The 1332 pressure transmitter adopts an imported silicon piezoresistive isolation membrane oil filled core as the signal measurement element. The sensor signal is converted into a standard signal output through a signal processing circuit. The signal processing circuit located inside the stainless steel shell converts the sensor signal into a standard output signal. The product has undergone strict testing of components, semi-finished products, and finished products, as well as long-term aging and other process screening. It has high overall performance, good long-term stability, strong anti-interference ability, and can work safely and reliably in relatively harsh environmental conditions for a long time

1332 rugged pressure transmitter
Non corrosive gas and liquid pressure measurement for 316L stainless steel.
Specially designed for pressure measurement and control in outdoor industrial sites with harsh environments.
Characteristics of 1332 rugged pressure transmitter
Wide measurement range, aluminum cast explosion-proof shell, diverse pressure interface forms;
The output signal forms are diverse, and can be adjusted and displayed on site;
Multiple protections and strong resistance to electromagnetic interference;
Multiple pressure types including gauge pressure, absolute pressure, and sealing reference pressure;
| Technical Parameter | |
|---|---|
| Range: | -0.1~0 or 0~0.01 or 0~100MPa |
| Allow overload: | ≤ 1.5 times the rated range |
| Pressure type: | Gauge pressure, absolute pressure, sealing reference pressure type |
| accuracy: | ± 0.25% (typical) ± 0.5% (maximum) |
| Long term stability: | ± 0.1% F.S/year (typical) ± 0.2% F.S/year (maximum) |
| Working temperature: | -20℃~80℃ |
| Storage temperature: | -40℃~120℃ |
| Power supply: | 15-30VDC (intrinsically safe type powered by safety barriers) |
| Output signal: | 4~20mA 0~10/20mA 0/1~5VDC |
| Pressure interface: | M20*1.5; G1/2 or user selected |
| Shell material: | 304 stainless steel |
| Membrane material: | 316l stainless steel |
| O-ring seal: | VITON |
| Cable: | polyethylene |
| Insulation resistance: | 100MΩ 100VDC |
| Shell protection level: | IP65 |

| Selection code | ||||||||
|---|---|---|---|---|---|---|---|---|
| 1332- | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
| Range -0.1~0 or 0~0.01 or 0~100MPa (X: indicates the actual measurement range is online) | ||||||||
| 1 | XK | (0-x)Kpa | ||||||
| XM | 0-x)Mpa | |||||||
| 2 | Appearance specifications | |||||||
| A | 2088 industrial instrument housing types (made of cast aluminum alloy material) | |||||||
| B | 2088 industrial instrument housing digital display type (made of cast aluminum alloy material) | |||||||
| 3 | power supply | |||||||
| D1 | 15~30VDC | |||||||
| D3 | Other power supply methods | |||||||
| 4 | output signal | |||||||
| S1 | 4~20mADC | |||||||
| S2 | 1~5VDC | |||||||
| S3 | 0~5V | |||||||
| S4 | 0~10mADC | |||||||
| S5 | 0~20mADC | |||||||
| 5 | accuracy class | |||||||
| A | 0.1%F.S | |||||||
| B | 0.25%F.S | |||||||
| C | 0.5%F.S | |||||||
| 6 | Threaded interface | |||||||
| J1 | M20 × 1.5 external thread | |||||||
| J2 | G1/2 external thread | |||||||
| 7 | pressure type | |||||||
| G | Gauge pressure (* regular option) | |||||||
| A | Absolute pressure | |||||||
| S | Sealing reference pressure | |||||||
| 8 | OEM customization | |||||||
| / | Regular shipment without customized content | |||||||
| A | Nameless light plate customized product | |||||||
| B | Designated nameplate, designated trademark product | |||||||