instrumentb2bWhat are the commonly used test transformers in electrical preventive testing? What are the functions and advantages

oneInflatable test transformer

After years of effort, our company has successfully developed an inflatable lightweight test transformer. Compared with traditional oil immersed lightweight test transformers, this series of products has reduced weight by 20% -60% (depending on voltage and capacity level, dry-type test transformers above 20KVA and oil immersed test transformers are about 1.5 times heavier than inflatable ones), and have no oil pollution. They are widely used in laboratories, quality inspection departments, etc. The voltage level of a single test transformer can reach 300KV. The voltage level of insulating oil is the highest single unit, 250KV, so it is also a product in high-voltage testing. Due to the use of new production technology, the technical performance of the product has been greatly improved, and the partial discharge capacity is small. It is commonly used as a complete set of test transformers without partial discharge. Medium usage, the local volume can reach less than 3PC. Often used as the * product for testing transformers in complete voltage withstand tests without partial discharge.

2、 Product Structure:

1. The design concept, material selection, and process flow of the YDQ inflatable test transformer series products are all brand new. The widely used GIS combination cabinet features small weight, light volume, beautiful appearance, and all technical indicators meet the standard requirements, with high insulation strength.

The YDQ inflatable test transformer series products use cold-rolled DQ-151 oriented silicon steel sheets stacked into multi-stage cylindrical frame shaped iron cores, and are directly and continuously wound with QZ type wires on a specially designed high-strength insulation cylinder to form high-voltage tower coils. The outer shell is of appropriate size and filled with SF6 gas.

2. The difference between the YDQ (JZ) AC/DC inflatable test transformer product and the YDQ inflatable test transformer product lies in the clever installation of a high-voltage rectifier silicon stack inside a high-voltage sleeve, which can be transformed into a power frequency high-voltage AC output or a high-voltage DC output through the insertion and extraction of a short-circuit rod. This function can be used when conducting a DC withstand voltage test.

IIIYDQTechnical parameters of series test transformers:

Specifications

capacity

KVA

low-pressure side

high-voltage side

measurement

change

6 minutes

temperature rise

impedance

voltage

no-load

current

quality

Kg

Overall dimensions

Length x Width x Height

mm*mm*mm

voltage

V

current

A

voltage

KV

current

mA

1.5/50

1.5

200

7.5

50

30

500

50

10

<4

30

200X275X640

3/50

3

200

15

50

60

500

50

10

<4

35

240X300X690

5/50

5

200

25

50

120

500

50

10

<4

40

250X355X710

10/50

10

200

50

50

200

500

50

10

<4

60

260H375H750

15/50

15

400

37.5

50

300

500

50

8

<4

70

270H420H800

20/50

20

400

50

50

400

500

50

8

<4

85

285H440H820

30/50

30

400

75

50

600

500

50

8

<4

100

295H386H840

50/50

50

400

125

50

1000

500

50

8

<4

120

320H416H910

10/100

10

200

50

100

100

1000

50

10

<4

65

350H475H1300

15/100

15

400

37.5

100

150

1000

50

8

<4

85

510H390H1320

20/100

20

400

50

100

200

1000

50

8

<4

100

540H400H1340

30/100

30

400

75

100

300

1000

50

8

<4

110

560H410H1360

50/100

50

400

125

100

500

1000

50

8

<4

125

600H460H1410

10/150

10

200

50

100

66.7

1500

50

10

<4

90

265H380H1750

15/150

15

400

37.5

150

100

1500

50

8

<4

100

510H390H1800

20/150

30

400

50

150

133

1500

50

8

<4

110

540H415H1800

30/150

30

400

75

150

200

1500

50

8

<4

125

560H430H1800

50/150

50

400

125

150

333

1500

50

8

<4

140

640H490H1850

YD Oil Immersed Series Test Transformer

Oil immersed test transformer is a basic testing equipment for users such as power plants, power supply and distribution systems, and scientific research institutions. It is used to conduct insulation strength tests on various electrical products, electrical components, insulation materials, etc. under specified voltages, assess the insulation level of the products, discover insulation defects of the tested products, and measure the ability to withstand overvoltage. Oil immersed test transformer is the prototype of * type test transformer. Zui ancient equipment is also a product that does not need to be updated but never lags behind.

