Acetone gas alarm probe C3H6O point type combustible gas detector
The acetone gas alarm can effectively detect the concentration of acetone gas, preventing excessive concentration of acetone gas after gas leakage. The acetone gas alarm is composed of two parts: a gas alarm controller and a gas detector. The gas detector is installed at the gas leak detection site and can achieve real-time detection of gas concentration through the core component gas sensor. It can also work independently. The gas alarm controller can be placed in the duty room, receive the concentration detected by the gas detector, and realize the display of concentration and the sound and light alarm function after the concentration exceeds the standard. It can also be linked to external equipment (such as solenoid valves, exhaust fans, spray devices) for uploadingPLC、DCS、 Fire protection system, etc.
Acetone gas detectorProduct Features:
1. Using imported components, stable performance and low power consumption.
2. High precision and fast response speed.
3. Three wire 4-20mA standard signal output; M-BUS standard signal output.
4. The setting and modification of its own parameters can be achieved through the instructions of the controller.
5. Zero calibration, modification of alarm points, self check, accurate 4-20mA output can be achieved through remote control without opening the cover.
6. On site LCD concentration display and more intuitive light indication.
7. On site sound and light alarm (optional), easy installation and long transmission distance.
8. The detector has a simple and elegant appearance.
Acetone gas alarm probe C3H6O point type combustible gas detectorTechnical parameters:
Gas detection:acetone
Calibration gas: isobutane
Detection principle: catalytic combustion
Detection range:0-100%LEL
Alarm value: low alarm25%LEL;college application counseling50%LEL
Power supply:DC24V±15%
Communication method: Three wire system 4-20mA standard signal; M-BUS dual bus
Signal output: a set of passive normally open signals; A set of active warning light signals
accurate indeed Degree:±5%FS
Response time: ≤30s
Material: Die cast aluminum
Explosion proof link thread:G1/2″
Explosion proof grade:Exd II C T6 Gb
IP rating: IP66
Operating Temperature-40℃~70℃
Humidity range:≤95%RH
Pressure range:86Kpa to 106Kpa
Storage temperature:-25℃~55℃
Installation: Wall mounted, pipe holding, pipe penetrating
Overall dimensions:190mm×145mm×92mm
Application standards:GB15322.1-2003,GB16808-2008