- Phone
-
Address
Room 403, Unit 1, Building 1, Block B, Fangyi Science and Technology Park, No. 222 Xing'an Street, Yuhua District, Shijiazhuang City, Hebei Province
Emery (Hebei) Technology Co., Ltd
Room 403, Unit 1, Building 1, Block B, Fangyi Science and Technology Park, No. 222 Xing'an Street, Yuhua District, Shijiazhuang City, Hebei Province
Features:
1)Soil gas sampling and6The parameter analyzer is integrated into one, currentlyguoThere is no such thing as' inside and outside 'yeterHome can do it.
2)It is incredible that integrated instruments are like children's suitcases, lightweight to carry and can be carried by hand.
3)6Measurable soil gas parameters: sampling volume,PID,CO2Oxygen,CH4TheH2S.
Suitable for rapid sampling, detection and analysis of soil environment (including soil samples and soil gas). real-time displayVOCTheCO2TheO2TheCH4TheH2SSuitable for soil and soil gas sampling analysis in industries such as environmental protection, geology, agriculture and forestry, archaeology, etc.
Technical parameters:
1.Real time display of sampling flow rate and pressure, real-time displayVOCTheCO2TheO2TheCH4TheH2STesting data;
2. Range of flow display instrument0~5000ml/minReal time display of exhaust flow rate;
3.The entire pipeline connection material is made of inert material (special)fuDragon tube or stainless steel parts);
4.can be100~500ml/minWithin the scope and500~3000ml/minWithin the scopejingAccurate regulation; For two sampling pipelines, each with a separate rangeyiArticle;
5. on one's ownsheCompare the interval time and stable range; Automatically compare data to determine if well flushing has ended, and once stablefaProvide prompt information and record readings;
6. The soil gas sampling on-site analyzer is designed as an integrated unit, and the sampling flow rate can be automatically adapted. The pump can be automatically started, stopped, and the pumping flow rate can be adjusted according to the well conditions;
7.The instrument is equipped with an integrated lithium-ion battery, which can work continuously for a minimum of24Hour; On site analysis:
8.Display: Screen4.3Inch,TFTCapacitive touch screen;
9.VOC(PID)Range:0-20PPM,ZUISmall exploration measurement1.5ppb,
10.CO2Range:0-1000 ppm,JINGDegree:±3%FSResolution:1 ppm;
11.Oxygen: Range0-35%VOL, Resolution0.1%, accuracy±0.5%;
12.CH4Range:0-5VOL %,JINGDegree:±5%FSResolution:0.01 VOL %;
13.H2S:0-10 ppm, JINGDegree:<2%, Resolution< 0.01 ppm;
14.The air inlet is equipped with a drying device for easy replacement, and the replacement frequency should not be less than12Hourly working conditions required;
15.The size of the on-site analyzer for soil gas sampling shall not exceed30*15*22cmCan walk with one hand alone;
16.Soil sampling method: impact sampling method, ensuring the integrity of the soil surface and the undisturbed state of the soil sample, and achieving waterless operation during the sampling process;
17.Soil sampling method: Unidirectional liner design for easy retrieval of soil samples;
18. Soil sampling power type and endurance:2group4000mAhPowered by lithium batteries, sustainable use4Hour;
19.Soil samplingSHENDegree:0~1.5m;
20.Outer diameter of soil sampling drill rod: 42mm;
21.Soil sampling core diameter: 35mm;
22.Soil sample collection rate:> 97%;
23.Connection method of soil gas sampling kit:5/8Inch thread
24.Diameter of soil gas sampling drill bit:≤8.5cm
25.Length of soil gas sampling handle: not greater than46cm
26.Soil columnar sampling drill bit: not larger than diameter5.1cm*15.3cm
27.Soil gas sampling drill rod:≥1rice
28.Length of soil gas sampling wrench:≤31cm