging, and Maintenance)