ATOS solenoid valve SDPH L 2 71 1/E-X 24 DC
Selection criteria for solenoid valves:
1. Select the solenoid valve based on pipeline parameters: diameter specification (i.e. DN), interface method: determine the diameter (DN) size according to the on-site pipeline inner diameter size or flow requirements; Interface method, generally>DN50 requires flange interface, ≤ DN50 can be freely selected according to user needs.
2. Select solenoid valves based on fluid parameters: material, temperature group: corrosive fluid: corrosion-resistant solenoid valves and all stainless steel are recommended; Edible ultra clean fluid: It is recommended to use food grade stainless steel solenoid valves; High temperature fluid: It is necessary to choose electromagnetic valves made of high-temperature resistant electrical materials and sealing materials, and to choose piston type structures;
Fluid state: up to gaseous, liquid, or mixed state, especially when the diameter is greater than DN25, it must be distinguished;
Fluid viscosity: Usually below 50cSt, it can be selected. If it exceeds this value, a high viscosity solenoid valve should be used.
3. Selecting solenoid valves based on pressure parameters: principles and structural types
Nominal pressure: This parameter has the same meaning as other general valves and is determined based on the nominal pressure of the pipeline;
Work pressure: If the work pressure is low, choose the direct action or step-by-step direct action principle; When the low working pressure difference is above 0.04Mpa, direct acting, step-by-step direct acting, and pilot operated can all be selected.
4. Electrical selection: The voltage specifications should preferably be AC220V or DC24, which are more convenient.
5. Choose based on the duration of continuous work: normally closed, normally open, or continuously powered on
When the solenoid valve needs to be opened for a long time and the duration exceeds the closing time, the normally open type should be selected;
If the opening time is short or the opening and closing time is not long, choose the normally closed type;
However, for some working conditions used for safety protection, such as furnace and kiln flame monitoring, the normally open type cannot be selected, and the long-term electrified type should be selected.
Select functions according to environmental requirements: explosion-proof, check, manual, waterproof fog, water shower, diving.
ATOS solenoid valve SDPH L 2 71 1/E-X 24 DC
DPHI-2710-X-110/50/60AC
DPHI-2710-X-120/60AC
DPHI-2711/1/H-X-24DC
DPHI-2711/D-00
DPHI-2711/DE-X-120/60AC
DPHI-2711/DE-X-24DC
DPHI-2711/DH-X-110/50/60AC
DPHI-2711/DH-X-110/50/60AC/PE
DPHI-2711/DH-X-120/60AC
DPHI-2711/D-X-120/60AC
DPHI-2711/D-X-24DC
DPHI-2711/D-XK-12DC
DPHI-2711/EWP-X-120/60AC
DPHI-2711/E-X-110/50/60AC
DPHI-2711/E-X-120/60AC
DPHI-2711/FI/NC-X-24DC
Dphi- 2711 / FI / no- 00
DPHI-2711/FI/NO-X-24DC
DPHI-2711/H-X-24DC
DPHI-2711-00
DPHI-2711-S PIL
DPHI-2711-X-120/60AC
DPHI-2711-X-24DC
DPHI-2713/1/DHWP-X-120/60AC
DPHI-2713/1/DH-X-110/50/60AC
DPHI-2713/1-X-110/50/60AC
DPHI-2713/1-X-230/60AC
DPHI-2713/D-00
DPHI-2713/DE-X-12DC
DPHI-2713/DE-X-230/50/60AC
DPHI-2713/DH-X-110/50/60AC/PE
DPHI-2713/DH-X-120/60AC
DPHI-2713/D-X-110/50/60AC
DPHI-2713/D-X-120/60AC