II. Structure

The iron core of this series of products is a single-phase core type, made of cold-rolled oriented silicon steel sheets stacked together, and the fastening method uses steel as a clamp. The high-voltage coil is a cylindrical multi-layer tower, made of polyester enameled wire and high voltage insulation material wound around it. The low-voltage coil is located outside, and the instrument coil is an independent winding, generally 100V. The shell is octagonal, and test transformers above 10KVA are equipped with movable iron wheels. It has the characteristics of light weight, small size, easy mobility, and excellent performance.

3、 Technical parameters

Test transformer parameters:

Specifications

capacity

KVA

low-pressure side

high-voltage side

60 minute temperature rise ℃

Impedance voltage%

no-load current

quality

kg

Overall dimensions

Length x Width x Height

mmmmmmmmmm

voltage

V

current

A

Voltage KV

current

mA

1.5/50

1.5

200

7.5

30

500

50

10

<4

19.5

200X275X640

3/50

3

200

15

60

500

50

10

<4

27

240X300X690

5/50

5

200

25

100

500

50

10

<4

52

250X355X710

10/50

10

200

50

200

500

50

10

<4

80

260H375H750

15/50

15

400

37.5

300

500

50

8

<4

120

270H420H800

20/50

20

400

50

400

500

50

8

<4

140

285H440H820

30/50

30

400

75

600

500

50

8

<4

155

295H386H840

50/50

50

400

125

1000

500

50

8

<4

184

320H416H910

10/100

10

200

50

100

1000

50

10

<4

135

350H475H1300

15/100

15

400

37.5

150

1000

50

8

<4

150

510H390H1320

20/100

20

400

50

200

1000

50

8

<4

215

540H400H1340

30/100

30

400

75

300

1000

50

8

<4

250

560H410H1360

50/100

50

400

125

500

1000

50

8

<4

290

600H460H1410

10/150

10

200

50

66.7

1500

50

10

<4

180

265H380H1750

15/150

15

400

37.5

100

1500

50

8

<4

200

510H390H1800

20/150

30

400

50

133.3

1500

50

8

<4

220

540H415H1800

30/150

30

400

75

200

1500

50

8

<4

280

560H430H1800

50/150

50

400

125

333.3

1500

50

8

<4

340

640H490H1850

One Product Introduction

Dry type test transformers are suitable for on-site testing of power systems and various power users. They are small in size and convenient for various on-site tests.

II Product Features

Dry type test transformer is an improved product of Huading Power based on YD oil immersed test transformer. It introduces * technology, and the coil is vacuum cast with epoxy resin, which is small in size, lighter in weight, stable in performance, easy to carry, and effectively reduces leakage magnetic field, improves insulation strength and moisture resistance.

III Technical Indicators:

1. Impedance voltage: 4.5% -8%

2. Output voltage waveform: sine wave

3. Surface temperature rise: < 55 ℃

4. No load loss: 0.2% -0.35%

5. Allow continuous operation time: 2 hours

6. Intermittent operation time: Continuous

Main technical parameters:

Specification Model

capacity

(KVA)

Input voltage (V)

Output voltage (kV)

output current

(mA)

Output DC high voltage (KV)

The largest external size

(mm)

weight

(Kg)

GTB-1.5/50

1.5

200

50

30

70

250×200×370

20

GTB-3/50

3

60

270×220×370

27

GTB-5/50

5

100

300×270×490

48

GTB-10/50

10

200

380×290×500

68

GTB-15/50

15

300

380×290×800

78

GTB-20/50

20

400

380×290×800

82

GTB-2/100

2

100

20

140

300×270×560

52

GTB-5/100

5

60

380×290×800

76

GTB-10/100

10

100

380×290×1000

80

GTB-15/100

15

150

380×290×1000

90

DC technical parameters:

The parameters of the AC/DC dual-purpose test transformer are as shown in the table above. The rated DC voltage in the DC parameters is 1.4 times the AC voltage, and the rated DC current is 0.7 times the AC current.