8500 series online residual chlorine transmitter (polarographic principle)

NegotiableUpdate on 11/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Introduction: 8500 series online residual chlorine transmitter (polarographic principle) Picture 8500A online residual chlorine transmitter 8500B online residual chlorine transmitter model 8500A 8500B Measurement range 0-20mg/L HOCL 0-10mg/L PH 0-14PH Temperature 0-99.0 ℃ Output signal 4-20mA (load<750) Alarm relay 220V, 7A power supply AC 220V earth 22V, 50Hz 1 Hz

Product Details

Picture of 8500 series online residual chlorine transmitter (polarographic principle)

8500A型在线余氯变送器

8500A online residual chlorine transmitter
8500B型在线余氯变送器

8500B online residual chlorine transmitter

model 8500A 8500B
measurement range 0-20mg/L
HOCL 0-10mg/L
PH 0-14pH
temperature 0-99.0℃
output signal 4-20mA (load < 750 Ω)
Alarm relay 220V,7A
power supply AC 220V 土 22 V, 50Hz ± 1 Hz, 24VDC (可选)
communication interface RS485 (optional)
Protection level IP65
Overall dimensions 146x146x108mm 146x146x150mm
cutout size 138x138mm
working conditions Environmental temperature: 0-60 ℃; Relative humidity<85%
Scope of application Electricity, waterworks, hospitals


8501 series online residual chlorine electrode (polarographic principle) picture

8501在线余氯电极


Online residual chlorine electrode



8500系列在线余氯流通池
8500 series online residual chlorine circulation pool

model 8501
measurement range 0.005-20mg/L ( ppm )
precision 2%/± 10ppb
Storage temperature ﹣20~60℃
Operating temperature 0-45℃
Sample temperature 0-45℃
HOCI response time 90%<90 seconds
Correction method and interval Laboratory comparison method, 2 months/time
maintenance interval Replace the membrane and electrolyte every 6 months