Product Overview:
1000A high current generatorIt is a specialized equipment designed and manufactured specifically for electrical equipment testing such as current load testing and temperature rise testing of various switches, current transformers, and other electrical equipment by the power sector and industrial and mining enterprises.
This series of products adopts an integrated or split structure depending on the size and weight of the product, with features such as infinite adjustment of output current, balanced current rise, wide range of load changes, reliable operation, easy operation, and safety. It is an ideal equipment for conducting flow or temperature rise tests in industrial and mining enterprises.

1000A high current generatorFunctional features:
1. Adopting energy-saving self coupling voltage regulator and high permeability current regulator.
2. The instrument is a 0.5 level digital meter with true effective value indication and precise measurement.
3. Equipped with a digital stopwatch, it can meet the requirements of time measurement.
4. It has the characteristics of high output power, low additional loss, strong overload resistance, easy operation, clear reading, and flexible movement.
5. Suitable for power system technicians to inspect current transformers, protection devices, and secondary circuit current tests.

1000A high current generatorTechnical indicators:
| Specifications model | Rated capacity (KVA) | Rated input of the booster | Rated output of the booster | impedance Voltage% | no-load Current% | structure form | |||
| voltage regulator | Riser | current (A) | Voltage (V) | Current (KA) | voltage | ||||
| 50A | 0.5 | 0.5 | 50 | 200 | 0.05 | 5 | ∠8 | ∠6 | integrated |
| 100A | 0.5 | 0.5 | 2.5 | 200 | 0.1 | 5 | ∠8 | ∠6 | integrated |
| 200A | 1 | 1 | 5 | 200 | 0.2 | 5 | ∠8 | ∠6 | integrated |
| 300A | 3 | 3 | 15 | 200 | 0.3 | 10 | ∠8 | ∠6 | integrated |
| 500A | 2.5 | 2.5 | 12 | 200 | 0.5 | 5 | ∠8 | ∠6 | integrated |
| 600A | 3 | 3 | 15 | 200 | 0.6 | 5 | ∠8 | ∠6 | integrated |
| 1000A | 5 | 5 | 25 | 200 | 1 | 5 | ∠8 | ∠6 | integrated |
| 1250A | 7 | 7 | 35 | 200 | 1.25 | 5 | ∠8 | ∠6 | integrated |
| 1500A | 7 | 7 | 35 | 200 | 1.5 | 5 | ∠8 | ∠6 | integrated |
| 2000A | 7.5 | 7.5 | 30 | 200 | 2 | 5 | ∠8 | ∠6 | integrated |
| 2000A | 10 | 10 | 50 | 200 | 2 | 5 | ∠8 | ∠6 | split-body |
| 2500A | 12 | 12 | 60 | 200 | 2.5 | 5 | ∠8 | ∠6 | split-body |
| 3000A | 15 | 15 | 37.5 | 400 | 3 | 5 | ∠8 | ∠6 | split-body |
| 4000A | 20 | 20 | 50 | 400 | 4 | 5 | ∠8 | ∠6 | split-body |
| 5000A | 25 | 25 | 62.5 | 400 | 5 | 5 | ∠8 | ∠6 | split-body |