HORIBA/Horiba SLIA-300Silicon dioxide concentration meterProduct details:
SLIA-300 meets the customer demand for measuring ultra-low density silica with high sensitivity of 0.01 µ g/L (0.01 ppb). Ultra pure water used in semiconductor production processes can be further improved by using ion exchange resinsPurification. Rapid capture of dissolved silica from ion exchange resins can control the quality of ultrapure water, which is crucial for the manufacturing process.HORIBA Advanced Techno has developed and adopted a new 'long optical path length measurement unit' that can perform high-sensitivity measurements on ultra-low density silica, while also providing a compact desktop model,To enhance practicality.
This product has a series of standard functions such as self diagnosis and high speedNew performance improvements such as responsiveness and high sensitivity provide stronger support for pure water processes in semiconductor production processes.
Product Features:
High sensitivity and high repeatability
The application of fiber optic technology ensures a long optical path of about 1m, achieving ultra low density and high sensitivity response. This product can ensure a 5-minute high-speed measurement process and achieve a repeatability accuracy of ± 2% F.S. within the measurement range of 0-2 µ g/L.

Desktop model compact design
The flexible structure of the long optical path length measurement unit has also achieved revolutionary compact design. This desktop model is suitable for various installation conditions, including narrow spaces.

Reduce reagent consumption to 1/5
In order to reduce reagent consumption to 1/5 of the previous level, the reaction unit has been improved and separated from the measuring cell. In addition, the measuring unit has been changed to a pipeline type. The use of a 'long optical path length measurement unit' can significantly reduce the amount of reagentsThe operating cost.

Reduce reagent consumption by more than half
Not only does it reduce the consumption of reagents, but it also reduces the consumption of sample water. By adopting a 'long optical path length measurement unit', the consumption of expensive pure water (used as sample water) has been reduced by 60%.
Self diagnostic function for concentration meter misoperation
Perform self diagnosis for erroneous operations, such as sample water and/or reagent injection, calibration errors, temperature detection within the unit, and light source errors. When an error is detected, the warning light lights up and displays a text message.
Automatic calibration achieves excellent maintainability
Continuously perform zero point calibration to check transmitted light and correct turbidity.
Allow up to six measurement points (optional)
Up to six measurement points can be set. A single unit can perform multi-point measurements.
Using a monochromatic semiconductor light source to provide stable light output and longer lifespan.
Long path length measurement unit: capable of detecting as low as 0.01 µ g/L
The measuring unit is a double-layer structure, in which a transparent fluorocarbon resin tube passes through a stainless steel tube. Due to the difference in refractive index between the fluorocarbon tube and the surrounding air, light entering from one side of the tube remains in the tube before reaching the other sideRepeated reflection.
This optical transmission mechanism is the application of fiber optic efficiency and low blocking principle, achieving higher detection sensitivity and high repeatability.

This long light path measurement unit adopts a flexible pipeline structure and is compact in size. By storing a 1-meter-long unit in a compact desktop body, the unit size has been successfully reduced to 1/8 of the previous generation model. In addition, the pipeline structure of the measurement unit can effectively reduce operating costs: the consumption of color reagent and sample water is reduced to 1/5 and 1/2 of the previous amount, respectively.
HORIBA/Horiba SLIA-300Silicon dioxide concentration meterProduct parameters: