- Phone
-
Address
7F, No. 1986 Shangcheng Road, Lujiazui International Financial Center, Shanghai
Shanghai Jiggesen Industrial Co., Ltd
7F, No. 1986 Shangcheng Road, Lujiazui International Financial Center, Shanghai
Mrogi Quality Assurance3M pressure steam sterilization biological culture indicator
Packaging specification: 100 pieces/box
Model: 12621262-S
Strain: Bacillus subtilis ATCC7953
Spore content: 105-106
Cultivation time: 48 hours
Scope and purpose of use:
3M pressure steam sterilization biological culture indicatorUsed for monitoring the sterilization effect of exhaust pressure steam at 121 degrees Celsius and pre vacuum pressure steam at 132 degrees Celsius.
Product features:
1. Composed of Bacillus subtilis ATCC7953 spores, culture medium, and plastic shell integrated together
2. Self contained design; Prevent secondary pollution
3. Standard type: start reading within 24 hours, read results within 48 hours
4. The improved culture medium has stable quality and more accurate monitoring
Packaging: 100 pieces/box, 4 boxes/box
Product Description:
3M steam sterilization biological indicator, composed of thermophilic fat bacteria spore sheets, culture medium, and plastic shell. Under saturated steam conditions at 121 ℃, the survival time is ≥ 5 minutes and the killing time is ≤ 15 minutes.
Usage:
1. Place the pressure steam sterilization biological culture indicator in a standard test kit
2. According to national regulations, place the test kits in different positions inside the pot
3. Sterilization completed, remove the biological indicator
4. Squeeze the ampoule inside and place it together with a control tube in a 56 ℃ incubator
5. 48 hours later, read the results
How to read:
After cultivation, if the indicator tube does not change color (turns purple), it indicates that sterilization has passed; After cultivation, if the indicator tube changes color (yellow), it indicates that sterilization has not passed (the reason for sterilization failure must be promptly identified). The control tube cultured at the same time should be positive (yellow). If it is negative, the possible reasons are: the cultivation conditions do not meet the requirements; There is a problem with the biological indicator; (The negative cause should be identified in a timely manner)
How to discard: Positive indicators must be sterilized (at least 15 minutes at 121 ℃) and discarded

Mrogi Quality provides the following 3M consumables
3M1322 pressure steam sterilization indicator tape (specification 2.4cm X 55m, 20 rolls/box)
3M1322L sterilization instruction label (30 sheets/sheet, 50 sheets/book, 15 books/box)
3M1292 rapid biological indicator (50 tubes/box, 4 boxes/box)
3M1294 Rapid Biological Indicator (50 tubes/box, 4 boxes/box)
3M1262 Biological Culture Indicator (100 tubes/box, 4 boxes/box)
3M1264 Biological Culture Indicator (100 tubes/box, 4 boxes/box)
3M1276 Biological Testing Kit (25 packs/box)
3M1296 Biological Testing Kit (25 packs/box)
3M1243A Class 5 Chemical Crawler Card (2 packs/box)
3M41382 Comprehensive PCD Challenge Test Kit (64 packs/box)
3M00135BD test kit (30 packs/box, 4 boxes/box)
3M1235LF standard BD test kit (30 packs/box)
3M ATP Fluorescence Detector Detection Rod (100 pcs/box)
3M41360 Chemical Testing Kit (64 packs/box)
3M1492V Rapid Biological Indicator (50 pcs/box)
3M1496V Extreme Biological Test Kit (24 packs/box)
3M41482V Rapid Chemical Comprehensive Challenge Package
3M1295 Biological Indicator
3M1298 Biological Testing Kit