experimentThe air used in the room has strict requirements. In order to ensure the normal operation of experiments such as GC chromatography analysis, it is necessary to treat the air we come into contact with in daily life, so that it can be efficiently used and thus "born"air generatorThe air generator has replaced the traditional high-pressure air cylinder.
1. Air Generator GC Gas Chromatography Special
Output pressure: 00.4MPa
Flow rate: 3L/min, 5L/min
l Using an oil-free compressor, it automatically adsorbs and removes hydrocarbons, esters, oils, and other substances from the air, greatly improving air quality
l Built in stainless steel gas storage tank, non rusting and non corrosive, ensuring high cleanliness of the output gas
l Automatic drainage valve, no need for manual drainage
l Dual filter, two-stage voltage regulation, high output pressure accuracy
2. A-40Pro model air generator
Output pressure: 0~0.6MPa
Flow rate: 0~45L/min
l Can be used 24 hours without stopping the machine
l Sufficient gas volume, high pressure, can drive multiple high-purity nitrogen generators (without built-in air compressor)
experimentThe air used in the room has strict requirements. In order to ensure the normal operation of experiments such as GC chromatography analysis, it is necessary to treat the air we come into contact with in daily life, so that it can be efficiently used and thus "born"air generatorThe air generator has replaced the traditional high-pressure air cylinder.
7 days * 24 hoursProduct consultation: 185 * 0177 * 0605,185*0177*0601
TB Enterprise DIAN: Runrong Mall(Similar products are available for sale)
Tip:
When configuring an air generator for gas chromatography (GC), it is necessary to meet the strict requirements of the instrument for auxiliary gas/carrier gas, and its performance directly affects the sensitivity, baseline stability, and data reliability of detectors (such as FID, FPD).
The catastrophic consequences of inferior air generators
1. FID nozzle blockage: The nozzle needs to be disassembled and cleaned every month due to oil vapor carbon deposition, resulting in a shutdown loss of ≥ 50000 yuan/year.
2. Baseline noise surge: THC exceeds the standard with a 50% decrease in signal-to-noise ratio (S/N), and the detection limit (LOD) cannot be met.
3. Risk of flameout: Moisture condensation leads to unstable flames and analysis interruption.
Configuring an air generator for GC is not about purchasing accessories, but about purchasing insurance for data accuracy.