Welcome Customer !

Membership

Help

Shanghai Kangchenxi Industrial Development Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Shanghai Kangchenxi Industrial Development Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 0779, Building 1, 1025 Yunhe North Road, Nanqiao, Fengxian District, Shanghai

Contact Now

Oxygen sensor GPR-12-333PPM

NegotiableUpdate on 06/27
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Description: GPR-12-333 PPM O2 sensor is very suitable for measuring oxygen in gas mixtures from 0-10 PPM

Product Details

GPR-1500 series

This innovative sensor design inherits many functions of traditional thermocouple oxygen sensors, but has higher sensitivity, stability, and high signal-to-noise ratio, with a service life of 24 months, providing an effective analyzer solution for measuring low-level PPM oxygen analysis.


GPR-1100 GPR-1000 GPR-2000 GPR-3500 MO
measurement range 0-10、0-100、0-1000 ppm、0-1%、0-25% 0-1000 ppm、0-1%、0-25% 0-1%, 0-5%, 0-10%, 0-25% 0-100%
accuracy Under constant conditions, less than 2% of the selected range Under constant conditions, less than 2% of the selected range Under constant conditions, less than 2% of the selected range Under constant conditions, less than 2% of the selected range
response time T90<10 seconds T90<10 seconds T90<10 seconds T90<13 seconds
recovery time Under nitrogen purging, reach<10 ppm within 60 seconds and<1 hour in air Under nitrogen purging, the air reaches<100 ppm within 60 seconds and<15 minutes Not applicable Not applicable
Sensitivity (low-density lipoprotein) 0.05ppm 5 ppm 0.01% 0.10%
linearity <1% of the proportion <1% of the proportion <1% of the proportion <1% of the proportion
Sensor Model GPR-12-333

XLT-12-333 is suitable for gas mixtures with CO2>0.5%
GPR-12-100-M

XLT-12-100-M is suitable for gas mixtures with CO2>0.5%
GPR-11-32-RTS

XLT-11-24-RTS is suitable for gas mixtures with CO2>0.5%
GPR-11-120-RTS
Sensor lifespan at 25 ° C (77 ° F) and 1 atm Can be stored for 24 months in<1000 ppm O2 GPR-11-32-RTS in the air for 32 months
XLT-11-24-RTS 24 months in the air
GPR-11-32-RTS in the air for 32 months
XLT-11-24-RTS 24 months in the air
24 months in 100% O2
Calibration interval 30 days 30 days 30 days 30 days
inlet pressure 0.34 - 2 barg (5-30 psig), Equipped with atmospheric emission outlet 0.34 - 2 barg (5-30 psig), Equipped with atmospheric emission outlet 0.34 - 2 barg (5-30 psig), Equipped with atmospheric emission outlet 0.34 - 2 barg (5-30 psig), Equipped with atmospheric emission outlet
traffic 0.5-1.0 liters per meter (1-2 SCFH) 0.5-1.0 liters per meter (1-2 SCFH) 0.5-1.0 liters per meter (1-2 SCFH) 0.5-1.0 liters per meter (1-2 SCFH)
Gas connection 1/8 'NPT external thread quick connector 1/8 'NPT quick connector 1/8 'compression pipe joint 1/4 'compression pipe joint
Liquid receiving components stainless steel Brass connection; Stainless steel optional GP version: brass, plastic
ATEX version: Stainless steel flow casing, piping, and fittings
stainless steel
display Graphic LCD 7 x 3.5 cm (2.75 x 1.375 inches) Graphic LCD 7 x 3.5 cm (2.75 x 1.375 inches) Graphic LCD 7 x 3.5 cm (2.75 x 1.375 inches) Graphic LCD 7 x 3.5 cm (2.75 x 1.375 inches)
solve 0.01ppm 1ppm 0% 0.10%
shell Painted aluminum NEMA 4X,
10.1 x 22.9 x 7.6 centimeters (4 x 9 x 3 inches)

3.64 kilograms (8 pounds)
Painted aluminum NEMA 4X,
10.1 x 22.9 x 7.6 centimeters (4 x 9 x 3 inches)

3.64 kilograms (8 pounds)
Painted aluminum NEMA 4X,
10.1 x 22.9 x 7.6 centimeters (4 x 9 x 3 inches)

3.64 kilograms (8 pounds)
Painted aluminum NEMA 4X,
10.1 x 22.9 x 7.6 centimeters (4 x 9 x 3 inches)

3.64 kilograms (8 pounds)
compensation Air pressure and temperature Air pressure and temperature Air pressure and temperature Air pressure and temperature
signal output 0-1V 0-1V 0-1V 0-1V
LED indicator light Low battery (72 hour warning); Charging mode Low battery (72 hour warning); Charging mode Low battery (72 hour warning); Charging mode Low battery (72 hour warning); Charging mode
Operating Temperature 5 ° C to 45 ° C (41 ° F to 113 ° F) (GPR sensor),
-10 ° to 45 ° C (14 ° F to 113 ° F) (XLT sensor)
5 ° C to 45 ° C (41 ° F to 113 ° F) (GPR sensor),
-10 ° to 45 ° C (14 ° F to 113 ° F) (XLT sensor)
5 ° C to 45 ° C (41 ° F to 113 ° F) (GPR sensor),
-10 ° to 45 ° C (14 ° F to 113 ° F) (XLT sensor)
5 ° C to 45 ° C (41 ° F to 113 ° F)
power Rechargeable battery (lead-acid) Rechargeable battery (lead-acid) Rechargeable battery (lead-acid) Rechargeable battery (lead-acid)
battery life Up to 30 days of use on a single charge (40 hours of use when the pump is running) Up to 30 days of use on a single charge (40 hours of use when the pump is running) Up to 30 days of use on a single charge (40 hours of use when the pump is running) Up to 30 days of use on a single charge
Regional classification ATEX:Ex II 2 G
Ex ib IIC T4 Gb
Tamb : 5 ° C to+45 ° C
ATEX:Ex II 2 G
Ex ib IIC T4 Gb
Tamb : 5 ° C to+45 ° C
ATEX:Ex II 2 G
Ex ib IIC T4 Gb
Tamb : 5 ° C to+45 ° C
For general use only